Bar code positioning system - profibus dp (80 pages)
Summary of Contents for Leuze BCL34
Page 1
Barcode reader T E C H N I C A L D E S C R I P T I O N...
Page 2
Leuze electronic GmbH + Co. KG P.O. Box 1111, D- 73277 Owen / Teck Tel. +49(0) 7021/ 573-0, Fax +49(0)7021/ 573-199 info@leuze.de • www.leuze.com Sales and Service Germany Sales Region East Sales Region North Sales Region South Phone 035027/629-106 Phone 07021/573-306...
Page 5
Measures to be performed prior to the initial commissioning ........... 94 10.2 Function Test ........................94 10.2.1 Service Operating Mode......................95 Maintenance ........................95 11.1 General Maintenance Information..................95 11.2 Repairs, servicing ......................95 Appendix ........................... 96 12.1 EU Declaration of Conformity .................... 96 Leuze electronic BCL 34...
Page 6
Figure 8.2: Relative position of the barcode in the scanner beam................77 Table 9.1: Device parameters for example configuration 2.................90 Table 9.2: Device parameters for example configuration 3.................93 Table 9.3: Module parameters for example configuration 3................93 BCL 34 Leuze electronic...
Notice! You can find the corresponding declaration of conformity in the appendix of the manual. The manufacturer of the product, Leuze electronic GmbH & Co KG in D-73277 Owen/Teck, possesses a certified quality assurance system in accordance with ISO 9001.
The barcode reader BCL 34 is intended especially for the following areas of application: • labelling and packaging machines • space-critical barcode reading tasks • storage and conveying engineering, in particular for object identification on fast- moving conveyor belts • pharmaceutical industry BCL 34 Leuze electronic...
The BCL 34 uses a laser diode with low power in the visible red light range with an emitted wavelength of 650 … 690nm. CAUTION - the use of operating and adjusting devices other than those specified here or carrying out of differing procedures may lead to dangerous exposure to radi- ation! Leuze electronic BCL 34...
Page 10
Danger warning symbol Warning laser discharge Warning unlocked protective housing Warning and certification sign Name plate Figure 2.1: Attachment of the sticky labels with warning notices at the BCL 34 BCL 34 Leuze electronic...
Scanning beam(s) 10° all dimensions Read distance in mm Figure 3.1: Beam exit and device arrangement of the BCL 34 Notice! During installation, the working range of the reading field curve must be taken into account. Leuze electronic BCL 34...
Page 12
A (N) SWOUT GND 3 VCC 1 B (P) B (P) SWIN Socket connector Plug connector Plug connector (B coded) (B coded) (A coded) Figure 3.3: BCL 34 with MS 34 103/MS 34 105 - Connection PWR BCL 34 Leuze electronic...
Page 13
As soon as the BCL 34 is addressed and configured correctly and the PROFIBUS functions, the status LED at the MS 34 104 or MS 34 105 lights up in green. Leuze electronic BCL 34...
Page 14
The BCL 34 can be accessed via the MSD 1 101 using the service interface. Notice! Changes which were made via the service interface on the BCL 34 are lost following initial- isation on the PROFIBUS. BCL 34 Leuze electronic...
When the path from the scanner to the reflector has cleared, the read procedure has completed and the scanning beam is reduced and again directed onto the reflector. The reading gate is closed. Leuze electronic BCL 34...
In addition, the MS 34 105 offers the following interfaces: • Service interface (SERVICE) • 1 further switching input and output each (SW IN/OUT) Figure 4.3: MS 34 103 Further information on the modular hoods with integrated connectors may be found in the following chapters. BCL 34 Leuze electronic...
< 16 characters, one line is used and two results are displayed Address Size Designation Value Range Standard 1: single line (two results) 2: double line Byte lcd_output_format 2: double line (one result) (one result visible) 0: depending on the size Leuze electronic BCL 34...
Page 18
PROFIBUS are displayed with a white background. If these parameters were changed, they are stored in one of the available parameter mem- ories in the MS 34. They are, thus, safely stored even if a BCL 34 is replaced. BCL 34 Leuze electronic...
405g 160g with heating: 480g Dimensions (W x H x D) without heating: 120 x 90 x 43mm 38 x 90 x 39mm with heating: 120 x 90 x 52mm Housing diecast aluminium diecast zinc Leuze electronic BCL 34...
