Closed Heat Exchanger - Kohler 9EKOZD Installation Manual

Marine generator sets
Table of Contents

Advertisement

3.2.5

Closed Heat Exchanger

A closed heat exchanger is the best cooling method for
most applications.
See Figure 3-6 for a typical
installation. Provide space to access the water-cooled
exhaust manifold pressure cap.
2
3
1. Engine block
2. Thermostat
3. Engine-driven water pump
4. Engine-driven seawater pump
5. Seawater strainer (customer-supplied)
6. Seacock (customer-supplied)
Figure 3-6 Typical Closed/Heat Exchanger Cooling System
16
Section 3 Cooling System
All manuals and user guides at all-guides.com
1
8
4
5
6
7
10. Heat exchanger (located inside manifold)
11. Silencer (customer-supplied)
12. Exhaust outlet (customer-supplied)
9
10
11
Seawater
Freshwater (Coolant/Antifreeze)
7. Intake strainer (customer-supplied)
8. Water-cooled manifold
9. Exhaust mixer elbow
12
TP-6773 5/12a