Assembly

5.4 Mounting the sensor

5.4.1 Overview of sensors

5.4.2 Mounting MMS 30 magnetic switch

26
05.00 | SRU-plus 63 | Assembly and Operating Manual | en | 389445
NOTE
Observe the assembly and operating manual of the sensor for
mounting and connecting.
The product is prepared for the use of sensors.
• For the exact type designations of suitable sensors, please see
catalog datasheet and
• For technical data for the suitable sensors, see assembly and
operating manual and catalog datasheet.
– The assembly and operating manual and catalog datasheet
are included in the scope of delivery for the sensors and are
available at schunk.com.
• Information on handling sensors is available at schunk.com or
from SCHUNK contact persons.
Designation
Magnetic switch MMS 30
Inductive proximity switch IN 80
1. Connect sensor and secure cable, see the Sensor Assembly and
Operating Manual.
2. Actuate air connection "A" (4), until the pinion (2) begins to
move.
The assembly swivels into the end position.
3. Slide the first sensor (6) into a groove (5).
OR: screw (1) the sensor (6) into a groove (5).
} 5.4.1 [ /