LED states MS 34 103 / MS 34 105 Note: The LED remains off until the BCL 34 is recognised by the PROFIBUS. Only after the PROFIBUS has addressed the BCL 34 for the first time do the following status descriptions apply. BCL 34 Leuze electronic...
Figure 5.1: BCL 34 with MS 34 105 5.3.1 Dimensioned and Connection Drawings BCL 34 Rear view Plan view Plan view (without heating) (with heating) all dimensions in mm Figure 5.2: Dimensioned drawing of the BCL 34 Leuze electronic BCL 34...
Page 22
1) The total length of the barcode reader + hood with A = Barcode reader integrated connectors + connection plug is approx. all dimensions in mm Figure 5.3: Dimensioned drawing MS 34 103 / MS 34 105 BCL 34 Leuze electronic...
2/5 interleaved, ratio = 1:2.5, label class A. Reading curves BCL 34 without heating with M optics Reading distance [mm] m=0,2 m=0,3 m=0,5 Figure 5.4: BCL 34 … 100: Reading field, M optics (medium density, normal distance) BCL 34 Leuze electronic...
Page 25
BCL 34 … 100: Reading field, F optics (low density, normal distance) Reading curves BCL 34 without heating with L optics -100 -150 -200 Reading distance [mm] m=0,35 m=0,5 m=0,8 Figure 5.6: BCL 34 … 100: Reading field, L optics (low density, long distance) Leuze electronic BCL 34...
Page 26
The actual reading field for an ink-jet application must be checked for the respective application. -100 -150 m=0,5 Reading distance [mm] m=0,8 Figure 5.7: BCL 34 … 100: Reading field, J optics (for ink-jet applications) BCL 34 Leuze electronic...
Page 27
BCL 34 … 100 H: Reading field, M optics (medium density, normal distance) Reading curves BCL 34 with heating with F optics -100 Reading distance [mm] m=0,3 m=0,5 m=0,8 Figure 5.9: BCL 34 … 100 H: Reading field, F optics (low density, normal distance) Leuze electronic BCL 34...
Page 28
Specifications Reading curves BCL 34 with heating with L optics -100 -150 -200 Reading distance [mm] m=0,35 m=0,5 m=0,8 Figure 5.10: BCL 34 … 100 H: Reading field, L optics (low density, long distance) BCL 34 Leuze electronic...
The reading gate is closed. Notice! autoReflAct does not function if the bar codes which are to be read are put on reflecting surfaces, e.g. foils. Leuze electronic BCL 34...
Page 30
2000 500 03192 TKS 50x50 1000 500 22814 Table 5.5: Examples of reflectors which may be used *) Reflective tape no. 2 is included Application example: automatic reflector activation Reflector Figure 5.12: Reflector arrangement for autoReflAct BCL 34 Leuze electronic...
Accessories / Order Designation Accessories / Order Designation Accessories Notice! Products from Leuze electronic GmbH & Co KG can be ordered from any of the sales and service offices listed on the back page of this operating manual. Designation Order No.
• The device has a service interface in the form of a 9-pin sub-D connector (pin assignment: 2=RxD, 3=TxD, 5=GND). Transmission in the standard Leuze format 9600/8/Non/1 frame STX/…/CR/LF. • Connection to the PC via null modem cable • All parameters of the BCL 34 are accessible via the service interface.
Accessories / Order Designation A LED indicator B Device connector M12, 8-pin all dimensions in mm Figure 6.1: Modular Service Display MSD 1 101 Leuze electronic BCL 34...
B Rods Ø 16 … 20mm Figure 6.2: Mounting device BT 56 6.1.3 Connection cable KB 034 2000 A special connection cable of 2m length is available for the connection between MS 34 105 and MSD 1 101. BCL 34 Leuze electronic...
Device name plate BCL 34 Save the original packaging for later storage or shipping. If you have any questions concerning your shipment, please contact your supplier or your local Leuze electronic sales office. Observe the local regulations regarding disposal and packaging. Cleaning Clean the glass window of the BCL 34 with a soft cloth before mounting.
Mounting Accessories The mounting system BT 56 is available for installation. It may be ordered separately from Leuze electronic. For order numbers, see table 6.1 "Accessories / Order Designation" on page 30. MountingBCL 34 There are two basic types of mounting arrangements for the BCL 34: •...
For highly reflective surfaces, this angle may be wid- ened by tilting the BCL. 10˚ Minimum reading dis- tance, depending on the optical system used (see reading curves) all dimensions in mm Figure 7.3: Beam exit on BCL 34 Leuze electronic BCL 34...
