Planar UltraRes URP98 User Manual page 45

Hide thumbs Also See for UltraRes URP98:
Table of Contents

Advertisement

Setting
Command Code
Subnet
IPV4.NETMASK
1205 =?
Mask
System
SYSTEM.STATE
2310 ?
State
Planar UltraRes P Series RS232 User Manual
020-1408-02A
45
Modifiers
0 = STATIC
String
[None = Current (for
reads only]
[None = STATIC (for
writes only]
0 = STANDBY
1 = POWERING.ON
2 = ON
3 = POWERING.
DOWN
4 = BACKLIGHT.OFF
5 = FAULT
Example
Yes
[Read the current subnet mask
value]
IPV4.NETMASK?
IPV4.NETMASK:"255.255.254.0"
[Write the subnet mask for static IP]
IPV4.NETMASK(STATIC)="255.255.
255.0"
IPV4.NETMASK(STATIC):"255.255.
255.0"
No
SYSTEM.STATE?
SYSTEM.STATE:STANDBY
Notes
See Main -> Advanced
Settings -> Network ->
Subnet Mask.
Indicates the current state
of the system:
- STANDBY: The system
is in its lowest power
mode. Not all functions
are available.
- POWERING.ON: The
system is transitioning
from the STANDBY state
to the ON state.
- ON: The system is on
with the backlight on.
- POWERING.DOWN:
The system is
transitioning from the ON
state to the STANDBY
state.
- FAULT: A system failure
has occurred. Use the
Error Log command to
get more information.
Operands FAULT and
BACKLIGHT.OFF
available only on URP75 /
URP85 / URP98.