Note!
Customers can select the mode according to their usage requirements.
2.2

Dual Auto-Shutdown Modes

Installation Procedures
Time to shut
down PC after
power outage
Settings
Time to turn-off
IPS after shut-
down command
Operating System
Compatible Products
Accessories
Advantages
*In max. power mode, the PPC-IPS module optimizes power consumption to support a maxi-
mum length of time based on the remaining battery capacity.
SW Utility via RS-232
Connect the PPC-IPS
module to the PPC
device using a RS-232
cable
Install SW utility
Configure the timing
and shutdown mode (S4
or S5) settings in the
SW utility (refer to
Chapter 4.2)
5~ 360 seconds (per second)
1~ 9 minutes (per minute)
Windows 10, XP, 7, 8, and 8.1 Windows 7, 8, 8.1, and Linux
The standard software utility
is only available for PPC
series systems, but can be
customized for other devices
upon request
RS-232 cable
Time ranges can be
configured
Supports max. power
mode*
Status monitoring
7
HW via PS_ON
Connect the PPC-IPS mod-
ule to the PPC device using
a PS_ON cable
Set the time switch on the
PPC-IPS module (see Fig.
2.2, item E)
Configure the shutdown
mode (S4 or S5) in the OS
(refer to Chapter 3.2)
30 or 360 seconds
(set via external switch)
Not supported
Only available for PPC series
systems
PS_ON cable
Plug-and-play functionality
No software installation
No RS-232 port required
PPC-IPS User Manual