4,1
Service Total Disable
Service Driver Disable
Service Total Expired
Service Driver Expired
Battery Over voltage
4,2
Battery Under voltage
4,3
Temperature Cutback
4,4
Anti Tie down
5,1
Hardware Failure
5,2
Software Failure
5,3
Parameters Corrupt
Total KSI time up (stop running) Total KSI time up
Total driving time up (stop
running)
Set (KSI) service time up
Set (driving) service time up
Battery overvoltage
Battery under voltage
Over temp or under temp
Mode switch already closed
when truck starts
Hardware self check failure
Software self check failure
Parameter storage error
Total driving time up (stop running)
Set (KSI) service time up
Set (driving) service time up
Battery overvoltage
1 Battery under voltage
2 Loose battery terminal
3 Battery damaged
1 Controller power too small
2 Truck overloaded for extended period
3 Bad dissipating condition
1 Mode switch welded
2 Switch in M2 position
Controller damaged
Controller damaged
Controller damaged