A Program - Fetco CBS-1241 Users Manual And Operator Instructions

Extractor plus brewing system
Table of Contents

Advertisement

A Program

The settings below are shown for the top batch on a single brewer top left button on a twin brewer.
See how to access all A menus on the previous page. Below are the brew settings for default A1 & A2 batches
POSITION
Program Items
A1.10
Batch Volume
A1.20
Brew Time
A1.30
Prewet Perc.
Prewet Delay
A1.40
(Pause after prewet
completes)
A1.60
This is a
Drip Delay
Safety
Feature
BATCH
A2.00
ENABLED
A2.10
Batch Volume
A2.20
Brew Time
A2.30
Prewet Perc.
Prewet Delay
A2.40
(Brew pause after
prewet completes)
A2.60
Drip Delay
Safety
Feature
Batch Enabled
A30 YES -
A30
NO +
Batch
Copy From Batch
Copy
Copy To Batch?
Single Topmost Batch cannot be disabled. TWIN Topmost Batch LEFT & RIGHT cannot be disabled.
Middle and bottom batches may be disabled for single and twin brewer (CBS-1241 and CBS-1242 )
† DRIP DELAY will not activate when STOP is pressed within 5 seconds of starting a brew time
.
RECIPE Location map
Viewing and changing settings for the brew
recipes is from the "A" screens with the controls in
PROGRAMMING.
The uppermost button positions are permanent
and will not display programming step A_0. The
table above shows in position A20 that a button
position can be made active or inactive.
Position A1 does not display this step
Go to fetco.com for the latest versions of all information
Menu Features: Batch Parameters
Factory set Default Programming Range Increments
1 gal
0.25 to 1.25 gal
3.8 L
0.95 to 4.75L
4:00 minutes
2:00 – 12:00
0%
0.00 – 25.0%
0% [1:00 Min]
[0:10 – 5:00]
1:30 mm:ss
0:30 – 6:00 Min.
YES
Middle and Bottom
(Active)
batches A2,3,5,6
0.75gal
0.25 to 1.25 gal
2.90L
0.95 to 4.75L
3:30 minutes
2:00 – 12:00
0%
0.00 – 25.0%
0% [1:00 Min]
[0:10 – 5:00]
1:30 mm:ss
0:30 – 6:00 Min.
NO-inactive
Middle and Bottom
(defaults to recipe
batches A2,A3
A20 if activated)
A90
A91
Single Side Models
CBS-1241 Plus
STOP
0.01G
0.05L
0.30
1%
1:00 min
Batch on or
off
0.01G
0.05L
0.30
1%
1:00 min
Batch
on or off
A90 1 (1-6)
A91.1 (1-6)
DISPLAY
STOP
BATCH A1
(permanent)
BATCH A2
(enabled by factory)
BATCH A3
(disabled by factory)
User Guide & Operator instructions
Page 7
Notes
Default total brew time is
5:30 minutes
Percentage of total brew
volume
The time between
prewetting and start of
brew cycle.
This feature appears
ONLY if Prewet >0:00
Time that brew basket
remains locked during final
drip-out
Drip delay remains "ON"
for 1:30 minutes if STOP
is pressed during brew†
Batches may be
individually enabled,
rewritten or deactivated
Default total brew time is
5:30 minutes
Percentage of total brew
volume
The time between
prewetting and start of
brew cycle.
This feature appears
ONLY if Prewet >0:00
Time that brew basket
remains locked during final
drip-out
Batches may be
individually enabled,
rewritten or deactivated
DISPLAY
Dual Side Models
CBS-1242 Plus
STOP
STOP
STOP
BATCH A4
(permanent)
BATCH A5
(enabled by factory)
BATCH A6
(disabled by factory)
P212e0August 2021

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cbs-1242

Table of Contents