NOTE The Declaration of Conformity for these devices can be requested from the manufacturer. The manufacturer of the product, Leuze electronic GmbH + Co. KG in D-73277 Owen, possesses a certi- fied quality assurance system in accordance with ISO 9001.
The device must not be tampered with and must not be changed in any way. The device must not be opened. There are no user-serviceable parts inside. Repairs must only be performed by Leuze electronic GmbH + Co. KG. Competent persons Connection, mounting, commissioning and adjustment of the device must only be carried out by competent persons.
Exemption of liability Leuze electronic GmbH + Co. KG is not liable in the following cases: • The device is not being used properly. • Reasonably foreseeable misuse is not taken into account. • Mounting and electrical connection are not properly performed.
Page 9
AVOID EXPOSURE – LASER RADIATION IS EMITTED FROM THIS APERTURE Laser aperture Laser warning sign Laser information sign with laser parameters Figure 2.2: Laser aperture, laser warning and information signs - oscillating-mirror scanner Leuze electronic GmbH + Co. KG BCL 608...
Page 10
<150 µs <150 µs Wavelength: 405 nm 405 nm CLASS 2 LASER PRODUCT IEC 60825-1:2014 Complies with 21 CFR 1040.10 IEC 60825-1:2014 Figure 2.3: Laser warning and information signs – supplied stick-on labels Leuze electronic GmbH + Co. KG BCL 608...
• Numerous interface variants facilitate connection to the superior systems • RS 232, RS 422 as well as with integrated multiNet plus master • RS 485 and multiNet plus slave Alternatively, various fieldbus systems, such as PROFINET-IO Ethernet TCP/IP Ethernet/IP Profibus Leuze electronic GmbH + Co. KG BCL 608...
Page 12
• Automatic recognition and setting of the bar code type using autoConfig • Reference code comparison • Optional heating models to -35 °C • Heavy-duty housing of degree of protection IP 65 Leuze electronic GmbH + Co. KG BCL 608...
Device construction Reading window Control panel with display, LEDs and buttons M12 connection technology USB interface Dovetail mounting M4 mounting thread Figure 3.2: Device construction Leuze electronic GmbH + Co. KG BCL 608...
Figure 3.3: Location of the electrical connections Display elements 3.5.1 Structure of the control panel PWR LED NET LED Navigation buttons Escape button Enter button Display Figure 3.4: Structure of the control panel Leuze electronic GmbH + Co. KG BCL 608...
• No data on the host interface Flashes red Device ok, warning set • Bar code reading possible • Temporary operating fault Red, continuous Device error / parameter enable light • No bar code reading possible Leuze electronic GmbH + Co. KG BCL 608...
To mount, the cover of the service interface must be unscrewed. Then screw the tube body onto the USB connection on the device and plug the USB memory stick into the connection and close the connector hood with the cover to ensure degree of protection IP 65. Leuze electronic GmbH + Co. KG BCL 608...
The four freely configurable switching inputs/outputs SWIO 1 … SWIO 4 can be assigned various func- tions and control e.g. activation of the device or external devices, such as a PLC. System, warning and error messages provide assistance in setup/troubleshooting during commissioning and read operation. Leuze electronic GmbH + Co. KG BCL 608...
For low-temperature applications to min. -35°C (e.g. in cold storage), the bar code readers of the BCL 600 series can optionally be permanently fitted with a built-in heating and these bar code readers purchased as separate device models. Leuze electronic GmbH + Co. KG BCL 608...
In this way, the device can also scan larger areas or spaces for bar codes. The reading field height (and the scan line length useful for evaluation) depends on the reading distance due to the optical opening angle of the oscillating mirror. Leuze electronic GmbH + Co. KG BCL 608...
Page 21
• When the bar code is turned out of the horizontal position. • When the reading distance is large. • When a large reading field (reading window) has to be covered. Figure 5.2: Deflection principle for the line scanner with oscillating mirror add-on Leuze electronic GmbH + Co. KG BCL 608...
Thus, from the perspective of the host, the scanner network appears to be just a single bar code reader! For this purpose one multiScan master and one or more multiScan slaves are connected together via Ethernet/PROFINET. Leuze electronic GmbH + Co. KG BCL 608...
Page 23
Figure 5.4: Scanner arrangement with the multiScan function NOTE The multiScan function for Ethernet/PROFINET is possible for a minimum of 2 and a maximum of 32 devices! Leuze electronic GmbH + Co. KG BCL 608...
Total reflection occurs whenever the laser light of the bar code reader is directly incident on the surface of the bar code at an angle of 90°. The light directly reflected by the bar code may overload the bar code reader and thereby cause non-readings! Leuze electronic GmbH + Co. KG BCL 608...