Page 38
• mount in such a way that the device is protected from draughts; mount additional shields if necessary. • when using outdoors, we recommend mounting in an additional protective housing. Application example Figure 7.4: Application example "conveyor chain" BCL 34 Leuze electronic...
Be sure that the functional earth is connected correctly. Unimpaired operation is only guar- anteed when the functional earth is connected properly. If faults cannot be corrected, the device should be removed from operation and protected against possible use. Leuze electronic BCL 34...
/INT /SERV VOUT BUS OUT HOST/BUS IN SWIN SWOUT SWIN Socket connector Plug connector Plug connector (B coded) (B coded) (A coded) Figure 7.6: Pin assignment BCL 34 with MS 34 103 / MS 34 105 BCL 34 Leuze electronic...
Page 41
Only use sensors without switching output on pin 2 or sensor wiring configured without pin 2, as the switching output is not protected against feedback. For example, having the inverted sensor output incident on pin 2 leads to erroneous behaviour of the switching out- put. Leuze electronic BCL 34...
Contact assignment see page 41. Notice! It is recommended to connect the drain wire also to Pin 5 of the PROFIBUS connector. This ensures proper potential equalisation between the two connected devices. BCL 34 Leuze electronic...
In the standard setting, you can trigger a reading action via the switching input connection SWIN by connecting SWIN (pin 4) and VOUT (pin 1). Likewise, the BCL 34 can be activated via a Leuze sensor that is connected to the MS 34 105 through a standard sensor cable. Switching output The switching output connection between SWOUT (pin 2) and GND (pin 3) is normally open.
• Release 6 and above together with Comprofibus software Release 3 and above Here, the function block FB 192 must be integrated, which is used to transmit the consistent data. S5 with IM 308B With the IM 308B consistent data transmission must be programmed via load transfer commands. BCL 34 Leuze electronic...
These are directly related to the parameter described. These cross references must be observed during configuration. The individual modules are numerically labelled from 1 … 50. The parameters and input/output data within a module are alphanumerically labelled from … Leuze electronic BCL 34...
Page 48
2/5 Interleaved Code 39 EAN8, EAN13 Code128 Parameter (T1) (T2) (T3) (T4) Number-of-digits mode Enumeration Range Enumeration Range Number of digits 1 Digits 2 Number of digits 3 Table 8.2: Code type and code length, Tables 1-4 BCL 34 Leuze electronic...
Automatic reading activation Module 15 AutoControl Automatic monitoring of the reading properties Reference Code Com- Activation of reference code comparison and specifica- parison tion of the mode of operation Table 8.3: Overview of the project modules Leuze electronic BCL 34...
Page 50
Alignment mode 2 Function for device positioning (output in %) Switching output Additional parameters for the switching output expansion (Module 14) RS 232 Controls the data output on the serial interface Table 8.3: Overview of the project modules BCL 34 Leuze electronic...
Check digit output Code 39 in Module 7 becomes active only if Code 39 has been enabled under Code type or in Module 1 … 4 under Code type as the code type to be decoded. Leuze electronic BCL 34...
If several barcodes are read in a reading gate, these barcodes are transmitted in sequence in order to save memory in the controller. This requires a handshake, which is achieved by using the input and output data. BCL 34 Leuze electronic...
Page 53
1 -> 0: Data has been processed Control bit signals that the data have by the master 20 or – been processed by the master. 0 -> 1: Data has been processed 21…27 Acknowledge by the master Output data length: 1 byte Leuze electronic BCL 34...
18a or and no data was found during the sub- 0 … 60,000 Scans termination sequent number of scans defined in the after scans parameter. without data Parameter length: 8 bytes Input Data none Output Data none BCL 34 Leuze electronic...
Specifies whether the EAN 128 symbol- 0: not output ogy identifier ([C1) is included in the – (Do not) output 1: output decoding result or not. symbology identifier Parameter length: 3 bytes Input Data none Output Data none BCL 34 Leuze electronic...
The parameter specifies the switch-on 0 … 99 Laser start position of the laser. position The parameter specifies the switch-off Laser stop 0 … 100 position of the laser. position Parameter length: 2 bytes Input Data none Output Data none Leuze electronic BCL 34...
Pharmacode. I.e, this is the maximum possible deviation ratio of the gaps that can occur. The parameter specifies the reading direction for the 0: Normal Reading – decoding 1: Inverse direction Parameter length: 5 bytes Input Data none Output Data none BCL 34 Leuze electronic...
