Planar UltraRes URP98 User Manual page 46

Hide thumbs Also See for UltraRes URP98:
Table of Contents

Advertisement

Setting
Command Code
Test Email
NETWORK.
1229 !
SMTP.TEST
Test
PATTERN
1307 !
Pattern
Time
TIME
1100 =?
Planar UltraRes P Series RS232 User Manual
020-1408-02A
46
Modifiers
Event
0 = POWER.STATE.
CHANGED
1 = ERROR.
OCCURRED
2 = SOURCE.
DETECTED
3 = SOURCE.LOST
4 = SOURCE.
SELECTED
Pattern
0 = NONE
1 = BLACK
2 = WHITE
3 = GRAY
4 = RED
5 = GREEN
6 = BLUE
7 = CYAN
8 = MAGENTA
9 = YELLOW
11 = GRAYBAR
12 = REDBAR
13 = GREENBAR
14 = BLUEBAR
16 = CHECKER-
BOARD
18 = COLORBAR
0 = YEAR
Unsigned int
1 = MONTH
2 = DATE
3 = HOUR
4 = MINUTE
[None = ALL]
Example
Yes
NETWORK.SMTP.TEST(SOURCE.
LOST)
NETWORK.SMTP.TEST(SOURCE.
LOST)@ACK
No
PATTERN(GRAYBAR)
PATTERN(GRAYBAR)@ACK
Yes
[Set the month to March]
TIME(MONTH)=3
TIME(MONTH):3
Notes
See Remote Monitoring
Software -> Notifications
-> Test Email.
See Main -> Advanced
Settings -> Test Pattern.
CHECKERBOARD and
COLORBAR are available
only on URP75 / URP85 /
URP98.
See Main -> Advanced
Settings -> Schedule ->
Set Date and Time.
Page | 46