The optimum alignment of the device is accomplished when the scan line scans the bar code bars almost at a right angle (90°). All reading angles that are possible between the scan line and bar code must be taken account (see figure 6.3). Leuze electronic GmbH + Co. KG BCL 608...
Mount the external parameter memory on the new device. Install and start up the new device. The following message appears on the display again: • Memory stick connected: Export internal configuration? Leuze electronic GmbH + Co. KG BCL 608...
Page 27
Make sure you select Cancel. Otherwise, the configuration in the external parameter memory is lost! The configuration is now imported from the external parameter memory and the device is immediately operational without any further configuration. Leuze electronic GmbH + Co. KG BCL 608...
PWR, M12 connector (A-coded) Figure 7.1: Connections of the device Voltage supply and switching inputs/outputs The voltage supply (10 … 30 V DC) is connected at the PWR / SWIO M12 plug. Leuze electronic GmbH + Co. KG BCL 608...
The two switching inputs/outputs SWIO_1 and SWIO_2 are located on the SW IN/OUT M12 socket (see chapter 7.4). The other two (SWIO_3 and SWIO_4) of the four freely configurable switching inputs/outputs are located on the PWR M12 connector. Leuze electronic GmbH + Co. KG BCL 608...
Page 30
60 mA at +10 … +30 V DC in normal operation! NOTE By default, the two switching inputs/outputs SWIO_3 and SWIO_4 are configured so that switch- ing input SWIO_3 activates the reading gate and switching output SWIO_4 switches on "No Read". Leuze electronic GmbH + Co. KG BCL 608...
IP 65 is achieved only if the connectors and caps are screwed into place. Alternatively, a param- eter memory in the form of a USB memory stick certified by Leuze electronic GmbH + Co. can be connected to the provided USB service interface. With this Leuze memory stick, degree of protection IP 65 is also ensured.
If, for example, the inverted sensor output is connected to pin 2, and pin 2 of the bar code reader is, at the same time, configured as an output (and not as an input), the switching output malfunctions. Leuze electronic GmbH + Co. KG BCL 608...
Figure 7.9: Host/BUS IN, M12 socket (D-coded) Table 7.4: Pin assignment HOST / BUS IN Name Comment Transmit Data + Receive Data + Transmit Data - Receive Data - Thread Functional earth (housing) Leuze electronic GmbH + Co. KG BCL 608...
Ethernet device (acc. to IEEE 802.3) with a standard baud rate of 10/ 100 Mbit. A fixed MAC ID is assigned to each device by the manufacturer; this address cannot be Leuze electronic GmbH + Co. KG BCL 608...
Page 35
Each participant in this network requires its own unique IP address which must be assigned via the display or webConfig tool; alternatively, the DHCP method can also be used. The maximum length of a segment (connection from the hub to the last participant) is limited to 100 m. Leuze electronic GmbH + Co. KG BCL 608...
100 m for 100Base-TX Twisted Pair (min. Cat. 5) BCL – power supply 30 m Not necessary unit Switching input 10 m Not necessary Switching output 10 m Not necessary Leuze electronic GmbH + Co. KG BCL 608...
By pressing the enter button after selecting Parameters to default, all parameters are reset to their stan- dard settings without any further security prompts. In this case, English is selected as the display language. Leuze electronic GmbH + Co. KG BCL 608...
Page 38
Check digit transm. Standard Standard Not standard Specifies whether the check digit is transmitted. Standard means that the transmission matches the standard intended for the respective code type. Leuze electronic GmbH + Co. KG BCL 608...
Page 39
0 to 64 characters Number of digits 0 to 64 characters Reading reliability Value from 2 to 100 Check digit method Same as decoder 1 Standard Check digit transm. Same as decoder 1 Standard Leuze electronic GmbH + Co. KG BCL 608...
Page 40
No BCL600 operation Reading gate Reading gate start/stop start/stop Reading gate stop -Reading gate start Teach reference code Autoconfig start/stop The function set here is carried out after the switching input is activated. Leuze electronic GmbH + Co. KG BCL 608...
Page 41
Value from 0 to 65535 Pulse duration Value from 0 to 65535 Activation function 2 See switching input/output 1 Valid read result Deactivation function 2 See switching input/output 1 Reading gate start Leuze electronic GmbH + Co. KG BCL 608...
Page 42
Value from 0 to 65535 Pulse duration Value from 0 to 65535 Activation function 4 See switching input/output 1 Invalid read result Deactivation function 4 See switching input/output 1 Reading gate start Leuze electronic GmbH + Co. KG BCL 608...
