9.
Set "Network Configuration Settings" in the "CC-Link IE TSN Configuration" window.
[Navigation window] [Parameter] [Module Information] [RJ71GN11-SX] [Basic Settings] [Network
Configuration Settings]
10.
Click the [Close with Reflecting the Setting] button to close the "CC-Link IE TSN Configuration" window.
11.
Set "Refresh Settings" as follows.
[Navigation window] [Parameter] [Module Information] [RJ71GN11-SX] [Basic Settings] [Refresh Setting]
12.
Click the [Apply] button.
13.
Write the set parameters to the CPU module on the master station. Then, reset the CPU module or power off and on the
system.
[Online] [Write to PLC]
In this example, default values are used for parameters that are not shown above. For the parameters, refer to
the following.
MELSEC iQ-R CC-Link IE TSN User's Manual (Application)
8 COMMUNICATION EXAMPLES
8.2 RJ71GN11-SX Communication Example
8
93