F Error Codes - Fetco CBS-1241 Users Manual And Operator Instructions

Extractor plus brewing system
Table of Contents

Advertisement

F Error Codes

DO NOT CLEAR ERROR CODES UNTIL ERROR IS IDENTIFIED AND CORRECTED
Contact factory or specialized personnel for error codes
Code
Description
Software error-error on start up or
001
corrupted software
Internal flash corrupted
002
internal data memory malfunction
050
Short-circuit in temperature probe
051
Open temperature probe.
Initial Fill Error.
100
Initial fill time took longer than
expected after powering up.
Error on refill-.
101
Tank did not refill within expected time.
200
Heating flatline-Tank is boiling
Heater open, high limit thermostat, or
201
Solid State Relay (SSR) fault
202
Heater Shorted or Stuck SSR
255
Keyboard [HID] error
NO
BSKT
Insert Brew Basket
Go to fetco.com for the latest versions of all information
Possible Cause
Improper start-up or
shutdown
Error found in
cyclic
redundancy check CRC
Probe failure.
Bad probe connection, or
probe failure.
Water supply flow rate is
too low.
Water supply flow rate is
too low.
Heater is on, temperature is
not rising/dropping
Failure of heating element,
SSR, high limit
Heater is off and heating
SSR is stuck "ON"
Usually from longer than 10
se contact. Or faulty
reassembly after service
Brew basket must be in
place
This is a
SAFETY FEATURE
User Guide & Operator instructions
Page 12
Corrective Action
Restart , if still fault: reload software
Restart , if still fault: reload software
If not corrected :replace board
Replace probe.
Check all connections. Replace probe if
necessary.
Watch for short potting during brew
cycle. Investigate cause of low flow rate.
(Clogged water filter...)
Watch for short potting during brew
cycle. Investigate cause of low flow rate.
(Clogged water filter...)
High elevation correction. Bad heaters
or temperature probe or position
Check and replace heating elements,
SSRs, high limit devices if necessary.
Check ohms on heater (15-60Ω). SSR
may be stuck in ON mode-replace SSR.
Restart , if still fault: reload software. If
mechanical: replace module
Insert brew basket into brewer rails to
enable brewer
P212e0August 2021