Product Specific Safety Rules

WARNING
 This product is for domestic use.
This unit complies with the domestic safety standards only. The product cannot be used overseas.
 When using an extension cord, select the wire diameter according to the extended length.
If the power cord is too long or a thin cable is wound on a coil drum for a long length, voltage drop could be
caused. In such a case, the original product performance cannot be demonstrated.
 Do not use the product together with another electric tool.
CAUTION
 This tool is not an impact type electric screwdriver. Do not tighten twice (extra tightening). Also, it cannot be
used for screw tightening of such things as wood or drywall.
Depending on fastening conditions, screws may become loose.
Improper impacts could decrease product life or cause product failure.
 Do not use the tool for anything other than screw tightening.
It should not be used for tasks such as drilling or threading (such as a tapper).
 Install the power cord and signal line separated from each other.
If AC line noise directly propagates to the signal line, poor contact of ASLINK may occur. If the product is used as
in the shipped status (1 m portion is in a collected state), it is no problem.
About Unit Notation
This instruction manual is written using both SI units and the imperial measurement method (yards, pounds).
Numeric values outside the ( ) are the value in SI units, while those inside the ( ) are the imperial measurement
value.
Notation Example: Length 25.4 (1")
Maximum extended cable length
10 m
20 m
30 m
Weight: 0.45 (1)
in
mm
Wire diameter
(conductor nominal cross-sectional area)
1.25 mm
or more
2
2 mm
or more
2
3.5 mm
or more
2
Torque: 1.13 (10)
lbs
kg
EN
Lb·in
Nm
1