Gree SAP24HP230V1A Service Manual page 74

Hide thumbs Also See for SAP24HP230V1A:
Table of Contents

Advertisement

Service Manual
Display Method of Indoor Unit
Malfunction
Dual-8
NO.
Name
Code
Display
Gathering
11
Fo
refrigerant
Indoor
ambient
temperature
12
F1
sensor is
open/short
circuited
Indoor
evaporator
temperature
13
F2
sensor is
open/short
circuited
Outdoor
ambient
temperature
14
F3
sensor is
open/short
circuited
Outdoor
condenser
temperature
15
F4
sensor is
open/short
circuited
Outdoor
discharge
temperature
16
F5
sensor is
open/short
circuited
Limit/
decrease
17
frequency
F6
due to
overload
Decrease
frequency
18
F8
due to
overcurrent
Installation and Maintenance
Display Method of Outdoor
Indicator has 3 kinds of
Indicator Display (during
display status and during
blinking, ON 0.5s and OFF
blinking, ON 0.5s and OFF
0.5s)
0.5s
Operation
Cool
Heating
Indicator
Indicator
Indicator
Indicator
OFF 1S
and blink
17 times
Unit
Yellow
Red
Green
Indicator
Indicator
When the outdoor unit receive
signal of Gathering refrigerant
,the system will be forced to
run under cooling mode for
gathering refrigerant
During cooling and drying
operation, indoor unit operates
while other loads will stop;
during heating operation,
the complete unit will stop
operation.
AC stops operation once
reaches the setting
temperature. Cooling, drying:
internal fan motor stops
operation while other loads
stop operation; heating: AC
stop operation
During cooling and drying
OFF 1S
operating, compressor stops
and
while indoor fan operates;
blink
During heating operation,
6 times
the complete unit will stop
operation
During cooling and drying
OFF 1S
operation, compressor stops
and
while indoor fan will operate;
blink
During heating operation,
5 times
the complete unit will stop
operation.
During cooling and drying
operation, compressor will sop
OFF 1S
after operating for about 3
and
mins,
blink
while indoor fan will operate;
7 times
During heating operation, the
complete unit will stop after
operating for about 3 mins.
OFF 1S
All loads operate normally,
and
while
blink
operation frequency for
3 times
compressor is decreased
OFF 1S
All loads operate normally,
and
while
blink
operation frequency for
once
compressor is decreased
A/C status
Possible Causes
Nominal cooling mode
1. Loosening or bad contact of
indoor ambient temp. sensor and
mainboard terminal.
2. Components in mainboard fell
down leads short circuit.
3. Indoor ambient temp. sensor
damaged.(check with sensor
resistance value chart)
4. Mainboard damaged.
1. Loosening or bad contact of
Indoor
evaporator temp. sensor and
mainboard terminal.
2. Components on the mainboard
fall
down leads short circuit.
3. Indoor evaporator temp. sensor
damaged.(check temp. sensor
value
chart for testing)
4. Mainboard damaged.
Outdoor temperature sensor
hasnt been connected well or
is damaged. Please check it by
referring to the resistance table for
temperature sensor)
Outdoor temperature sensor
hasnt been connected well or
is damaged. Please check it by
referring to the resistance table for
temperature sensor)
1.Outdoor temperature sensor
hasnt been connected well or is
damaged. Please check it by
referring to the resistance table for
temperature sensor)
2.The head of temperature sensor
hasnt been inserted into the copper
tube
Refer to the malfunction analysis
(overload, high temperature
resistant)
The input supply voltage is too low;
System pressure is too high and
overload
71