Chapter 2

2.0 Understanding Your Keypad

The PowerSeries Neo Alarm System supports a variety of wireless, hardwired and proximity sensor LCD, LED and Icon keypads.
All keypads come equipped with the LED status lights described in section 1 "Quick Reference". HS2LCD series keypads display
system messages on their LCD screen. HS2ICN series keypads display messages, as described in the following section. HS2LED
series keypads display messages via a series of numbered LEDs, as described in the following section. All keypad versions will
have a solid blue LED bar that is always on steady except when, if enrolled, a proximity tag is presented to and successfully read
by the keypad.

2.1 Icon and LED Keypad Symbols

HS2ICN Series
4
1
2
3
5
9
12
7
1.
Clock Digits 1, 2
2.
: (Colon)
3.
Clock Digits 3, 4
4.
1 to 8
5.
Memory
6.
Bypass
7.
Program
8.
Away
9.
Fire
10.
Stay
11.
Chime
12.
OPEN
13.
AC
14.
System Trouble
15.
Night
16.
Ready Light (green)
17.
Armed Light (red)
Note: For UL listed installations, zones can only be bypassed manually.
6
15
11
10
8
These two 7 segment clock digits indicate the hour digits when the local clock is active. Digit
2 is also used to identify the zone number as the 1 when the zone number is 100 or higher and
the OPEN or ALARM icons are active.
This icon is the hours/minutes divider and will flash once per second when the local clock is
active.
These two 7 segment displays are the minute digits when the local clock is active. The digits
3 and 4 are used to indicate the zone number for open zones or alarm in memory. These two
digits combined with the clock digit 2, scroll one zone per second from the lowest number to
the highest, when scrolling through zones.
These numbers identify troubles when [*][2] is pressed.
Indicates that there are alarms in memory.
Indicates that there are zones bypassed.
Indicates that the system is in Installer or User's programming, or that the keypad is busy, and
the LED will flash in cadence of 250ms ON and 250ms OFF. If Access Code is required,
while accessing star menus, this LED is ON and solid to indicate that the code is required.
Indicates that the panel is armed in the Away Mode.
Indicates that there are fire and/or CO alarms in memory.
Indicates that the panel is armed in the Stay Mode.
This icon turns on when the Chime function key is pressed to enable Door Chime on the sys-
tem. It will turn off when the chime function key is pressed again to disable Door Chime.
This icon is used with clock digits 1 and 2 to indicate activated zones (not alarm) on the sys-
tem. When zones are opened, the OPEN icon will turn on, and 7 segment displays 1 and 2
will scroll through the violated zones.
Indicates that AC is present at the main panel.
Indicates that a system trouble is active.
Indicates that the panel is armedin the Night Mode.
If the Ready light is on, the system is ready for arming. If the toggle of the Ready LED
flashes for Force Arming enabled, the LED flashes with force armable zones open on the
partition.
If the Armed light is on, the system has been armed successfully.
- 6 -
HS2LED Series
5
9
16
7
6
17
14
13