Reference Manual D VA 3120 L Version1.2

Electrical Installation.

Stand Alone Operation

The MiniModule requires the R PS 3001 power brick
option for stand-alone operation. Three versions are
available R PS 3001 E for European markets, R PS
3001 U for the US markets or the universal R PS 3001-
3 desk power supply. Please ensure you have the
correct power option for your region. The
connection to the module is made with a small 5-
pin connector, which has a twist bayonet securing
system. Please make sure the connection is solid
and locked in place. A strain relief is included within
the module to prevent excessive strain on the
connection.
Signal connections should be made with care,
please ensure connections are correct and
compatible equipment is feeding / receiving the
signals from the module or damage can result.
!
!
Page 14
Caution. Only use the optional Lynx R PS 1
power modules. Ensure the 5-pin power
connector is locked securely in place.
Caution. Care needs to be taken when
using the module in this way, if it is not
physically secured. Keep the module
away from the floor to avoid the risk of
someone stepping or tripping on the unit,
and locate the unit away from excessive
sources of heat and any sources or
moisture.