Page 43
(host system) does not respond. Repetition time The repetition time can be set to any value between 5000 ms 100 and 60,000 ms. Time after which another attempt is made to establish a connection. Leuze electronic GmbH + Co. KG BCL 608...
Service menu Diagnosis This menu item is used exclusively for service purposes by Leuze electronic. Status messages This menu item is used exclusively for service purposes by Leuze electronic. Actions menu Start decoding Here, you can perform a single reading via the display.
Page 45
The following display appears: RC13xxzzzzzz RC13 Means that ReferenceCode number 1 is stored in RAM. This is always output Defined code type (see auto setup) Defined code information (1 … 63 characters) Leuze electronic GmbH + Co. KG BCL 608...
Press the enter button to enter the menu. The PWR LED lights up red. You can now set individual parameters via the display. Press the Escape button twice to return to the main menu. Leuze electronic GmbH + Co. KG BCL 608...
Upon successful installation of the USB driver, an icon automatically appears on the desktop. To check: In the Windows device manager, a device called "Leuze electronic, USB Remote NDIS Network Device" appears under the "Network adapter" device class following successful USB registration.
PC via the USB interface and that voltage is connected. Or alternatively: Open a browser on your PC and enter the following address: 192.168.61.100. This is the default Leuze service address for communication with bar code readers of the BCL 600 series.
The individual modules and their relationships to one another are graphically displayed in the module over- view. The display is context sensitive, i.e. click a module to directly access the corresponding submenu. Leuze electronic GmbH + Co. KG BCL 608...
Page 50
Activation/deactivation of read processes • Switching output Definition of events which activate/deactivate the switching output • Display Formatting of the data for output on the display • Oscillating mirror (optional) Setting oscillating mirror parameters Leuze electronic GmbH + Co. KG BCL 608...
To use the webConfig tool, you need to establish a USB connec- tion between the device and a PC/laptop. NOTE Notes on use see chapter 9 "Commissioning – Leuze electronic webConfig tool". Via display The display offers basic configuration options for the device. Configuration via the display is appropriate if you want to configure simple reading tasks and you cannot or do not want to set up a USB connection between the device and a PC/laptop.
IP address in a ping command (e.g. ping 192.168.60.101 in a command line window under Windows). 10.3.3 Address Link Label Address Link Label is an additional stick-on label that is affixed to the device. Leuze electronic GmbH + Co. KG BCL 608...
The device requires from the user the IP address of the server (host system) and the port number on which the server (host system) accepts a connection. In this case, the device determines when and with whom a connection is established! Leuze electronic GmbH + Co. KG BCL 608...
Press the enter button to enter the menu. Select the Host communication menu item. Press the enter button to enter the menu. Select the UDP menu item. Press the enter button to enter the menu. Leuze electronic GmbH + Co. KG BCL 608...
Via a switching input, you can: • Start decoding • Stop decoding • Start decoding and then stop decoding after a configurable time period • Read a reference code • Start the automatic code type configuration (AutoConfig) Leuze electronic GmbH + Co. KG BCL 608...
In general, there are two possibilities for transferring configuration data between two bar code readers: • Storage in a file and transfer using the webConfig tool • Using the external parameter memory Leuze electronic GmbH + Co. KG BCL 608...
The device stores a copy of the current configuration in the external parameter memory. This copy is immediately updated when the configuration is changed via the display or by a superior host system (PC/PLC) via online commands. Leuze electronic GmbH + Co. KG BCL 608...
This command can be used to check whether the connected host or service computer is properly connected and configured. If you do not receive an acknowledgment, please check interface connections, protocol and service switches. Leuze electronic GmbH + Co. KG BCL 608...
Page 59
Parameter Activates autoConfig Rejects the last code read Deactivates autoConfig and stores the decoded data in the cur- rent parameter set Leuze electronic GmbH + Co. KG BCL 608...
Page 60
The duration of the pauses has been stepped in such a way that they can be distinguished by the eye. Parameter Starts the adjustment mode. Ends the adjustment mode. Leuze electronic GmbH + Co. KG BCL 608...
Page 61
Input = RS130678654331 (Code 1 (1), RAM only (3), UPC (06), code informa- tion) Reference code teach-in Command Description This command enables a reference code to be defined quickly by reading an example label. Leuze electronic GmbH + Co. KG BCL 608...
Page 62
The command reads out the reference code defined in the device. If no parameters are specified, all defined codes are output. Parameter <reference code number> 1 … 2 value range of reference code 1 to 2 Leuze electronic GmbH + Co. KG BCL 608...
