Command
ipv4.address(static)="10.15.0.220"
[CR]
reset(user) [CR]
reset(user) [CR]
aspect? [CR]
aspect# [CR]
aspect=fill [CR]
aspect=3 [CR]
brightness @@ [CR]
fake.command = 1 [CR]
brightness(zone.999) = 100 [CR]
brightness="new value" [CR]
model.id = 1 [CR]
display.name = "Name containing \"
and \\"
power.on.delay = .1
Planar UltraRes P Series RS232 User Manual
020-1408-02A
8
Response
IPV4.ADDRESS(STATIC)="10.15.0.
220" [CR]
RESET(USER)@ACK [CR]
RESET(USER)^NAK [CR]
ASPECT:AUTO [CR]
ASPECT:0 [CR]
ASPECT:FILL [CR]
ASPECT:3 [CR]
BRIGHTNESS!ERR 1 [CR]
FAKE.COMMAND:ERR 3 [CR]
BRIGHTNESS(ZONE.999)!ERR 4
[CR]
BRIGHTNESS!ERR 5 [CR]
MODEL.ID!ERR 6 [CR]
DISPLAY.NAME:"Name containing \"
and \\"
POWER.ON.DELAY:0.1
Notes
Example command with a string
operator
Example action command (no
operator or operand)
Example action command that
cannot be processed at this time
The name for the Aspect Ratio
setting value is returned
The number for the Aspect Ratio
setting value is returned
Sets the Aspect Ratio to Fill
Also sets the Aspect Ratio to Fill
Example of an invalid syntax ("@@"
isn't a valid operator)
Example of an invalid opcode
("FAKE.COMMAND" doesn't exist)
Example of an invalid modifier
("ZONE.999" isn't a valid modifier for
"BRIGHTNESS")
Example of an invalid operand (the
Brightness command doesn't accept
a string operand)
Example of an invalid operator
(cannot write to this command)
The name will appear on the remote
monitor as Name containing " and \
Example of a fixed point operand.
Sets the Power On Delay to 0.1
seconds.