Other Switch/Jumper Settings - Plextor UltraPlex PX-32CSe User Manual

Plextor px-32cse cdr drives: user guide
Hide thumbs Also See for UltraPlex PX-32CSe:
Table of Contents

Advertisement

CHAPTER 6 ---- Drive Switch/Jumper/Dial Settings
Other Switch/Jumper Settings----UltraPleX
The remaining switches (external drives) and jumpers (internal drives) are:
Parity
Leave this ON. The parity check provided by the ON setting enhances the
reliability of the SCSI bus. Set to OFF only if your computer system or SCSI
controller specifically requests that parity be disabled.
Term
This enables or disables (turns ON or OFF) SCSI termination. Factory setting
is Enabled (ON). See page 19 for an explanation of SCSI termination and to
determine if you need to change this setting.
Test
Leave this OFF. It is for factory use only.
Block
Leave this OFF, unless you are working in a UNIX environment and want
to boot from your CD-ROM drive. If so, set this switch/jumper ON.
Eject
In most situations, you will want to leave this switch/jumper OFF.
However, if you are in an environment where you want to prevent others
from borrowing or stealing the disc inserted in your drive (e.g., the drive is
located in a public place where multiple users have unlimited access), you
can activate the Eject Lock feature. To do so, set this switch/jumper ON.
When this switch/jumper is ON, it is impossible to eject a disc inserted in
the drive by pressing the Eject button. A software eject command must be
issued for the disc to eject from the drive. Check your device driver manual
for instructions on how to issue a software eject command. The media lock
and eject functions can also be controlled by Plextor Manager software.
18
ULTRAPLEX OPERATION MANUAL