COMFORT-AIRE Century VMH-SV Series Service Manual page 80

Single-multi zone mini-split
Table of Contents

Advertisement

Procedure
6) Disconnect the wires connected to
the compressor. (Red wire connects
with PCB board, others connects with
terminals) (see CJ_ODU_PCB_002-3)
(For some models)
7) Disconnect the connectors for fan
motor. (Blue wire, red wire, brown
wire and black wire. The blue wire
and brown wire are on the capacitor.
The black wire connects with a
terminal. And the red wire is on the
borad.) (see CJ_ODU_PCB_002-3)(For
some models)
8) Disconnect the wires connected to
4-way valve. (see CJ_ODU_PCB_002-
3)(For some models)
9) Disconnect the wires connected
to the transformer. (see CJ_ODU_
PCB_002-3)(For some models)
10) Disconnect the other wires connected
to terminals. (see CJ_ODU_PCB_002-
3)(For some models)
11) Remove the PCB board. (see CJ_
ODU_PCB_002-3)(For some models)
Note: This section is for reference only. Actual unit appearance may vary.
3. PCB board 3
Procedure
1) Disconnect the connectors for fan
motor (see CJ_ODU_PCB_003).
2) Disconnect the wires connected
to the compressor (see CJ_ODU_
PCB_003).
3) Disconnect the wires connected to
Pipe temperature sensor (see CJ_
ODU_PCB_003).
4) Disconnect the earth wire (see CJ_
ODU_PCB_003).
5) Remove the PCB board (see CJ_ODU_
PCB_003).
Note: This section is for reference only. Actual unit appearance may vary.
Illustration
Compressor
Transformer
Illustration
Fan motor
Outdoor Unit Disassembly 52
Outdoor Unit Disassembly 22
Fan Motor
4-Way Valve
CJ_ODU_PCB_002-3
Earth wire
Pipe temperature sensor
Compressor
CJ_ODU_PCB_003

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents