Before Installation

Components

Preparation

Door Preparation

  • 54mm hole saw
  • 25mm hole saw
  • Chisel and hammer

Fixing

  • Screwdriver
  • Drill

Factory Reset

  • Press and hold the "SET" button, and in five seconds you will hear "Du...Du...Du...DuDu", release the button, voice prompt "successfully", represents reset Ok, then release the "SET" button.

    Factory default administrator PIN Code is 123456
    Note: After initializing, any CARD or factory default PIN code 123456 can unlock.

Start Up

Register administrators

  • Press "SET" button or press "*" then "#" keys to activate the setting mode.
    Voice broadcast: "Add administrator", Please enter card or PIN code to add.
    Start Up - Registering the administrators
  • Enter a new PIN code (6 to 12 digits) and then press " # "or swipe the RF card.
    (successfully" will be heard after successful registration.)

Note: The lock will exit the setting mode after 12 seconds if no operation or press " * " key to exit the setting mode.
Factory default PIN code 123456 will be invalidated after Administrator registration completed.

Register Users

  • Touch lights up the keyboard, press " * " and then "# ";
    Or short press the " SET " button, voice broadcast:
    "Please verify admin" and then enter the administrator information
    Start Up - Registering the Users
  • Voice broadcast after verification
    "1 Add User 2 Delete User 3 Lock Settings 4 Add Admin"
    Press 1 to enter the Add User according to Voice guide.
    Enter a PIN code or card to enter user information

Note:

  1. The lock will exit the setting mode after 12 seconds if no operation or press " * " key to exit the setting mode.
  2. Repeated registered -PIN code is not allowed.

Add administrator

  • Touch lights up the keyboard, press " * " and then " # ";
    Or short press the set button, voice broadcast:
    "Please verify admin" and then enter registered administrator PIN code.
    Adding an administrator - Step 1
  • Voice broadcast after verification
    "1 Add User 2 Delete User 3 Lock Settings 4 Add Admin"
    Press 4 to enter the Add Admin state and voice broadcast:"add admin"
    Enter a PIN code or card to enter administration information.
    Adding an administrator - Step 2

Note: Maximum 9 administrators can be saved.
The administrator has the authorization to enter to Setting mode and open door.

Modification

Delete user information

  • Touch lights up the keyboard, press " * " and then " # ";
    Or short press the " SET " button, voice broadcast:
    "Please verify admin" and then enter the administrator information
    Delete user information - Step 1
  • Voice guide after verification
    "1 Add User 2 Delete User 3 Lock Settings 4 Add Admin"
    Press 2 to enter the Delete User state and voice broadcast:"Delete user"
    Swipe the key card or enter the user number or PIN code on the keyboard sensor area, press "#" to confirm the input, and then press "#" to confirm the deletion.
    Delete user information - Step 2

Note: The lock will exit the setting mode after 12 seconds if no operation or press " * " key to exit the setting mode.

Delete all user information

  • According to operation 3.1, enter the delete user state and enter 000#.
    Voice broadcast "DuDu" and then press " # " to confirm deleting all users.
    Deleting all user information

Note:

  1. The lock will exit the setting mode after 12 seconds if no operation or press " * " key to exit the setting mode.
  2. After all deletion, only users are deleted, not administrators.

Usage

Open Door by PIN Code

  • Touch the keypad. Enter 6~16 digits (PIN code and fake PIN code) and press " # " to confirm. The confirmation sound will be heard if the PIN code is correct. Then turn lever to open the door within 8 seconds. After that, The confirmation sound will be heard again and door will be locked.
    (Fake PIN code can input before and after the PIN code.)
    Usage - Opening a Door by PIN Code
  • The RED light will ON and a voice prompt will be heard if PIN code is NOT matched.
    (RED light will be ON and the system will lock for 1 minute after 5 consecutive failed try by key card/PIN code.)

Open Door by KeyCard

  • Touch the keypad. Swipe the KeyCard on keypad induction zone. Then turn lever to open the door within 8 seconds.

The RED light will ON and a voice prompt will be heard if the key card is NOT matched.
(RED light will be ON and the system will lock for 1 minute after 5 consecutive failed try by key card/PIN code.)

