Bosch API-AMC2-4WE Installation Manual

Access modular controller 2
Hide thumbs Also See for API-AMC2-4WE:

Advertisement

Quick Links

Access Modular Controller 2
API‑AMC2‑4WE | ADS‑AMC2‑4WE
en
Installation manual

Advertisement

Table of Contents
loading

Summary of Contents for Bosch API-AMC2-4WE

  • Page 1 Access Modular Controller 2 API‑AMC2‑4WE | ADS‑AMC2‑4WE Installation manual...
  • Page 3: Table Of Contents

    RS-485 for extension modules Wiegand Interface for Card Readers 4.10 Connecting Relay Outputs 4.11 Connecting Analog Input Devices 4.12 Tamper Protection Operating Status Display of the AMC2 Technical Data Appendices Connecting Diagrams Index Bosch Access Systems B.V. Installation manual 2020-01 | V02 |...
  • Page 4: Safety Instructions

    10. Lightning - For added protection during electrical storms external lightning conductors can be installed. This prevents power surges from damaging the unit. 11. The units should be installed in locations with restricted access. 2020-01 | V02 | Installation manual Bosch Access Systems B.V.
  • Page 5: Safety Precautions

    0°C to 50°C. Disposal Your Bosch product is designed and manufactured with high-quality materials and components which can be recycled and reused. This symbol means that electrical and electronic equipment, at their end-of-life, should be disposed of separately from your household waste.
  • Page 6: Unpacking

    Do not attempt to put the unit into operation if components are damaged. If any parts are missing, inform your customer service representative or a Bosch Security Systems salesperson. The shipping carton is the safest transport container for the unit. Store it and the other packaging material for future use.
  • Page 7: Important Information

    Bosch Security Systems retains all rights not expressly granted. Nothing in this license constitutes a waiver of Bosch’s rights under the U.S. Copyright laws or any other federal or state law. If you have any questions concerning this license, please, write to:...
  • Page 8: Introduction

    The signal settings and parametrization of the readers connected to the extension module, are carried out by the configuration applications in the access control system and by the AMC2-4W to which it belongs. 2020-01 | V02 | Installation manual Bosch Access Systems B.V.
  • Page 9: Equipment Configuration

    Jumper for setting either voltage free relay output (“dry” mode) or looped-in voltage from the AMC2 internal power supply (“wet” mode). Jumper: Equalization of potential between different systems and earth ground (shield) for the extension interface. Bosch Access Systems B.V. Installation manual 2020-01 | V02 |...
  • Page 10: Performance Characteristics

    Tamper contact for external covers Notice! If an external power supply is used, this should also guarantee an uninterruptable power supply (UPS). Example: Bosch power supply APS-PSU-60 (F.01U.282.970). System Overview The AMC2-4WE is connected between the access controller AMC2-4W and the various peripheral devices.
  • Page 11 Using Wiegand reader interfaces, up to four peripheral devices can be connected to each AMC2-4R4. The interfaces are point-to-point connections, meaning that only one reader can be connected to one interface. Bosch Access Systems B.V. Installation manual 2020-01 | V02 |...
  • Page 12: Installing

    Attach the AMC2-4R4 into the upper edge of the mounting rail [1], then push down the device and snap it onto the rail by pushing it towards the back [2]. Figure 4.1: Mounting the AMC2 device on a mounting rail 2020-01 | V02 | Installation manual Bosch Access Systems B.V.
  • Page 13: Unmounting

    Push down the AMC2-4R4 until the lower edge snaps out of the mounting rail [1]. Pull the lower end of the AMC2-4R4 from the mounting rail [2]. Figure 4.2: Unmounting the AMC2 device from a mounting rail Bosch Access Systems B.V. Installation manual 2020-01 | V02 |...
  • Page 14: Opening The Case

    The AMC2-4R4 case consists of a top cover mounted with a two-point snap-in closure on a chassis. To open the case, push down the two snap-ins with a screwdriver, then swing the cover down. Figure 4.3: Opening the AMC2-4WE case 2020-01 | V02 | Installation manual Bosch Access Systems B.V.
  • Page 15: Closing The Case

    [1]. Please ensure that the BOSCH logo is not upside-down. The upper edge of the front cover now aligns with the two-point snap-in closures on the upper edge of the back cover [2], and may thus be clicked gently into place.
  • Page 16 These specifications apply to power supply, readers, relay outputs, and extension interface. Regarding inputs, specific voltage-drop values need to be taken into account. Refer to Connecting Analog Input Devices, page 26. 2020-01 | V02 | Installation manual Bosch Access Systems B.V.
  • Page 17: Grounding And Shielding

    Jumper connects the internal ground of the AMC2-4R4 to the ground of the RS-485 slave interface. Set Jumper A2 only at the first AMC2-4R4 of a party line Overview - Power supply/ consumption, page 19. Bosch Access Systems B.V. Installation manual 2020-01 | V02 |...
  • Page 18: Connecting Power Supply

    The power can also be supplied by the AMC2-4W. In this case power pins 1 and 2 should be connected, as well as data lines on pins 3 - 6. 2020-01 | V02 | Installation manual Bosch Access Systems B.V.
  • Page 19: Overview - Power Supply/Consumption

