Lynx D VD 5830 Reference Manual

Triple 3gbit/s dual sdi/asi distribution amplifier

Advertisement

Quick Links

LYNXTechnik
AG
®
Broadcast Television Equipment

Reference Manual

D VD 5830
Triple 3GBit/s Dual SDI/ASI Distribution Amplifier
Revision 1.0
April 2012
This Manual Supports Device Revisions:
D VD 5830 Firmware Revision
494
Control System GUI Release
6.0.0
Information in this document is subject to change without notice. No part of this document may be reproduced or
transmitted in any form or by any means, electronic or mechanical for any purpose, without express written permission of
LYNX Technik AG.
LYNX Technik AG may have patents, patent applications, trademarks, copyrights or other intellectual property rights
covering the subject matter in this document. Except as expressly written by LYNX Technik AG, the furnishing of this
document does not give you any license to patents, trademarks, copyrights or other intellectual property of LYNX Technik
AG or any of its affiliates.
LYNX Technik AG
Brunnenweg 3
D 64331 Weiterstadt
Germany
www.lynx-technik.com
© 2012 LYNX Technik AG all rights reserved

Advertisement

Table of Contents
loading

Summary of Contents for Lynx D VD 5830

  • Page 1: Reference Manual

    LYNX Technik AG may have patents, patent applications, trademarks, copyrights or other intellectual property rights covering the subject matter in this document. Except as expressly written by LYNX Technik AG, the furnishing of this document does not give you any license to patents, trademarks, copyrights or other intellectual property of LYNX Technik AG or any of its affiliates.
  • Page 2: Table Of Contents

    D VD 5830 Reference Manual. Rev 1.0 Contents CONTENTS ........................2 WARRANTY ........................3 REGULATORY INFORMATION ..................4 ........................... 4 UROPE USA ..........................4 GETTING STARTED ......................5 ........................5 ACKAGING ESD W ......................... 5 ARNING Preventing ESD Damage .................... 5 PRODUCT DESCRIPTION ....................
  • Page 3: Warranty

    LYNX Technik supplies; or d) to service a product which has been modified or integrated with other products when the effect of such modification or integration increases the time or difficulty servicing the product.
  • Page 4: Regulatory Information

    D VD 5830 Reference Manual. Rev 1.0 Regulatory information Europe Declaration of Conformity LYNX Technik AG Brunnenweg 3 D-64331 Weiterstadt Germany Declare under our sole responsibility that the product TYPE: D VD 5830 To which this declaration relates is in conformity with the following...
  • Page 5: Getting Started

    D VD 5830 Reference Manual. Rev 1.0 Getting Started Most CardModules are installed into the rack frames and system tested in the factory. If this is an upgrade part, or service exchange item then the module is supplied in a padded cardboard carton which includes the CardModule, rear connection plate and mounting screws.
  • Page 6: Product Description

    The D VD 5830 is a high quality triple channel 3GBit/s / HD / SD SDI/ASI distribution amplifier designed primarily for broadcast and professional applications. Flexible configurations allow the D VD 5830 to be used in dual 1 to 4 applications or 1 to 8 applications. Inputs can be reclocked, or non-reclocked. Auto detection of multirate digital video bit rates in reclocked mode (143Mbit/s, 177Mbit/s, 270Mbit/s, 360Mbit/s, 1.485 GBit/s, 2.985GBit/s) and will transparently pass data from 15 Mbits/s to 2.985 GBit...
  • Page 7: Module Layout

    D VD 5830 Reference Manual. Rev 1.0 Module Layout Module Front Termination Panel CardModule Page 7 of 17...
  • Page 8: Connections

    Connections Video The D VD 5830 uses standard 75 Ohm BNC connectors. We recommend the use of high quality video cable for digital video connections to reduce the risk of errors due to excessive cable attenuation. Max cable lengths the module will support are shown below.
  • Page 9: Settings And Control

    D VD 5830 Reference Manual. Rev 1.0 Settings and Control The D VD 5830 has an integrated micro-controller, which enables the module to be configured and controlled locally via the dip-switch or from remote when using one of the optional controllers and control software.
  • Page 10: Switch Settings

    D VD 5830 Reference Manual. Rev 1.0 Switch Settings Below the switch settings for the 8-position dip-switch are defined. Swit Setting Function Enable Local Adjustment Disable Local Adjustment Output 1 reclocked Output 1 non-reclocked Output 2 reclocked Output 2 non-reclocked...
  • Page 11: Factory Preset Condition

    D VD 5830 Reference Manual. Rev 1.0 Factory Preset Condition The D VD 5830 is delivered programmed and preset for the following mode of operation: Switch 1 Local Adjustment Enabled Switch 2 -4 reclocked Switch 8 FAST If this is the mode of operation required, then no adjustments are necessary.
  • Page 12: Alarm/Led Status Indicators

    D VD 5830 Reference Manual. Rev 1.0 Alarm/LED Status Indicators The D VD 5830 module has integral LED indicators, which serve as alarm and status indication for the module. Function is described below. Channel Condition Indicators LED 1, 2 and 3...
  • Page 13: Control System Gui

    D VD 5830 Reference Manual. Rev 1.0 Control System GUI When using the module in a system with the optional LYNX control system all module settings are available on an intuitive Windows GUI interface. Any settings made using the control system will override any settings made locally. All settings are stored automatically in the module flash RAM.
  • Page 14: Main Tab

    D VD 5830 Reference Manual. Rev 1.0 Main Tab This screen is the main interface and is presented first when the module is displayed in the GUI. The input detection indicates the bit rate of a connected signal. If no signal is detected the color of the input detection will turn red.
  • Page 15: Events Tab

    (This has no impact or influence over the internally error log maintained by the LYNX control system) (Internal LYNX error logging and external SNMP traps can be configured independently). Note. The simulated event is part of the GUI simulator and allows us to force a particular error condition for testing and demonstration purposes.
  • Page 16: Specifications

    < 0.3 UI (Alignment Jitter); < 3.0 UI (Timing Jitter); (2.97GHz) Return Loss > 15 dB (1.5GBit/s) Control Local Controls Dip Switch Remote Control Comprehensive remote control and status monitoring supported when used with a LYNX Controller option Electrical Specifications Voltage 12 VDC Power <5 W...
  • Page 17: Service

    Technical support is also available from our website. Please do not return products to LYNX without an RMA. Please contact your authorized dealer or reseller for more details. More detailed product information and product updates may be available on our web site: www.lynx-technik.com...

Table of Contents