Multiple Units

When installing multiple MiniModule units it is
recommended you use the R FR 3005 Rack Frame 1
and/or R FR 3010 Rack Frame 2 options. Please refer
to the documentation supplied with these options
for details on electrical installation.

Settings and Control

The D VA 3120 L is configured via the integral 4-
position dip-switch and push buttons.

Switch Settings

Below the switch settings for the 4-position dip-
switch are defined. Switch function is described in
more detail after the table below.
Switch
1
2
3
4
*When in single mode the IN 1 video input is used.
Reference Manual D VA 3120 L Version1.2
BUTTONS
UP
DN
Setting
Function
ON
Single 1:6 mode *
OFF
Dual 1:3 mode
ON
Gain adjustment selected
OFF
Equalizer adjustment selected
ON
Unity selected
OFF
Unity not selected
ON
Channel 2 selected
OFF
Channel 1 selected
DIP SWITCH
OFF
ON
1
2
3
4