The parameter activates (1) an internal check 0: do not consider to see whether there is a difference in position – Position between 1: do consider two labels between two labels. Parameter length: 4 bytes Input Data none Output Data none Leuze electronic BCL 34...
Fill mode sion length The parameter defines the character which is 0 … 255 45 ("-") – used for filling up the data areas. Fill character Parameter length: 23 bytes Input Data none Output Data none BCL 34 Leuze electronic...
Parameter length: 10 bytes Input Data Input Data Description Rel. Data Value Range Default Unit CR to addr. type module State of the signal of the switching – State input Input data length: 1 byte Output Data none Leuze electronic BCL 34...
In addition, both values must always be specified, i.e., for the switch-on function and the switch-off function, e.g., switch-on function "positive reference code comparison 1" and switch- off function "negative reference code comparison 1". Input Data none BCL 34 Leuze electronic...
Page 63
PROFIBUS edge Resets the event counter (Module 49) of 0 -> 1: Perform reset – Reset Event the activation function [AF] back to zero 1 -> 0: No function Counter Output data length: 1 byte Leuze electronic BCL 34...
– Save reflector alignment in the parameter set. position Output data length: 1 byte This bit should only be set from 0 -> 1 if the status "reflector detected" (0) is shown in the input data. BCL 34 Leuze electronic...
16 1: Quality bad result was not reached. This value is the current average of the scan quality. unsign8 0 … 100 – Scan quality Input data length: 2 byte Output Data none Leuze electronic BCL 34...
1) page 68. 0 … FFh The parameter defines the components and the Settings logic for code comparison for comparison unsign8 see "Explanations regarding – (comparison function 2. the parameter "Settings"" function 2) on page 66. BCL 34 Leuze electronic...
Page 67
Value Range Default Unit CR to module – – – – – – Reserved Output data length: 1 byte Notice! 1 byte output data was reserved for future applications. Currently, no function is assigned to this byte. Leuze electronic BCL 34...
Page 68
= 1 Comparison positive if RBC length equal to barcode length mtc = 0 Comparison positive if RBC model not equal to barcode model mtc = 1 Comparison positive if RBC model equal to barcode model BCL 34 Leuze electronic...
Page 69
The comparison result is positive if each decoded barcode corresponds to the RBC it was com- pared with. (Number of the received barcodes must correspond to the number deposited in the parameter "number of barcodes per reading gate" (Module 5)). Leuze electronic BCL 34...
Page 70
The following table shows the individual conditions: Comparison is positive if … Barcode != RBC Barcode == RBC Barcode > RBC Barcode >= RBC Barcode < RBC Barcode <= RBC RBCn <= Barcode <= RBCn+1 Barcode < RBCn Barcode > RBCn+1 BCL 34 Leuze electronic...
Signal, triggers a system reset if the level 0 -> 1: Reset – changes from 0 to 1. System reset 0: Standby off Signal, activates the standby function – 1: Standby on Standby Output data length: 1 byte Leuze electronic BCL 34...
Signal, triggers a system reset if the level – changes from 0 to 1. 0 -> 1: Reset System reset 0: Standby off Signal, activates the standby function – 1: Standby on Standby Output data length: 1 byte BCL 34 Leuze electronic...
If one of the modules 21 to 27 is used, the status information of the selected module must also be used. The modules only work consistently or synchronously in themselves. Parameters none Leuze electronic BCL 34...
Page 74
Barcode information with a length of 28 x 2 … 0 … FFh Data consistently 28 bytes. unsign8 Input data length: 2 bytes consistently + 4 … 28 bytes of barcode information depending on the module Output Data none BCL 34 Leuze electronic...
Delimiter lowing read result could be transmitted to the control: “02.10.2008“; without delimiter (value 0) this read result would be transmitted to the control as “02102008“. Parameter length: 1 byte Input Data none Output Data none Leuze electronic BCL 34...
0 -> 1: Data has been processed by Control bit indicates that the frag- the master ment has been processed by the – 1 -> 0: Data has been processed by Acknowledge master the master Output data length: 2 bytes consistently BCL 34 Leuze electronic...
Rel. addr. Data type Value Range Default Unit CR to module Reading gate activations since system start. 0 … 1 unsign16 0 … 65535 – Reading Gate Activations Input data length: 2 bytes consistently Output Data none Leuze electronic BCL 34...
