1. In cooling mode:
1.1 When the initial set temperature is16-23°C(60.8~73.4°F),the temperature will rise 1°C(1.8°F) by every hour after sleep function is set;the
temperature will not change after rising 3°C(5.4°F) ;after running for 7hours,the temperature will decrease1°C(1.8°F) and it will not change
after that.
1.2 When the initial set temperature is 24-27°C(75.2~80.6°F),the temperature will rise 1°C(1.8°F) by every hour after sleep function is set; the
temperature will not change after rising 2°C(3.6°F) ;after running for 7 hours, the temperature will decrease 1°C(1.8°F) and it will not change
after that.
1.3 When the initial set temperature is 28-29°C(82.4~84.2°F),the temperature will rise 1°C(1.8°F) by every hour after sleep function is set; the
temperature will not change after rising 1°C(1.8°F) ; after running for 7 hours, the temperature will decrease 1°C(1.8°F) and it will not change
after that.
1.4 When the initial set temperature is 30°C(86°F) , the unit will keep on running at this temperature; after running for 7 hours, the temperature
will decrease 1°C(1.8°F) and it will not change after that.
Relationship between set temperature and running time:
2. In heating mode:
2.1 When the initial set temperature is 16°C(60.8°F), the unit will keep on running at this temperature;
2.2 When the initial set temperature is 17-20°C(62.6~68°F), the temperature will decrease 1°C(1.8°F) by every hour after sleep function is set;
the temperature will not change after decreasing 1°C(1.8°F);
2.3 When the initial set temperature is 21-27°C(69.8~80.6°F), the temperature will decrease 1°C(1.8°F) by every hour after sleep function is
set; the temperature will not change after decreasing 2°C(3.6°F);
2.4 When the initial set temperature is 28-30°C(82.4~86°F), the temperature will decrease 1°C(1.8°F) by every hour after sleep function is set;
the temperature will not change after decreasing 3°C(5.4°F);
Relationship between set temperature and running time:
(6) Indoor Fan Control
Indoor fan could be set at ultra-high, high, medium, low speed by wireless remote controller and operated as that speed.
Auto fan speed could be set as well, indoor fan will operate under auto fan speed as following:
Technical Information
Initial Temp.
0(start)
1
2
16
17
18
17
18
19
18
19
20
19
20
21
20
21
22
21
22
23
22
23
24
23
24
25
24
25
26
25
26
27
26
27
28
27
28
29
28
29
29
29
30
30
30
30
30
Initial Temp.
0(start)
1
2
16
16
16
17
16
16
18
17
17
19
18
18
20
19
19
21
20
19
22
21
20
23
22
21
24
23
22
25
24
23
26
25
24
27
26
25
28
27
26
29
28
27
30
29
28
Running time(T)
3
4
5
19
19
19
20
20
20
21
21
21
22
22
22
23
23
23
24
24
24
25
25
25
26
26
26
26
26
26
27
27
27
28
28
28
29
29
29
29
29
29
30
30
30
30
30
30
Running time(T)
3
4
5
16
16
16
16
16
16
17
17
17
18
18
18
19
19
19
19
19
19
20
20
20
21
21
21
22
22
22
23
23
23
24
24
24
25
25
25
25
25
25
26
26
26
27
27
27
6
7
8
19
18
18
20
19
19
21
20
20
22
21
21
23
22
22
24
23
23
25
24
24
26
25
25
26
25
25
27
26
26
28
27
27
29
28
28
29
28
28
30
29
29
30
29
29
6
7
8
16
16
16
16
16
16
17
17
17
18
18
18
19
19
19
19
19
19
20
20
20
21
21
21
22
22
22
23
23
23
24
24
24
25
25
25
25
25
25
26
26
26
27
27
27
49