Backhaul FM4200 Mobi
Cisco Ultra-Reliable Wireless
2. To do the reset using FM Racer, refer to the Fluidmesh Networks
FM Racer User Manual.
3. To do the reset by physically accessing the unit, follow the
procedure below.
To reset the radio to its factory default settings, do the steps that follow:
1.
Power ON the unit.
2.
Wait approximately 40 seconds for the unit to boot up.
3.
When the unit has completed its boot sequence, press the
RESET button for 7 seconds.
• The LEDs will blink.
• The unit will be restored to factory default settings
• The unit will reboot.
• The administrator user name and password will both be

5.1.5. Suitability for outdoor installation

The Cisco FM4200 Mobi was specifically designed for installation in harsh
outdoor environments. Under operating conditions, the unit is completely
sealed, and is capable of high-performance operation in outdoor
environments, and under severe conditions such as water spray, salt, and
extreme fluctuations in cold and heat.
The Cisco FM4200 Mobi has successfully passed stringent environmental
certification tests, including European Committee for Standardization
50155
(electronic equipment used on rolling stock for railway applications)
and
EN 45545
Examples of specific certification tests included:
• Verification of resistance to salt water intrusion and corrosion. This
consisted of subjecting the unit to running, high-pressure salt water
for 24 hours, followed by a 24-hour drying time. The unit was then
carefully examined to verify that no corrosion or water ingress were
found.
• Verification of resistance to fluctuating temperatures. This consisted
of placing the unit in a climatic chamber and subjecting it to
operating ranges between -40°C and 80°C, for four hours.
© 2020 Cisco and/or its affiliates. All rights reserved.
(including its default IP address of 192.168.0.10 and
subnet mask of 255.255.255.0).
reset to admin.
(fire protection on railway vehicles) tests.