Page 2
Except as expressly written by LYNX Technik AG, the furnishing of this document does not give you any license to patents, trademarks, copyrights or other intellectual property of LYNX Technik AG or any of its affiliates.
LYNX Technik, with shipping charges prepaid. LYNX Technik shall pay for the return of the product to the customer if the shipment is within the country which the LYNX Technik service center is located.
Reference Manual D VD 3620 Version1.2 Regulatory information Europe Declaration of Conformity LYNX Technik AG Sandstrasse 7 D-64404 Bickenbach Germany Declare under our sole responsibility that the product TYPE: D VD 3620 To which this declaration relates is in conformity with the following...
Product Description The D VD 3620 is a high quality HD / SD digital video distribution amplifier designed primarily for broadcast and professional applications. Flexible configurations allow the D VD 3620 to be used in dual 1 to 4 applications or 1 to 8 applications.
D VD 3620 MiniModule. Figure 1- D VD 3620 Functional Diagram Module Layout Figure 2 shows the physical layout of the D VD 3620 MiniModule. Video I/O is made through standard BNC video connectors. Module configuration is set via a small dip-switch located behind a small access hole in the top of the module.
Reference Manual D VD 3620 Version1.2 Connections Video Connections The D VD3620 MiniModule is configured with standard 75 Ohm BNC connectors. Connection is self-explanatory. We recommend the use of high quality video cable for digital video connections to reduce the risk of interference or errors due to excessive cable attenuation.
Data Connection Power Connection i2C-SDA (data) + 5V i2C-SCL (clock) Male Connector (view looking into connector from front) Caution Only use the optional LYNX R PS power modules. Ensure the 5-pin power connector is locked securely in place. Page 11...
Installation Mechanical Stand Alone Operation The D VD 3620 MiniModule can be used in a stand alone application. There are two options for the use of the module in this way. a) Using the R FR 3005 Rack Frame 1 option. This allows the MiniModules to be secured onto a rack frame assembly for 19 inch rack mounting.
Reference Manual D VD 3620 Version1.2 Multiple Units Most applications will require more than one MiniModule, which can include any of the available Series 3000 MiniModule product range. There are two options for mounting multiple units. a) Using the R FR 3005 Rack Frame option. This the MiniModules to be secured onto a rack frame assembly for 19 inch rack mounting.
/ receiving the signals from the module or damage can result. Caution. Only use the optional Lynx R PS 3001 power modules. Ensure the 5-pin power connector is locked securely in place.
Once set, all settings are automatically saved in non-volatile internal memory. The module will always recall the settings used to prior to power off. The D VD 3620 is configured locally via the integral 4-position dip-switch (see fig.2). Switch Settings Below the switch settings for the 4-position dip- switch are defined.
This switch configures input 2 to be reclocked or non reclocked. ON sets reclocked OFF sets non- reclocked Factory Preset Condition The D VD 3620 is delivered preset for the following mode of operation: Mode 2 x 1:4 Input 1...
Reference Manual D VD 3620 Version1.2 Alarm/LED Status Indicators The D VD 3620 module has built in LED indicators, which serve as alarm and status indication for the module. Function is described below. The Indicators are found on the top of the module and can be seen through the access hole provided.
Reference Manual D VD 3620 Version1.2 Locate Function For large systems which have many modules in various locations we have added a utility which will help visually identify a module quickly. (When used in conjunction with the optional control system and...
Reference Manual D VD 3620 Version1.2 Specifications (D VD3620) Inputs Signal 1 or 2 Serial Digital Video. SMPTE 259M, 292M, 344 M with automatic standard detection Input Impedance 75 Ohms Input level 0.8V p-p (+-10%) Return loss 20dB (270MBit/s)), 15dB (1.485 GBit/s)
Reference Manual D VD 3620 Version1.2 Available Options Below is a list of available options for the D VD 3620 MiniModule. Please refer to product brochures or our web site for more detailed information. Model Description External brick power supply module for R PS 3001 E Series 3000 MiniModules.
Reference Manual D VD 3620 Version1.2 Parts List Due to the very dense design and high level of integration there are no user serviceable electronic assemblies within the D VD 3620 module. D VD 3620 Mini Module (complete) Description HD/SD Dist Amp Dig Video...
Reference Manual D VD 3620 Version1.2 Contact Information Please contact your local distributor; this is your local and fastest method for obtaining support and sales information. LYNX Technik can be contacted directly using the information below. Address LYNX Technik AG Brunnenweg 3 64331 Weiterstadt Germany.
Page 23
Reference Manual D VD 3620 Version1.2 This Page is intentionally left blank Page 23...