SESPM1040-541-LT-xx Install Guide 1. Product Description The Lantronix SESPM1040-541-LT-xx Switch is a Layer 2 managed switch with (4) 10/100/1000Base-T PoE++ (IEEE 802.3bt) ports and (1) combination 10/100/1000Base-T RJ-45 or 100/1000Base-X SFP uplink port (additional optional ports available), that is ideal for use in security and surveillance, PoE lighting, digital signage and many other applications.
Fiber Management Kit; includes fiber management tray and alternative cable SESPM-4P-FMK gland / inserts. Lantronix offers a full line of small form factor pluggable (SFP) modules. See our Industrial SFP Modules Hardened SFP webpage for more information.
Lantronix SESPM1040-541-LT-xx Install Guide Specification Description -PD Unit: 821,303 hours (Telcordia) Warranty 2 Years NFC Flex Stamp Antenna Specifications The antenna is a small flexible Near Field Communication (NFC) antenna built in to the inside of the front cover (shown below). It is based on well-known antenna concepts and reliable technology, and it is RoHS compliant.
Lantronix SESPM1040-541-LT-xx Install Guide Feature Benefits Feature Benefit Saves time and labor expense by allowing laborers of any skill level to easily Integrated NFC configure switch prior to powering up and to repeat the configuration across multiple switches. Allows remote access to switch for troubleshooting and changing settings, Integrated BLE Radio reducing time and hassles related to console cables and ladders or scissor lifts.
Page 11
Lantronix SESPM1040-541-LT-xx Install Guide Feature Benefit Provides RADIUS Client enable/disable and configuration of 1-4 Radius Servers RADIUS for authentication purposes. Provides TACACS+ Client enable/disable and configuration of 1-4 TACACS+ TACACS+ Servers for authentication purposes. Secure Shell (SSH) cryptographic network protocol allows setup of Host and...
SESPM-2P-24V-CP Option Quick Start Guide, 33832 Release Notes (version specific) For More Information A printed Quick Start Guide is shipped with each unit. For Lantronix Drivers, Firmware, Manuals, Product Notifications, Warranty Policy & Procedures, etc. go to the Lantronix Technical Resource Center.
Lantronix SESPM1040-541-LT-xx Install Guide 2. Switch Installation This chapter provides system requirements, package contents, Cautions and Warnings, pre-installation and Installation Guidelines, Hardware Install Procedures, Cabling, Grounding, Bonding, and Surge protection information. The information applies to the SESPM1040-541-LT-AC, -DC, and -PD. Differences are noted where they apply.
Lantronix SESPM1040-541-LT-xx Install Guide Cautions and Warnings Cautions indicate that there is the possibility of poor equipment performance or potential damage to the equipment. Warnings indicate that there is the possibility of injury to person. Cautions and Warnings appear here and may appear throughout this manual where appropriate.
Lantronix SESPM1040-541-LT-xx Install Guide Warnings - PoE ++ Family This section includes information specifically for installations in hazardous environments. We recommend performing a preliminary configuration of the switch before it is installed in a permanent location. Pre-Installation Warnings: These warnings are translated into multiple languages in the Regulatory Compliance and Safety Information for this switch.
Nuclear Facilities, Aircraft Navigation or Aircraft Communication Systems, Air Traffic Control, Life Support, or Weapons Systems ("High Risk Activities"). Lantronix and its supplier(s) specifically disclaim any expressed or implied warranty of fitness for such High Risk Activities.
Lantronix SESPM1040-541-LT-xx Install Guide Safety and Labeling info from IEEE 802.3bt Standard PoE Modes, Compliance, Standards and Troubleshooting on page for Safety and Labeling info from Approved Standard for Ethernet Amendment 2: Power over Ethernet over 4 Pairs (IEEE 802.3bt) (below).
Lantronix SESPM1040-541-LT-xx Install Guide Electrical Safety Warnings Electrical Safety IMPORTANT: This equipment must be installed in accordance with safety precautions. Elektrische Sicherheit WICHTIG: Für die Installation dieses Gerätes ist die Einhaltung von Sicherheitsvorkehrungen erforderlich. Elektrisk sikkerhed VIGTIGT: Dette udstyr skal installeres i overensstemmelse med sikkerhedsadvarslerne.
