Before Installation
Components
![]()
Preparation
Door Preparation
- 54mm hole saw
- 25mm hole saw
- Chisel and hammer
Fixing
Factory Reset
- Press and hold the "SET" button, and in five seconds you will hear "Du...Du...Du...DuDu", release the button, voice prompt "successfully", represents reset Ok, then release the "SET" button.
![]()
Factory default administrator PIN Code is 123456
Note: After initializing, any CARD or factory default PIN code 123456 can unlock.
Start Up
Register administrators
- Press "SET" button or press "*" then "#" keys to activate the setting mode.
Voice broadcast: "Add administrator", Please enter card or PIN code to add.
![Yale - EC800 - Start Up - Registering the administrators Start Up - Registering the administrators]()
- Enter a new PIN code (6 to 12 digits) and then press " # "or swipe the RF card.
(successfully" will be heard after successful registration.)
![]()
Note: The lock will exit the setting mode after 12 seconds if no operation or press " * " key to exit the setting mode.
Factory default PIN code 123456 will be invalidated after Administrator registration completed.
Register Users
- Touch lights up the keyboard, press " * " and then "# ";
Or short press the " SET " button, voice broadcast:
"Please verify admin" and then enter the administrator information
![Yale - EC800 - Start Up - Registering the Users Start Up - Registering the Users]()
- Voice broadcast after verification
"1 Add User 2 Delete User 3 Lock Settings 4 Add Admin"
Press 1 to enter the Add User according to Voice guide.
Enter a PIN code or card to enter user information
Note:
- The lock will exit the setting mode after 12 seconds if no operation or press " * " key to exit the setting mode.
- Repeated registered -PIN code is not allowed.
Add administrator
- Touch lights up the keyboard, press " * " and then " # ";
Or short press the set button, voice broadcast:
"Please verify admin" and then enter registered administrator PIN code.
![Yale - EC800 - Adding an administrator - Step 1 Adding an administrator - Step 1]()
- Voice broadcast after verification
"1 Add User 2 Delete User 3 Lock Settings 4 Add Admin"
Press 4 to enter the Add Admin state and voice broadcast:"add admin"
Enter a PIN code or card to enter administration information.
![Yale - EC800 - Adding an administrator - Step 2 Adding an administrator - Step 2]()
Note: Maximum 9 administrators can be saved.
The administrator has the authorization to enter to Setting mode and open door.
Modification
- Touch lights up the keyboard, press " * " and then " # ";
Or short press the " SET " button, voice broadcast:
"Please verify admin" and then enter the administrator information
![Yale - EC800 - Delete user information - Step 1 Delete user information - Step 1]()
- Voice guide after verification
"1 Add User 2 Delete User 3 Lock Settings 4 Add Admin"
Press 2 to enter the Delete User state and voice broadcast:"Delete user"
Swipe the key card or enter the user number or PIN code on the keyboard sensor area, press "#" to confirm the input, and then press "#" to confirm the deletion.
![Yale - EC800 - Delete user information - Step 2 Delete user information - Step 2]()
Note: The lock will exit the setting mode after 12 seconds if no operation or press " * " key to exit the setting mode.
- According to operation 3.1, enter the delete user state and enter 000#.
Voice broadcast "DuDu" and then press " # " to confirm deleting all users.
![Yale - EC800 - Deleting all user information Deleting all user information]()
Note:
- The lock will exit the setting mode after 12 seconds if no operation or press " * " key to exit the setting mode.
- After all deletion, only users are deleted, not administrators.
Usage
Open Door by PIN Code
- Touch the keypad. Enter 6~16 digits (PIN code and fake PIN code) and press " # " to confirm. The confirmation sound will be heard if the PIN code is correct. Then turn lever to open the door within 8 seconds. After that, The confirmation sound will be heard again and door will be locked.
(Fake PIN code can input before and after the PIN code.)
![Yale - EC800 - Usage - Opening a Door by PIN Code Usage - Opening a Door by PIN Code]()
- The RED light will ON and a voice prompt will be heard if PIN code is NOT matched.
(RED light will be ON and the system will lock for 1 minute after 5 consecutive failed try by key card/PIN code.)
