Troubleshooting - Kärcher PC 60T Original Instructions Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 11
Danger
Risk of injury! The main switch is to be
switched off while carrying out any repairs
or maintenance jobs.
If malfunction can not be fixed, the de-
vice must be checked by customer serv-
ice.
Fault
Appliance is not running
The indicator lamp for the
heater will light up red
The indicator lamp for the
operating status will light up
red
Turntable does not turn
Bad cleaning result
The indicator lamp for tem-
perature will light up red

Troubleshooting

Possible cause
Main switch is switched off.
Mains fuse in the power supply is
faulty.
Timer lapsed.
Device hood has not been closed
properly.
Filling level too low.
There is no voltage in the machine.
Water shortage
Filling level sensor is faulty.
Turntable overloaded.
Load too heavy or too large.
Turntable loaded unevenly.
Turntable defective.
Cleaning time too short.
Detergent liquid is dirty.
Nozzles are blocked.
Filter blocked (optional).
Oil percentage in the detergent liquid
is too high.
Pump does not work
Wrong rotating direction of the pump
motor.
Temperature too low.
Temperature limiter has got triggered. Allow the device to cool; remove the cause of
Remedy
Turn on the main switch.
Replace the fuse.
Set the cleaning time.
Press the handle downward.
Fill water into the detergent container until
the indicator lamp "Heater" lights up green or
shuts off.
Check electrical mains.
Fill water into the detergent container until
the indicator lamp "Heater" lights up green or
shuts off.
Replace filling level sensor.
Take some load off the turntable or reposition
the parts. To reset a fault, briefly open the
machine hood and close it or briefly turn the
timer switch to "0".
Remove some parts.
Correct the load arrangement in the basket. Operator
Check whether the turntable turns while it is
not loaded. If not, call customer service.
Increase the cleaning time.
Replace the detergent liquid.
Clean the nozzles.
Clean or replace the filter inlay.
Turn on the skimmer.
Check motor protection switch.
Rectify the electrical connection. The fan of
the pump motor must rotate in the direction of
the arrow.
Set the thermostat to a higher level.
Check thermostat or temperature limiter; re-
place, if required.
the fault. Reset the temperature limiter in the
heater switch cabinet by pressing the reset
button. Contact Customer Service if the fault
recurs.
7
-
EN
of whom
Operator
Operator
Operator
Operator
Operator
Electrician
Operator
Customer Service
Operator
Operator
Operator
Operator
Operator
Operator
Operator
Operator
Operator
Electrician
Operator
Customer Service
Operator
17