Circuit Protection; Circuit Breaker Considerations - Kohler 9EKOZD Installation Manual

Marine generator sets
Table of Contents

Advertisement

6.2 Circuit Protection

The AC circuit breakers (optional) protect the wiring
from the AC circuit breakers to the vessel's distribution
panel. AC circuit breakers trip when they detect a fault in
the output circuit.
After correcting the fault, reset the AC circuit breaker(s)
by placing them in the ON position. Restart the unit. Do
not start the unit under load. See Figure 6-3 for AC
circuit breaker ratings. The unit's voltage configuration
determines the circuit breaker selection.
Note: Circuit breaker ampere rating and availability are
subject to change.
6.2.1

Circuit Breaker Considerations

Mounting location. Mount the circuit breakers in the
generator set's junction box. See Section 6.2.2.
Sizing.
Use the generator set voltage/frequency
configuration
to
determine
amperage. If the generator set voltage configuration
changes, change the circuit breaker to provide optimum
protection.
For
circuit
breaker
information, contact an authorized distributor/dealer.
Have a qualified electrician or technician install circuit
breakers and reconnect the generator set. Comply with
all governing standards and codes.
30
Section 6 Electrical System
All manuals and user guides at all-guides.com
the
circuit
breaker
application
and
selection
Number
Voltage
of Poles
Amps
18
480
20
250
22
250
23
480
25
250
27
250
30
250
250
250
35
480
250
40
250
42
250
250
50
250
85
250
100
250
Figure 6-3 AC Circuit Breaker Ratings, Listed By
Amps
WARNING
Accidental starting.
Can cause severe injury or death.
Disconnect the battery cables before
working
on the
Remove the negative (--) lead first
when disconnecting the battery.
Reconnect the negative (--) lead last
when reconnecting the battery.
Disabling the generator set.
cause severe injury or death.
generator set or connected equipment, disable the generator
set as follows: (1) Move the generator set master switch to the
OFF position. (2) Disconnect the power to the battery charger.
(3) Remove the battery cables, negative (--) lead first.
Reconnect the negative (--) lead last when reconnecting the
battery. Follow these precautions to prevent starting of the
generator set by an automatic transfer switch, remote
start/stop switch, or engine start command from a remote
computer.
Model(s)
3
9EFKOZD (3 ph.)
3
11EKOZD (3 ph.)
2
5EFKOD
3
11EKOZD (3 ph.)
2
6EKOD
1
5EFKOD
1
7EFKOZD
1
7EFKOZD
2
7EFKOZD
3
11EKOZD (3 ph.)
1
9EFKOZD (1 ph.)
3
11EKOZD (3 ph.)
9EKOZD &
2
9EFKOZD (1 ph.)
2
11EKOZD (1 ph.)
1
6EKOD
1
9EKOZD
1
11EKOZD (1 ph.)
generator set.
Accidental starting can
Before working on the
TP-6773 5/12a

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

6ekod11ekozd5efkod7efkozd9efkozd

Table of Contents