Cooling chart(R32):
ODU(DB)
°F(°C)
IDU(DB/WB)
70/59 (21.11/15)
75/63 (23.89/17.22)
BAR
80/67 (26.67/19.44)
90/73 (32.22/22.78)
70/59 (21.11/15)
75/63 (23.89/17.22)
PSI
80/67 (26.67/19.44)
90/73 (32.22/22.78)
70/59 (21.11/15)
75/63 (23.89/17.22)
MPa
80/67 (26.67/19.44)
90/73 (32.22/22.78)
1.4
1.2
1
0.8
0.6
0.4
0.2
0
15
0(-17)
5(-15)
(-9.44)
6.5
6.6
7.4
6.8
6.9
8.1
7.2
7.3
8.7
7.9
8.0
9.8
95
96
108
99
101
117
105
106
125
114
115
142
0.65
0.66
0.74
0.68
0.69
0.81
0.72
0.73
0.87
0.79
0.80
0.98
Appendix 8
Appendix 8
45
75
85
(7.22)
(23.89)
(29.44)
8.2
8.4
8.0
8.8
8.8
8.5
9.7
9.5
9.1
10.7
10.5
9.7
118
121
115
128
126
122
141
138
132
155
152
141
0.82
0.84
0.80
0.88
0.88
0.85
0.97
0.95
0.91
1.07
1.05
0.97
105
115
95 (35)
(40.56)
(46.11)
8.3
8.8
10.3
8.9
9.3
10.9
9.3
9.8
11.4
10.2
10.8
12.6
119
128
150
129
135
158
135
143
165
148
157
184
0.83
0.88
1.03
0.89
0.93
1.09
0.93
0.98
1.14
1.02
1.08
1.26
70/59
75/63
80/67
90/73
120
(48.89)
10.8
11.4
12.1
13.3
157
165
176
193
1.08
1.14
1.21
1.33