Number of scans for the reading 0 … 1 unsign16 If the range is exceeded, the value – Scans in the gate. remains at 65535 reading gate Input data length: 2 bytes consistently Output Data none BCL 34 Leuze electronic...
21% of the beam length. A value of 18040 0 … 1 unsign16 1000 … 25000 – Code Position identifies the start of the barcode to be located at 71%. Input data length: 2 bytes consistently Output Data none Leuze electronic BCL 34...
CR to addr. module Number of scans between the first and last 0 … 1 unsign16 0 … 65535 – Scans per barcode detecting of the barcode Input data length: 2 bytes consistently Output Data none BCL 34 Leuze electronic...
Input Data Description Rel. Data Value Range Default Unit CR to addr. type module The decoding quality of the transmitted bar- unsign8 0 … 100 Decoding quality code Input data length: 1 byte Output Data none Leuze electronic BCL 34...
Input Data Description Rel. Data Value Range Default Unit CR to addr. type module Number of digits of the transmitted barcode unsign8 0 … 48 – Number Of Digits Input data length: 1 byte Output Data none BCL 34 Leuze electronic...
Output Data Description Rel. Data Value Range Default Unit CR to addr. type module Signal, activates the alignment 0 -> 1: On – Alignment mode 1 -> 0: Off mode Output data length: 4 byte consistently BCL 34 Leuze electronic...
Description Rel. Data Value Range Default Unit CR to addr. type module Reset of parameters to 0 -> 1: reset the parameters – factory settings 1 -> 0: standard operation PC20_Over_Profibus Output data length: 1 byte Leuze electronic BCL 34...
Signal activates and deactivates the align- 0 -> 1: On ment mode for optimum alignment of the – Alignment 1 -> 0: Off Mode BCL with the barcode Output data length: 1 byte BCL 34 Leuze electronic...
14 switch-off function, or if the counter should – Reset mode 1: Comparative value be automatically reset after the comparative (event counter) reached value is reached. Parameter length: 8 bytes Leuze electronic BCL 34...
Page 88
The – 1 -> 0: Event counter value-toggle bit bit is reset to the init. value by resetting the exceeded again (event counter) event counter. Input data length: 1 byte Output Data none BCL 34 Leuze electronic...
(RS 232). The baud rate, data format, and prefix and postfix characters can be configured. In the standard configuration, the Leuze framing protocol is used. Its structure is <STX><Data><CR><LF> with data format 8 data bits, no parity and 1 stop bit (8N1) and a transmission speed of 9600 Baud.
Modules Required Include the following modules into your project: • Activations (Module • Decoding Result 16 bytes (Module 24) Parameter Settings No parameters need to be set especially. The standard parameter set provides all required functions. BCL 34 Leuze electronic...
Page 91
The data length is entered into byte 1. M 24 byte 2 = result The result Hex 3F ("?" = no read) is transmitted Internal processing of the data and signalling of Internal processing the non-reading Leuze electronic BCL 34...
Change value to: [T1] digits 1 [T2] code type Code 39 0 (no code) [T3] code type EAN8, EAN13 0 (no code) [T4] code type Code 128 0 (no code) Table 9.1: Device parameters for example configuration 2 BCL 34 Leuze electronic...
Page 93
0.2 = 1. M 23 Byte 1 = 1 The data length is entered into byte 1. M 23 byte 2 = result The result Hex 3F ("?" = no read) is transmitted. Internal processing Internal data processing Leuze electronic BCL 34...
Include the following modules into your project: • Activations (Module 18) • Decoding Result 12 byte (Module 23) • Scans With Information (Module 41) • Check Digit (Module 7) • Switching input (Module 13) • Reading Gate Control (Module 6) BCL 34 Leuze electronic...
Page 95
M 23 byte 2 to 11 = result mal if reading has been successful, 1 if barcode could not be recognised) The decoding result is transmitted in the follow- ing 10 bytes. Internal processing Internal data processing Leuze electronic BCL 34...
The significance of the individual LED states may be found in table 5.2 on page 18. Problems Should a problem persist after checking all electrical connections and settings on the devices and host, please contact a Leuze service office near you (see the back page of this operating manual). BCL 34 Leuze electronic...
11.2 Repairs, servicing Repairs to the device must only be carried out by the manufacturer. Contact your Leuze distributor or service organisation should repairs be required. For addresses, please refer to the back page of this operating manual. Leuze electronic...