    Figure 4.7: Interface for internal power supply 4.7.3 Overview - Power supply/consumption Figure 4.8: Example configurations = AMC2-4WE = AMC2 I/O Extension board line = Power supply broken line = Data line Bosch Access Systems B.V. Installation manual 2020-01 | V02 |...
  • Page 20 AMC2 itself . This leaves 55VA to support external devices. 25VA of these 55VA can be used for constant load (e.g. a card reader) leaving 30VA for occasional peak usage (e.g. a door opener). 2020-01 | V02 | Installation manual Bosch Access Systems B.V.
  • Page 21: Rs-485 For Extension Modules

    The AMC2-4R4 is connected to the AMC2 controller using the RS-485 extension interface. This interface will also be used to connect further extension modules. Figure 4.9: Location of the RS-485 extension module bus Figure 4.10: Connection of an extension module to an AMC2 Bosch Access Systems B.V. Installation manual 2020-01 | V02 |...
  • Page 22: Wiegand Interface For Card Readers

    To operate locks or alarm systems, the AMC2-4W has eight relay outputs. The outputs will be connected to the 3-pin pluggable screw connectors S5, S6, S10, S11, S17, S18, S22, and S23 - refer to chapter Connecting Diagrams, page 33. 2020-01 | V02 | Installation manual Bosch Access Systems B.V.
  • Page 23 Wiegand relay types: – Flare move 12DC1W10A – Flare move 24DC1W16A If using locally manufactured products, please ensure that the specifications of the product are identical with the those listed above. Bosch Access Systems B.V. Installation manual 2020-01 | V02 |...
  • Page 24 Notice! Risk of damage to equipment Do not connect externally powered devices in wet mode. This can damage the AMC2-4W . 2020-01 | V02 | Installation manual Bosch Access Systems B.V.
  • Page 25 (D1) or wet ( D2) mode. Figure 4.15: Location of relay output jumpers (bottom side) Notice! The positions of the jumpers 1 and 2 are interchanged related to the corresponding interfaces. Bosch Access Systems B.V. Installation manual 2020-01 | V02 |...
  • Page 26: Connecting Analog Input Devices

    The following table shows the maximum values of permissible cable resistance depending on the used resistor combination. 1100 1100 1050 1050 1050 1100 1200 1200 1300 1300 1250 1300 1400 1500 1500 1500 1500 2020-01 | V02 | Installation manual Bosch Access Systems B.V.
  • Page 27 Access Modular Controller 2 Installing | en 1500 1650 1700 1800 1900 Table 4.2: Maximum values of cable resistance per used resistor combination in Ohm Bosch Access Systems B.V. Installation manual 2020-01 | V02 |...
  • Page 28: Tamper Protection

    | Installing Access Modular Controller 2 4.12 Tamper Protection Figure 4.17: Location of the tamper protection contact 2020-01 | V02 | Installation manual Bosch Access Systems B.V.
  • Page 29: Operating

    Operating Status Display of the AMC2 Because the AMC2-4R4 has no display of its own, the AMC2 controller displays status information about the input and output settings of the AMC2. Bosch Access Systems B.V. Installation manual 2020-01 | V02 |...
  • Page 30 + = online - = offline "C" = Counter of the received data packages from the host interface. RS 485 Bus connection: A = Address 1 … H = Address 8 2020-01 | V02 | Installation manual Bosch Access Systems B.V.
  • Page 31: Technical Data

    13° C to 35° C (55° F to 95° F) Humidity Up to 95%, without condensation Housing material ABS with OC (UL 94 V-0) Dimensions (W/H/D) 232 x 90 x 63mm (8.9 x 3.5 x 2.5 in) Weight approx. 0.53kg (1.2lb) Bosch Access Systems B.V. Installation manual 2020-01 | V02 |...
  • Page 32 | Technical Data Access Modular Controller 2 2020-01 | V02 | Installation manual Bosch Access Systems B.V.
  • Page 33: Appendices

    Access Modular Controller 2 Appendices | en Appendices Connecting Diagrams Figure 7.1: Connector blocks of the AMC2-4WE Bosch Access Systems B.V. Installation manual 2020-01 | V02 |...
  • Page 34 For reader settings refer to the respective reader manual. Analog Input, in Analog Input, out Tab. 7.5: Analog input Relay Output, normally open Relay Output, common Relay Output, normally closed Tab. 7.6: Relay output 2020-01 | V02 | Installation manual Bosch Access Systems B.V.
  • Page 35 Power supply for external devices (10V - 30V) Power supply for external devices (0V) Shield Data RxTx+ Data RxTx- Ground (PAG) Tab. 7.7: Host / Extension interface Tamper Contact, in Tamper Contact, out Tab. 7.8: External tamper contact Bosch Access Systems B.V. Installation manual 2020-01 | V02 |...
  • Page 36: Index

     9, 10 interfaces extension  31 reader  10, 22, 31 mounting  12 opening  14 outputs  9, 10, 22, 31 power supply  15, 18 reader interfaces  10, 22, 31 Wiegand  22 unmounting  13 2020-01 | V02 | Installation manual Bosch Access Systems B.V.
  • Page 37 Access Modular Controller 2 Index | Bosch Access Systems B.V. Installation manual 2020-01 | V02 |...
  • Page 38 | Index Access Modular Controller 2 2020-01 | V02 | Installation manual Bosch Access Systems B.V.
  • Page 40 Bosch Security Systems B.V. Torenallee 49 5617 BA Eindhoven Netherlands www.boschsecurity.com © Bosch Security Systems B.V., 2020...

This manual is also suitable for:

Ads-amc2-4we

Table of Contents