Installing/Removing Power Modules - Siemens RUGGEDCOM RX1501 Installation Manual

Hide thumbs Also See for RUGGEDCOM RX1501:
Table of Contents

Advertisement

Chapter 4
Modules
Section 4.3

Installing/Removing Power Modules

The RUGGEDCOM RX1501 supports a single power module.
Figure 23:  Power Module
1. Power Module
CAUTION!
Contamination hazard – risk of equipment damage. Prevent the ingress of water, dirts and other debris
that may lead to premature equipment failure. Always make sure slots are not left empty.
Removing a Power Module
To remove a power module, do the following:
DANGER!
Electrocution hazard – risk of serious personal injury or death. Make sure power to the module is
turned off before servicing the power supply terminal.
1.
Turn off power to the module.
2.
Loosen the screws that secure the module to the chassis until the module can be removed.
Figure 24: Removing a Power Supply
1. Chassis    2. Power Supply    3. Screws
3.
Slide the module out of the chassis.