Technical Data - ABB Tina 3A/Aps Original Instructions Manual

Table of Contents

Advertisement

6

Technical data

Manufacturer
Address
Article number/Ordering data
Power supply
Operating voltage
Total current consumption
Time delay t (in/out)
Current through safety device contacts
Short circuit current between contacts
Voltage supply at normal operation (protection OK)
and 24 VDC supply voltage
General
Protection class
Ambient temperature
Humidity range
Housing material
Connectors
Size
Weight
Colour
Safety / Harmonized Standards
Conformity
IEC/EN 61508-1...7
EN 62061
EN ISO 13849-1
EN 954-1
Certificates
2TLC172125M0201, rev. A
2011-09-20
ABB AB / JOKAB SAFETY
Varlabergsvägen 11
SE-434 39 Kungsbacka
Sweden
Tina 3A: 2TLA020054R0200
Tina 3Aps: 2TLA020054R1400
24 VDC +15 %, -25 %
17 mA (27 mA with max information output)
Information output: Max 10 mA
t < 70 µs
12 mA
10 mA
Dynamic input: between 9 and 13 volt (RMS)
Dynamic output: between 9 and 13 volt (RMS)
Information output: ~ 23 VDC
IP67
Storage: -30...+70°C
Operation: -10...+55°C
35 to 85 % (with no icing or condensation)
PVC
M12 5-pole connector
Green loop wires (A1 & A2)
Orange loop wires (B1 & B2)
Brown (+24 VDC), Blue (0 VDC) wires (Tina 3Aps only)
56 x 27 x 24 (L x W x H)
~ 30 g
Black
European Machinery Directive 2006/42/EC
EN ISO 12100-1:2003, EN ISO 12100-2:2003,
EN 60204-1:2007, EN 954-1:1996, EN ISO 13849-1:2008,
EN 62061:2005
-9
SIL3, PFH
: 4.50*10
d
SIL3
Performance level: Pl e, category 4
Category 4
TÜV Nord
11
www.abb.com/lowvoltage

Advertisement