Entry door lock setting

Voice broadcast after verification
"1 Add User 2 Delete User 3 Lock Settings 4 Add Admin"
Press 3 to enter the Lock Setting state.
Entry door lock setting
Voice broadcast:
"1 Function Settings 2 Volume Setting 3 Language Settings"
Settings tray overview

Function Setting

  • Function setting include:
  1. Enable Passage
  2. Enable Dual Verify
  3. Enable Keypad Mute

Enable Passage (Keep unlocked)

  • Follow the 5 operation, after entering the lock setting, press 1 according to voice guide:
    "1 Enable Passage 2 Enable Dual Verify 3 Enable Mute"
    Select 1 to turn on the passage mode and voice broadcast:
    "1 Disable Passage 2 Enable Dual Verify 3 Enable Mute"
    To turn off the passage mode, select this option to turn it off.

Note: After the passage open mode is turned on, the door will keep unlocked state, and the door will NOT be automatically locked. Press the " # " key to lock.

Dual Verify

  • Follow the 5 operation, after entering the lock setting, press 1 to enter the function setting according to Voice guide:
    "1 Enable Passage 2 Enable Dual Verify 3 Enable Mute"
    Select 2 to turn on the Dual Verify mode and voice broadcast:
    "1 Enable Passage 2 Disable Dual Verify 3 Enable Mute"
    To turn off the Dual Verify mode, select this option to turn it off.

Note: In Dual Verify mode, the door can only be opened after verifying the success of two users.

Mute keypad mode

  • Follow the 5 operation, after entering the lock setting, press 1 to enter the function setting Voice broadcast:
    "1 Enable Passage 2 Enable Dual Verify 3 Enable Mute"
    Select 3 to turn on the Mute mode and voice broadcast:
    "1 Enable Passage 2 Enable Dual Verify 3 Disable Mute"
    To turn off the Mute mode, select this option to turn it off.

Note: After the mute mode is turned on, the key tone will be cancelled, and every unlocked will be muted.

Voice Volume Setting

  • Follow the 5 operation, after entering the lock setting, press 2 to enter the Volume setting. according to Voice guide:
    "1 volume up 2 volume down", press 1 volume to increase, press 2 to decrease volume.

Language Setting

  • Follow the 5 operation, after entering the lock setting, press 3 to enter the Language setting. according to Voice guide:
    "1 Chinese 2 English", press 1 to select Chinese voice prompt, press 2 to select English voice prompt.

Built In Function

Low battery alarm

  • When the low battery indicator is on (flashing red), the voice prompts "low power", indicating that the battery will run out soon.
    Built In Function - Indication
  • Please replace the battery.

Unlock Indicator

  • The unlock indicator light on (green) when allow to open door by lever.

KeyCard Induction Zone

  • Best position for detecting KeyCard.

Power shortage

  • In the case of insufficient battery, the lock can be powered by USB port at the bottom of the outside panel.
    Power shortage - Powering the lock by USB port

No response

  • Press "Quick Restart" button if the lock is unresponsive.

Note: PIN Code & KeyCard remained unchange.

Key Operation

  • Press end of the lever to open cover for unlock the door by key (even batteries run out).
    Key Operation

Specifications

  • KeyCard Memory:
    Password + key cards ≤ 300
    (Administrator ID: 001~009, User ID: 10~300)
  • PIN Code:
    6 ~ 10 numerical digits
  • Card Readable Distance:
    10mm below
  • Battery:
    4 x AAA alkaline batteries
  • Low Battery Alarm Effect
    4.8V below
  • Static Consumption:
    40uA below
  • Dynamic Consumption:
    300mA below
  • Operation Temperature:
    -25C ~ +50C
  • Storage Temperature:
    -40C ~ +55C
  • Relative Humidity:
    10% ~ 90%
  • Automatically locking
    8s

Documents / Resources

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Download Yale EC800 - Smart Lock Manual

Advertisement

Need Assistance?

Do you have a question about the EC800 that isn't answered in the manual? Leave your question here.

Error while submitting your question. Please, reload page and try again.

Thank you! Your question has been received!

Table of Contents