Special Conditions for Safe Use (X):
1. The Rosemount 3051 Wireless Pressure Transmitter shall only be used with the
701PGNKF Rosemount SmartPower
2. The in-line pressure sensor may contain more than 10% aluminum and is considered a
potential risk of ignition by impact or friction. Care must be taken into account during
installation and used to prevent impact and friction.
3. The surface resistivity of the transmitter housing is greater than 1 GΩ. To avoid
electrostatic charge build-up, it must not be rubbed or cleaned with solvents or a dry
cloth.
Range 6
Certificate: CSA 2526009
Standards: FM Class 3600 - 2011, FM Class 3610 - 2010, FM Class 3810 - 2005, ANSI/ISA
Markings: IS CL I, DIV 1, GP A, B, C, D T4; CL 1, Zone 0 AEx ia IIC T4;
4.7
Canada
I6 Canada Intrinsically Safe
Certificate: CSA 2526009
Standards: CAN/CSA C22.2 No. 0-M91, CAN/CSA C22.2 No. 94-M91,
Markings: Intrinsically Safe for Class I, Division 1, Groups A, B, C, D, T4 when installed per
4.8
Europe
I1 ATEX Intrinsic Safety
Certificate: Baseefa12ATEX0228X
Standards: EN 60079-0:2012, EN 60079-11:2012
Markings:
Special Conditions for Safe Use (X):
1. The plastic enclosure may constitute a potential electrostatic ignition risk and must
not be rubbed or cleaned with a dry cloth.
2. The Model 701PGNKF Power Module may be replaced in a hazardous area. The power
module has a surface resistivity greater than 1 GΩ and must be properly installed in
the wireless device enclosure. Care must be taken during transportation to and from
the point of installation to prevent electrostatic charge build-up.
4.9
International
I7 IECEx Intrinsic Safety
Certificate: IECEx BAS 12.0124X
Standards: IEC 60079-0:2011, IEC 60079-11:2011
Markings: Ex ia IIC T4 Ga, T4(–40 °C ≤ T
60079-0 - 2009, ANSI/ISA 60079-11 - 2009, UL 61010-1 (3rd edition), UL50E
(1st Edition)
T4(–40 °C ≤ T
≤ +70 °C) when installed per Rosemount drawing 03031-1063;
a
Type 4X/IP66/IP68
CSA Std C22.2 No. 142-M1987, CSA Std C22.2 No. 157-92,
CSA Std C22.2 No. 60529:05
Rosemount drawing 03031-1063; Type 4X/IP66/IP68
II 1 G Ex ia IIC T4 Ga, T4(–40 °C ≤ T
Battery Pack.
≤ +70 °C); IP66/IP68
a
≤ +70 °C); IP66/IP68
a