Following deactivation, the read result is output. Because the reading gate was manually deactivated and, thus, no GoodRead criterion was met, a NoRead is output. Parameter Acknowledgment None Leuze electronic GmbH + Co. KG BCL 608...
Copying the default parameters to the permanent memory and to the main memory Acknowledgment PS=<aa> <aa> Status acknowledgment, unit [dimensionless] Syntax error Impermissible command length Reserved Reserved Reserved Impermissible combination, source type - target type Leuze electronic GmbH + Co. KG BCL 608...
Page 65
Relative address of the data within the data set aaaa Four-digit, unit [dimensionless] <Data length> Length of the parameter data to be transferred bbbb Four-digit, unit [length in bytes] <BCC> Check sum calculated as specified under BCC type Leuze electronic GmbH + Co. KG BCL 608...
Page 66
Invalid check sum received Impermissible number of data requested Requested data does not (any longer) fit in the transmission buffer Impermissible address value Read access after end of data set Impermissible QPF data set type Leuze electronic GmbH + Co. KG BCL 608...
Page 67
Output of the parameter differences between the default parame- ter set and the operating parameter set saved in volatile memory Output of the parameter differences between the permanent parameter set and the operating parameter set saved in volatile memory Leuze electronic GmbH + Co. KG BCL 608...
Page 68
(factory parameter set) for initialization. This command can be used to edit the first two parameter sets (in permanent and volatile memory). A check sum can be used for reliable parameter transfer. Leuze electronic GmbH + Co. KG BCL 608...
Page 69
Parameter value of the -bb- parameter stored at this address. The parameter set data is converted from HEX format to a 2-byte-ASCII format for transfer. <BCC> Check sum calculated as specified under BCC type. Leuze electronic GmbH + Co. KG BCL 608...
Page 70
[dimensionless] Syntax error Impermissible command length Impermissible value for checksum type Invalid check sum received Impermissible data length Invalid data (parameter limits violated) Invalid start address Invalid parameter set Invalid parameter type Leuze electronic GmbH + Co. KG BCL 608...
NOTE Do not use aggressive cleaning agents such as thinner or acetone for cleaning the device. 12.2 Servicing 12.3 Disposing For disposal observe the applicable national regulations regarding electronic components. Leuze electronic GmbH + Co. KG BCL 608...
• Avoid EMC coupling caused by power cables laid parallel to device lines • Overall network expansion exceeded • Check max. network expansion as a func- tion of the max. cable lengths Leuze electronic GmbH + Co. KG BCL 608...
Service and support Service hotline You can find the contact information for the hotline in your country on our website www.leuze.com under Contact & Support. Repair service and returns Defective devices are repaired in our service centers competently and quickly. We offer you an extensive service packet to keep any system downtimes to a minimum.
Number of bar codes per scan Table 15.3: Interface Interface type Interface type: 2x Ethernet on 2x M12 (D) Protocols Protocols: Ethernet TCP/IP (client / server) / UDP Baud rate 10/100 MBaud Leuze electronic GmbH + Co. KG BCL 608...
Page 75
-6) a) This is a Class A product. In a domestic environment this product may cause radio interference, in which case the oper- ator may be required to take adequate measures. Leuze electronic GmbH + Co. KG BCL 608...
The front cover heater remains activated until an inside temperature of 25 °C is reached. At temperatures above this, the front cover heater switches off and, with a switching hysteresis of 3 °C, back on again at an inside temperature below 22 °C. Leuze electronic GmbH + Co. KG BCL 608...
Standard, M12 preassembled cable is not usable (insufficient cable cross-section) Environmental data Operating tem- -35 °C … +40 °C perature range Storage temper- -20 °C … +70 °C ature range Leuze electronic GmbH + Co. KG BCL 608...
Standard, M12 preassembled cable not usable (insufficient cable cross-section). Environmental data Operating tem- -35 °C … +40 °C perature range Storage temper- -20 °C … +70 °C ature range Leuze electronic GmbH + Co. KG BCL 608...
15.3 Dimensioned drawings Optical axis M4, 7 mm deep M4, 6 mm deep Figure 15.1: Dimensioned drawing - line scanner Leuze electronic GmbH + Co. KG BCL 608...
Page 80
Optical axis Optical swivel range Opening angle M4, 7 mm deep M4, 6 mm deep Figure 15.2: Dimensioned drawing - oscillating-mirror scanner Leuze electronic GmbH + Co. KG BCL 608...
