Chapter 8 Communication Examples; Rj71Gn11-T2 Communication Example; System Configuration; Link Device Assignment - Mitsubishi Electric MELSEC iQ-R Series User Manual

Cc-link ie tsn
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

8
COMMUNICATION EXAMPLES
8.1

RJ71GN11-T2 Communication Example

The following shows an example of a cyclic transmission program using the RJ71GN11-T2 master station and local station.

System configuration

• Power supply module: R61P
• CPU module: R04CPU
• Master/local module: RJ71GN11-T2 (start I/O number: 0000H to 001FH)
No.0
No.0: Master station (station No.0)
No.1: Local station (station No.1)
No.2: Local station (station No.2)

Link device assignment

For RX, RY, RWr, and RWw, 256 points are assigned to each station.
For LB and LW, 512 points are assigned to each station.
Unicast mode
■RX/RY assignment
Each of the following No.0 to No.2 represents a station number.
No.0 is master station, and No.1 and No.2 are local stations.
R04CPU
X
1000H
No.1
10FFH
1100H
No.2
11FFH
Y
1000H
→No.1
10FFH
1100H
→No.2
11FFH
No.1, No.2: Send range to station No.1, send range to station No.2
No.1, No.2: Send range from station No.1, send range from station No.2
8 COMMUNICATION EXAMPLES
70
8.1 RJ71GN11-T2 Communication Example
No.1
No.0
RX
0000H
No.1
00FFH
0100H
No.2
01FFH
RY
0000H
→No.1
00FFH
0100H
→No.2
01FFH
No.2
No.1
RX
0000H
No.1
00FFH
0100H
01FFH
RY
0000H
←No.1
00FFH
0100H
01FFH
No.2
R04CPU
X
RX
0000H
00FFH
0100H
No.2
No.2
01FFH
RY
Y
0000H
00FFH
0100H
←No.2
←No.2
01FFH
1000H
10FFH
1100H
11FFH
1000H
10FFH
1100H
11FFH

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rj71gn11-t2Rj71gn11-sx

Table of Contents