Lantronix SESPM1040-541-LT-xx Install Guide Surge Protection / Grounding and Bonding Surge Protection Security cameras can act as lightning rods, drawing the voltage through the copper cabling to the networking equipment. If a lightning strike hits within a few hundred feet of a cable, it can produce thousands of volts and several million watts.
Lantronix SESPM1040-541-LT-xx Install Guide Grounding Wire Attachment Warning: For ALL versions, connect a ground wire to the Ground Post in upper right corner of the enclosure. 1. Connect one end of an 18 gauge or greater ground wire to the grounding post using two 5/16” washer/nuts.
Lantronix SESPM1040-541-LT-xx Install Guide Hardware Install Procedures All three switch models have the same hardware mounting procedures. Wall Mount Installation 1. Place unit at desired location and secure with mounting screws (not included). 2. Ground the switch before connecting other cables.
Lantronix SESPM1040-541-LT-xx Install Guide Cable and Cabling • The 802.3bt standard allows Cat 5e for 60W but requires Cat 6 cable for 90W. You can use Category 5e or 6A cable, but remember: • o Cat 6A has larger bundle sizes, o Cat 6A can go longer reaches with PoE, and o Category 6A is 4.3 W more efficient per link.
Lantronix SESPM1040-541-LT-xx Install Guide Wire Gland Plug Kit Various wire gland inserts are provided. To maintain NEMA/IP rating and Switch warranty, be sure to use the most appropriately sized insert for your cable and fill all unused holes with the hole plugs provided.
Page 29
Lantronix SESPM1040-541-LT-xx Install Guide Note: Split gland is easiest to use. Press finger or tool through and press split gland out. Note: Install cabling before connecting power. Note: Try to keep the switch out of direct sunlight and try to maximize space around switch to maximize air flow.
Lantronix SESPM1040-541-LT-xx Install Guide To insert cables through the wire glands: The 2-hole wire gland will support up to 7mm diameter cables. (If using fiber, the optional fiber management kit comes with replacement wire glands to accommodate fiber cables.) A pre-terminated patch cord can be used with the wire glands. Here are the suggested installation steps: •...
Lantronix SESPM1040-541-LT-xx Install Guide Port Configuration Ports 1-4 are 10/100/1000Base-T PoE++ PSE Ports. Port 5 is a combo 10/100/1000Base-T or a 100/1000Base-X uplink port. On the -AC and -DC version, it can either be used as a copper or fiber port. However, on the -PD version, it is normally used for PoE power input, in which...
Lantronix SESPM1040-541-LT-xx Install Guide There are temperature sensors within the switch to monitor the temperature inside the switch. If the power supply within the switch gets too hot, all ports will be shut down regardless of priority. This is to prevent the switch from overheating and causing permanent damage.
Note: The SFP ports must use industrial-rated optical transceiver product, Rated 3.3Vdc, Laser Class 1. See the SFP manual for specific Cautions, Warnings, and instructions. Industrial SFP Modules: Lantronix offers a full line of small form factor pluggable (SFP) modules. Industrial rated models must be used for outdoor switch installation. See Lantronix...
Lantronix SESPM1040-541-LT-xx Install Guide SFP Removal Caution: Be careful when removing the SFP from a device. Some SFP transceiver module temperatures may exceed 160°F (70°C) and be too hot to touch with bare hands. Note: Do not remove and replace the SFP modules more often than necessary;...
Page 35
Lantronix SESPM1040-541-LT-xx Install Guide default-config as the startup-config. With access to the system restored, you can execute those tasks when desired. The following messages will appear on the user console (note that there will be a delay before the last line appears while the factory settings are applied to the system): System Button pressed...
Lantronix SESPM1040-541-LT-xx Install Guide 3. Applying Power Power Connection Descriptions Each of the three switch models has different procedures for applying power. SESPM1040-541-LT-AC-xx: AC-powered power source (PSE) provides up to 90 Watts on individual ports (specific port configuration may apply), not to exceed 180 Watts total.
Page 37
Lantronix SESPM1040-541-LT-xx Install Guide AC Power Cord Specifications Ratings: Voltage: 300 VAC. Temperature: 105 deg. C. Flame Rating: VW-1. Conductor: Wire Size: 18-AWG. Number: 3-Conductor. Material: Bare Copper. Stranding: 41/0.16 mm. Insulator: Material: PVC. Color: White, Black, Green/Yellow. Nominal Thickness: 0.38 mm. Outer Diameter: 2.0 mm.
