21
Connecting a PTZ Camera (DNR400 Series)
2. Connect RS485 cables from the camera to the A (+) and B (-) ports on the NVR.
3. Right-click and click Main Menu. Enter the system user name (default: admin) and
password (default: 000000) if prompted.
4. Click
>Setting>Pan/Tilt/Zoom.
5. Under Channel, select the channel your PTZ camera is connected to.
6. Under PTZ Type, select Local. This allows the system to control the PTZ functions
over RS485. Configure the following RS485 connection parameters for your camera:
• Protocol.
• Address.
• Baud Rate.
• Data Bit.
• Stop Bit.
• Parity.
Note
Check the instruction manual for your PTZ camera to determine the correct settings.
7. Click OK. You can now control your PTZ camera using the system.

21.1 Controlling a PTZ Camera (Local NVR)

1. In Live View, double-click the channel that has the PTZ camera connected to open in
full-screen.