The zero position of the reading distance always refers to the front edge of the housing of the beam exit and is shown for the two housing types of the device (see figure 15.6). Leuze electronic GmbH + Co. KG BCL 608...
Page 83
Zero position of the reading distance Reading conditions for the reading field curves Table 15.13: Reading conditions Bar code type 2/5 Interleaved Ratio 1:2.5 ANSI specification Class A Reading rate > 75% Leuze electronic GmbH + Co. KG BCL 608...
Module = 0.3 mm: 400 mm - 800 mm (400 mm depth of field) Module = 0.35 mm: 400 mm - 900 mm (500 mm depth of field) Figure 15.8: Lateral Medium Density reading field curve for oscillating-mirror scanners Leuze electronic GmbH + Co. KG BCL 608...
Module = 0.35 mm: 500 mm - 1200 mm (700 mm depth of field) Module = 0.5 mm: 450 mm - 1450 mm (1000 mm depth of field) Figure 15.9: Reading field curve - Low Density for line scanner Leuze electronic GmbH + Co. KG BCL 608...
• The reading field curves and opening angles are unchanged for all line scanners with heating of the series BCL 600 For details, please refer to the following reading field curves for the heating devices. Leuze electronic GmbH + Co. KG BCL 608...
Module = 0.3 mm: 400 mm - 800 mm (400 mm depth of field) Module = 0.35 mm: 400 mm - 900 mm (500 mm depth of field) Figure 15.12: "Medium Density" reading field curve for oscillating-mirror scanners with heating Leuze electronic GmbH + Co. KG BCL 608...
Page 88
Module = 0.35 mm: 400 mm - 900 mm (500 mm depth of field) Figure 15.13: Lateral "Medium Density" reading field curve for oscillating-mirror scanners with heating The reading field curve applies for the reading conditions stated above (see table 15.13). Leuze electronic GmbH + Co. KG BCL 608...
Module = 0.5 mm: 450 mm - 1450 mm (1000 mm depth of field) Figure 15.14: "Low Density" reading field curve for line scanner with heating The reading field curve applies for the reading conditions stated above (see table 15.13). Leuze electronic GmbH + Co. KG BCL 608...
Module = 0.35 mm: 500 mm - 1200 mm (700 mm depth of field) Module = 0.5 mm: 450 mm - 1450 mm (1000 mm depth of field) Figure 15.15: "Low Density" reading field curve for oscillating-mirror scanners with heating Leuze electronic GmbH + Co. KG BCL 608...
Page 91
Module = 0.5 mm: 450 mm - 1450 mm (1000 mm depth of field) 2/5l Figure 15.16: Lateral "Low Density" reading field curve for oscillating-mirror scanners with heating The reading field curve applies for the reading conditions stated above (see table 15.13). Leuze electronic GmbH + Co. KG BCL 608...
L: Ultra Low Density (very large distances) Beam exit: 0: Perpendicular 2: Front With heating NOTE A list with all available device types can be found on the Leuze electronic website at www.leuze.com. 16.2 Type overview Table 16.2: BCL 608 part numbers Part no.
USB cables 50107726 KB USB-Service USB service cable External parameter memory 50108833 USB Memory Set External USB parameter memory Mounting devices 50027375 BT 56 Mounting device for rod 50111224 BT 59 Mounting bracket Leuze electronic GmbH + Co. KG BCL 608...
EOF TRANSM. BLOCK End of data transmission block CANCEL Invalid END OF MEDIUM End of medium SUBSTITUTE Substitution ESCAPE Escape FILE SEPARATOR File separator GROUP SEPARATOR Group separator RECORD SEPARATOR Record separator Leuze electronic GmbH + Co. KG BCL 608...
Page 95
Number Number Number Number Number Number Number Number COLON Colon SEMICOLON Semicolon < LESS THAN Less than EQUALS Equals > GREATER THAN Greater than QUESTION MARK Question mark COMMERCIAL AT Commercial AT Leuze electronic GmbH + Co. KG BCL 608...
Page 96
Capital letter Capital letter Capital letter OPENING BRACKET Opening bracket REVERSE SLANT Reverse slant CLOSING BRACKET Closing bracket CIRCUMFLEX Circumflex UNDERSCORE Underscore ‘ GRAVE ACCENT Grave accent Lower case letter Lower case letter Leuze electronic GmbH + Co. KG BCL 608...
Page 97
Lower case letter Lower case letter Lower case letter Lower case letter Lower case letter OPENING BRACE Opening brace VERTICAL LINE Vertical line CLOSING BRACE Closing brace TILDE Tilde DELETE (RUBOUT) Delete Leuze electronic GmbH + Co. KG BCL 608...