5 Start Up

5
Start Up
Drive Setup Procedure
The illustration below shows the basic setup procedure. Each step is explained more detailed
on the following pages.
* b1-01, b1-02 for frequency reference and RUN command source
* H1-
* Frequency reference values
* C1-
* E1-
18
Intstall and wire the drive as explained.
Initialize the drive if necessary using parameter A1-01.
Set/check the basic parameters:
, H2-
, H3-
, C2-
for Acceleration/Deceleration times and S-curves
, E2-
V/f pattern and motor data
Run the motor without load, check the operation and verify, if the
upper controller (e.g. PLC,...) commands to the drive work as
Connect the load, run the motor and check the operation
Fine tune and set application parameters if necessary.
Final check the operation and verify the settings.
Drive is ready to run the application
START
Turn the power on.
, H4-
, to configure the I/Os
desired.