Lantronix SESPM1040-541-LT-xx Install Guide Configuration Procedures There are several ways to configure the SESPM1040-541-LT-xx: using NFC (the easiest way), Web UI, or CLI. NFC Pre-Configuration (Configuring the Switch Directly in the Box) After you verify the contents of the box, you can configure the switch directly in the box and unpack the box contents later at the install location.
Lantronix SESPM1040-541-LT-xx Install Guide Power Connection Procedures -AC Version Plug into approved AC outlet using supplied AC power cord. If the application calls for routing through conduit or hard wiring, the AC plug can be cut off of the supplied cord and hard wired into junction box (if code allows).
Page 40
• Power over the copper • Powering a -PD from a Standalone DC Power Supply: Several Lantronix Standalone DC Power Supplies are available (order separately).You can use any standalone power supply that meets the -PD power requirements; Specifications on page 7.
Page 41
Lantronix SESPM1040-541-LT-xx Install Guide 2. Powering a -PD (beyond 100m) 2a. Powering a -PD (beyond 100m) from -AC or -DC using Parallel Copper/Fiber (Composite) Cable Page 41 of 64 33772 Rev. F https://www.lantronix.com/...
Lantronix SESPM1040-541-LT-xx Install Guide 2b. Powering a -PD (beyond 100m) from one external power source using parallel copper/fiber (Composite) cable Composite Fiber For parallel fiber and copper power cable applications, grounding is done the same as for the -DC version;...
Lantronix SESPM1040-541-LT-xx Install Guide LED Locations The LEDs on the SESPM1040-541-LT-xx switch board are shown below. LED Descriptions LEDs are provided to report PoE activity, link activity, system readiness, and switch power and BLE pairing information as shown and described below.
Lantronix SESPM1040-541-LT-xx Install Guide 3. Link Activity: amber LEDs from top to bottom: Port 1: off = no activity; on = link activity. 2: off = no activity; on = link activity. 3: off = no activity; on = link activity.
A3. The IEEE802.3bt standard has an Annex Clause 145.3.8.2.1 for input average power exceptions. In closed systems (e.g., one in which a Lantronix’ SESPM1040-541-LT-AC or –DC version switch is providing power to Lantronix’ SESPM1040-541-LT-PD switch, this clause allows the -PD to determine resistance and draw power up to, but not exceeding, the amount the PSE puts out.
Page 46
Lantronix SESPM1040-541-LT-xx Install Guide smartphone or tablet even after it moves out of proximity, and the configuration is transferred into the switch’s memory once the switch is fully powered up. Q9. What does the BLE feature do? A9. The Bluetooth Low Energy feature allows remote access to the switch without having to physically connect with a cable, so monitoring and troubleshooting and changes can be made prior to leaving the job site or after ladders or scissor lifts have been removed.
Lantronix SESPM1040-541-LT-xx Install Guide Q18: Can the wire glands be changed? A18: To maintain NEMA/IP rating and Switch warranty, use the wire glands and inserts provided with the Switch, use the most appropriately sized insert for your cable type, and make sure to fill all unused holes with the hole plugs provided.
Lantronix SESPM1040-541-LT-xx Install Guide PoE Troubleshooting 1. Get as much detail as possible regarding the symptom, including any system messages from the PoE switch. For example, does a PD not power up at all, or does it power up briefly and then power down? 2.
Lantronix SESPM1040-541-LT-xx Install Guide NFC Troubleshooting Check if you have NFC. Not all phones and tablets have NFC. Check your phone’s Settings menu: 1. On your Android device, tap on Settings. 2. Tap More. 3. Scroll down and you should see NFC and Android Beam options.
Lantronix SESPM1040-541-LT-xx Install Guide PoE Modes, Compliance, Standards and Troubleshooting The switch is a Type 4 device (Class 8) that supports IEEE 802.3af/at/bt Power-over-Ethernet. PoE History PoE first emerged to solve the problem of powering Voice over Internet Protocol (VoIP) phones. PoE gained momentum in 2001 and 2002, when WAP makers, and other manufacturers took advantage of the technique.
PoE Type 4 can support devices such as laptops and TVs. Related Information See the IEEE 802.3bz standard at http://standards.ieee.org/getieee802/download/802.3bz-2016.pdf. Note that this manual provides links to third part web sites for which Lantronix is not responsible. Page 51 of 64 33772 Rev. F...