Open Door by KeyCard
- Touch the keypad. Swipe the KeyCard on keypad induction zone. Then turn lever to open the door within 8 seconds.
![]()
The RED light will ON and a voice prompt will be heard if the key card is NOT matched.
(RED light will be ON and the system will lock for 1 minute after 5 consecutive failed try by key card/PIN code.)
Entry door lock setting
Voice broadcast after verification
"1 Add User 2 Delete User 3 Lock Settings 4 Add Admin"
Press 3 to enter the Lock Setting state.
![Yale - EC800 - Entry door lock setting Entry door lock setting]()
Voice broadcast:
"1 Function Settings 2 Volume Setting 3 Language Settings"
![Yale - EC800 - Settings tray overview Settings tray overview]()
Function Setting
- Function setting include:
- Enable Passage
- Enable Dual Verify
- Enable Keypad Mute
Enable Passage (Keep unlocked)
- Follow the 5 operation, after entering the lock setting, press 1 according to voice guide:
"1 Enable Passage 2 Enable Dual Verify 3 Enable Mute"
Select 1 to turn on the passage mode and voice broadcast:
"1 Disable Passage 2 Enable Dual Verify 3 Enable Mute"
To turn off the passage mode, select this option to turn it off.
![]()
Note: After the passage open mode is turned on, the door will keep unlocked state, and the door will NOT be automatically locked. Press the " # " key to lock.
Dual Verify
- Follow the 5 operation, after entering the lock setting, press 1 to enter the function setting according to Voice guide:
"1 Enable Passage 2 Enable Dual Verify 3 Enable Mute"
Select 2 to turn on the Dual Verify mode and voice broadcast:
"1 Enable Passage 2 Disable Dual Verify 3 Enable Mute"
To turn off the Dual Verify mode, select this option to turn it off.
![]()
Note: In Dual Verify mode, the door can only be opened after verifying the success of two users.
Mute keypad mode
- Follow the 5 operation, after entering the lock setting, press 1 to enter the function setting Voice broadcast:
"1 Enable Passage 2 Enable Dual Verify 3 Enable Mute"
Select 3 to turn on the Mute mode and voice broadcast:
"1 Enable Passage 2 Enable Dual Verify 3 Disable Mute"
To turn off the Mute mode, select this option to turn it off.
![]()
Note: After the mute mode is turned on, the key tone will be cancelled, and every unlocked will be muted.
Voice Volume Setting
- Follow the 5 operation, after entering the lock setting, press 2 to enter the Volume setting. according to Voice guide:
"1 volume up 2 volume down", press 1 volume to increase, press 2 to decrease volume.
Language Setting
- Follow the 5 operation, after entering the lock setting, press 3 to enter the Language setting. according to Voice guide:
"1 Chinese 2 English", press 1 to select Chinese voice prompt, press 2 to select English voice prompt.
Built In Function
Low battery alarm
- When the low battery indicator is on (flashing red), the voice prompts "low power", indicating that the battery will run out soon.
![Yale - EC800 - Built In Function - Indication Built In Function - Indication]()
- Please replace the battery.
Unlock Indicator
- The unlock indicator light on (green) when allow to open door by lever.
KeyCard Induction Zone
- Best position for detecting KeyCard.
Power shortage
- In the case of insufficient battery, the lock can be powered by USB port at the bottom of the outside panel.
![Yale - EC800 - Power shortage - Powering the lock by USB port Power shortage - Powering the lock by USB port]()
No response
- Press "Quick Restart" button if the lock is unresponsive.
Note: PIN Code & KeyCard remained unchange.
Key Operation
- Press end of the lever to open cover for unlock the door by key (even batteries run out).
![Yale - EC800 - Key Operation Key Operation]()
Specifications
- KeyCard Memory:
Password + key cards ≤ 300
(Administrator ID: 001~009, User ID: 10~300) - PIN Code:
6 ~ 10 numerical digits - Card Readable Distance:
10mm below - Battery:
4 x AAA alkaline batteries - Low Battery Alarm Effect
4.8V below - Static Consumption:
40uA below - Dynamic Consumption:
300mA below - Operation Temperature:
-25C ~ +50C - Storage Temperature:
-40C ~ +55C - Relative Humidity:
10% ~ 90% - Automatically locking
8s