4.8
Removing the Oxy-Pilot Assembly
Note: Because this appliance is fitted with an atmosphere sensing 'Oxy-
Pilot' it is not possible to replace the thermocouple separately, because the
thermocouple position is factory set to a tight tolerance. Any replacement of
parts on the pilot requires a complete new pilot assembly.
4.8.1
Remove the burner assembly as in section 4.1
4.8.2
Unscrew and remove the thermocouple retaining nut from the end of the
control tap, disconnect the ignition lead from the pilot electrode and the
two inline leads from the microswitch.
4.8.3
Unscrew and remove the two pozi-drive screws which secure the pilot
assembly to the burner. Remove the pilot.
4.8.4
Re-assemble in reverse order and carry out a gas tightness test.
4.9
Replacing the Control Cable
4.9.1
The control lever operating cable can be seen running across the base
of the fire, below the burner. To release the cable, unscrew the cable
securing screw located in the centre of the aluminium operating arm
and release the front part of the operating arm, thereby freeing the
cable from the burner. See figure 37 below.
Fig. 37
4.9.2
Hold the hexagonal control lever cable locking bush with a spanner
and unscrew the locking screw using a 2mm allen key to release the
cable from the control lever. The control cable can now be removed
from the cable guide tubes.