A.4.
Mechanical Shock Specifications
Mechanical Bump/Shock
Axes
X, Y, Z
Directions
Positive and negative
Pulse interval
3 seconds
Pulse
shape
Operating
Half sine
Storage (X,Z)
Half sine
Storage (Y)
Half sine
Table A - 5
A.5.
Drop
Drop test
Standard
Drop sequence
Drop height
68
Pulse
duration
5ms
8ms
8ms
FastStor 1 mechanical shock levels
ASTM D-4169
10 drops, 1 corner, 3 edges, 6 faces
30 inches
Table A - 6
FastStor 1 drop test
Pulse
Pulses/axis/direction
Level
3g
1000
20g
3
15g
3
FastStor 1 Installation and User Guide