4 INSTALLATION
4
INSTALLATION
The installation must be carried out by a professional.
NOTE!
Connect the power source to the electricity mains with a network impedance of
0.268 (C250 3ph) ohm or lower. If the network impedance is higher, there is a risk of
flicker in the illuminators.
CAUTION!
This product is intended for industrial use. In a domestic environment this product
may cause radio interference. It is the user's responsibility to take adequate
precautions.
4.1
Location
Position the welding power source in such way that its cooling air inlets and outlets are not
obstructed.
4.2
Assembly of components
WARNING!
For packing and shipment of the power source the wheels are detached from
the unit.
Before use attach the wheels according to instruction.
0463 344 101
- 9 -
© ESAB AB 2022