Connections - ABB Tina 3A/Aps Original Instructions Manual

Table of Contents

Advertisement

3

Connections

Brown
Tina 3Aps
only
Blue
Green (x2)
Orange (x2)
Connection cables:
Brown:
+24 VDC (Tina 3Aps only)
Blue:
0 VDC (Tina 3Aps only)
Green:
Safety loop A1-A2
Orange:
Safety loop B1-B2
2
1
5
3
4
M12 5-pole male
seen from cable
side
NB: The connection cable cross section area is 0.34 mm
Caution! All cable colours according to ABB/Jokab Safety standard cables.
Caution! The safety loop cables (green and orange) should not be extended. The cables should be as short as
possible as longer cables increase the risk for electrical interference.
Warning!
The information channel output shall never be used for the safety purpose(s).
The connection cables are not monitored and must therefore be installed within the same physical enclosure as the
safety device to maintain the highest safety level (fault exclusion, refer to EN ISO 13849-2:2003 Annex D).
The safety loops shall not be used for purposes other than intended. All loading or tampering with loops can lead
to serious risk of life.
2TLC172125M0201, rev. A
2011-09-20
1
2
5
4
3
M12 5-pole female
seen from cable
side
2
5-pole M12 connector:
1 ) Brown:
2 ) White:
3 ) Blue:
4 ) Black:
5 ) Grey:
and cable length is 150 mm.
6
+24 VDC
Dynamic signal input
0 VDC
Dynamic signal output
Information