Lantronix SESPM1040-541-LT-xx Install Guide Requesting and Sourcing Power Type and Class of PoE Device: PoE Classes PoE Classification is where the PSE detects the PD’s power requirements by using Physical Layer Classification or LLDP. The IEEE 802.3bt standard specifies mutual identification to address four-pair operation. Additional...
• 802.3af/at “compatible” PDs typically can provide power using only Mode B. Typical PD Power Requirements 1.8 Watts: Lantronix’ M/GE-ISW-SFP-01-PD (Class 1 Powered Device (0.44 Watts – 3.84 Watts). • 13W: IP Camera, VoIP Phone, Wireless Access Point, Networked Audio.
Lantronix SESPM1040-541-LT-xx Install Guide PoE ++ Connectivity, Arcing, and Temperature Issues • PoE is not live until powered device (PD) and powered sourcing equipment (PSE) handshake. • When unplugging live PoE, an arc (or spark) occurs between plug and jack contacts.
Lantronix SESPM1040-541-LT-xx Install Guide Network Safety This subclause sets forth a number of recommendations and guidelines related to safety concerns. The list is neither complete nor does it address all possible safety issues. The designer is urged to consult the relevant local, national, and international safety regulations to verify compliance with the appropriate requirements.
Lantronix SESPM1040-541-LT-xx Install Guide Backward Compatibility Although new features were added, higher power is supported and some algorithms were changed to ensure interoperability. The idea is that the system will work with legacy Type 1 and Type 2 devices. It should work automatically, as long as the PSE is capable (in terms of power) of supporting the PD and both are standard compliant.
Lantronix SESPM1040-541-LT-xx Install Guide Compliance Information Declaration of Conformity Manufacture’s Name : Lantronix, Inc. Manufacture’s Address : 48 Discovery, Suite 250, Irvine, CA 92618 U.S.A. Declares that the Power++ Solutions family of products: SESPM1040-541-LT-AC, SESPM1040-541-LT-DC, SESPM1040-541-LT-PD Conforms to the following Product Regulations: EN 55022:2010;...
Lantronix SESPM1040-541-LT-xx Install Guide whether the equipment otherwise complies with the rules in this part, the operator of ISM equipment that causes harmful interference to any authorized radio service shall promptly take whatever steps may be necessary to eliminate the interference.
Page 59
Lantronix SESPM1040-541-LT-xx Install Guide PCB Hardware Revision label (example only) Page 59 of 64 33772 Rev. F https://www.lantronix.com/...
Describe any action(s) already taken to resolve the problem (e.g., changing mode, rebooting, etc.): ________________ ________________________________________________________________________________________________________________________ ________________________________________________________________________________________________________________________ ________________________________________________________________________________________________________________________ The model and serial numbers of other Lantronix devices in the network: _____________________________ ________________________________________________________________________________________________________________________ ________________________________________________________________________________________________________________________ Describe your network environment (layout, cable type, etc.): ________________________________________________________...
Lantronix SESPM1040-541-LT-xx Install Guide Glossary of Terms Note that the mention or definition of a term here does not imply that the switch supports that particular feature. 802.11b standard has a maximum raw data rate of 11 Mbit/s and uses the same media access method defined in the original standard.
Page 62
Lantronix SESPM1040-541-LT-xx Install Guide protection of enclosed equipment from foreign bodies. The second defines the protection level that the enclosure enjoys from various forms of moisture (drips, sprays, submersion etc.). IP66 Enclosure = IP rated as “dust tight” and protected against heavy seas or powerful jets of water. These enclosures are constructed for indoor or outdoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment;...
Page 63
Lantronix SESPM1040-541-LT-xx Install Guide RP-SMA (Reverse Polarity SMA) is a variation of the SMA connector which reverses the gender of the interface. The term “reverse polarity” refers only to the gender of the connector’s contact pin and not to the signal polarity.
Page 64
Toll Free: 800-526-8766 Phone: 949-453-3990 Fax: 949-453-3995 Technical Support Online: https://www.lantronix.com/technical-support/ Sales Offices For a current list of our domestic and international sales offices, go to the Lantronix web site at www.lantronix.com/about/contact. Page 64 of 64 33772 Rev. F https://www.lantronix.com/...
Need help?
Do you have a question about the SESPM1040-541-LT Series and is the answer not in the manual?
Questions and answers