Siemens RUGGEDCOM RX1501 Installation Manual page 27

Hide thumbs Also See for RUGGEDCOM RX1501:
Table of Contents

Advertisement

RUGGEDCOM RX1501
Installation Guide
Figure 12: DC Terminal Block Wiring – European-style (Euroblock) Terminal Block for -12P, -24P and -48P Power
Supplies
1. Not Connected    2. European-style (Euroblock) Terminal Block    3. Positive (+) Terminal    4. Negative (-) Terminal    5. Ground
Terminal
Figure 13: DC Terminal Block Wiring – Screw Terminal Block for -12P, -24P and -48P Power Supplies
1. Not Connected    2. Removable Screw Terminal Block    3. Non-removable Screw Terminal Block    4. Positive (+) Terminal   
5. Negative (-) Terminal    6. Ground Terminal
2.
Connect the positive wire from the power source to the positive (+) terminal on the terminal block.
3.
Connect the negative wire from the power source to the negative (-) terminal on the terminal block.
4.
For screw terminal blocks, install the safety cover.
Connecting Low DC Power