4.3.2

Mid/Below-Waterline Installation

Follow USCG Regulations for installing an antisiphon
provision to prevent raw water entry into the engine.
Use the siphon break if the exhaust manifold outlet is
located less than 23 cm (9 in.) above the waterline when
the craft is loaded to maximum capacity. Install the
siphon break at least 31 cm (1 ft.) above the waterline
using the instructions provided with the siphon break kit.
Note: An improperly installed siphon break will cause
engine damage and may void the warranty.
Install the siphon break above the highest point in the
exhaust line between the heat exchanger and the
exhaust mixer. See Figure 4-4 for the siphon break
connection. Support the siphon break and hoses to
maintain their position and function. Allow a slight offset
to clear the stringers or other permanent structures.
Protect the siphon break air inlet from dirt and debris.
Note: To prevent water leakage on the generator set, do
not mount the siphon break directly over the
generator set.
Note: Ensure that the siphon break's cap is tight before
operating the generator set.
Models without Sound Shield
6EKOD/5EFKOD
9EKOZD/7EFKOZD
11EKOZD/9EFKOZD (1 Phase)
11EKOZD/9EFKOZD (3 Phase)
Figure 4-5 Exhaust Hose Sizes
20
Section 4 Exhaust System
All manuals and user guides at all-guides.com
Figure 4-4 Siphon Break Connection, Typical
Mount a typical silencer's base no more than 1.2 m (4 ft.)
below the highest point in the exhaust line. Attach a
separate wood mounting base to the hull stringers or
other
manufacturer's recommendation for securing the
silencer to the hull. Mount the silencer with the outlet not
more than 3 m (10 horizontal ft.) from the engine's
exhaust manifold outlet. Use a USCG-type certified
marine exhaust hose.
Models with Sound Shield
6EKOD/5EFKOD
9EKOZD/7EFKOZD
11EKOZD/9EFKOZD (1 Phase)
11EKOZD/9EFKOZD (3 Phase)
1
1. Heat exchanger (located inside the manifold)
2. Exhaust mixer
3. Cut hose and connect siphon break and hardware (rotate
the fitting on the mixer if necessary)
suitable
structures.
Exhaust Hose
Diameter
mm (in.)
51 (2.0)
2
3
Use
the
silencer
TP-6773 5/12a