Skycoded Module; Skycoded Control Module (Cm1) - Skyjack SJ3219 Service Manual

Dc electric scissors
Hide thumbs Also See for SJ3219:
Table of Contents

Advertisement

Section 5 – Procedures
Skycoded Control Module Pin Chart
PIN
WIRE # AND
PLUG
#
COLOUR
B+
03B Black
B-
00 Black
M
M- Black
P1
1
08B Green
P1
2
59 Orange/Black
P1
3
00B White/Black
P1
4
19D White/Red
P1
5
CAN H
P1
6
CAN L
P1
7
Not Used
P1
8
60 Red/White
P1
9
29 Blue/Yellow
P2
1
Not Used
P2
2
28 Green/Red
P2
3
Not Used
60A Black/Red/
P2
4
Green
P2
5
28A Green/Red
P2
6
Not Used
P2
7
910 Black
P2
8
00C White
P2
9
22 Orange/Blue
P3
1
08C Purple/White
P3
2
08 Blue/White
P3
3
18 Red/Black
P3
4
120 Black
P3
5
10 Blue/White
P3
6
12 Blue
P3
7
09 Orange
P3
8
23 Black/White
P3
9
24 Blue/Black
P3
10
51A White
212508ADA
123
Lug for 24V supply voltage (from C1 Motor Contactor relay N.O. contact)
Lug for 0V reference from Battery negative (negative bus bar)
Lug for Output of Pulsed Negative (-) to initialize Pump Motor
Outputs and Analog Inputs
5V supply to Joystick PCB P8
0-5V Proportional Input from Joystick Analog PCB Output P7
0V reference to Joystick PCB P6
Input for Shutdown signal from Elevate Trackunit Telematics option (if equipped)
Communication CANbus High (if equipped)
Communication CANbus Low (if equipped)
Not Used
0V Reference Output (pulsed) for PL-1 Overload Light & PL-2 Overload Light
0V Reference Output (pulsed) for BP-29 Beeper for All-Motion, Tilt and Overload
Connects to Sensors
Not Used
0-5V Proportional Input from AT1 Angle Transducer Analog Output signal
(3.7 Volts when stowed)
Not Used
0-5V Proportional Input from PT1 Pressure Transducer Analog Output signal
0-5V Proportional Input from AT1 Angle Transducer Analog Output signal
(3.7 Volts when stowed)
Not Used
Output supply 24V (B+) for AT1, PT1 Transducers, Pothole Protection Limit switches
LS1, LS2, and Beeper BP-29
0V Reference Output to Holding Solenoids (2H-13-1 & 2H-13-2)
0V Reference Output (pulsed) to FL-22 Flashing Light
Platform Controls
24V Input from S10 Idle/PLTF/Base Key Switch for Platform and/or Base signal
** required input for any movement **
24V Input B+ Valve supply IF BOTH Emergency Stops are energized
(supplies all valve outputs) ** required input for any movement from Platform **
24V Input from S27 Torque Switch for High Torque signal
24V Input from S17 Indoor Select switch for Indoor signal (if equipped)
24V Input from S10 Idle/PLFT/Base Key Switch for Base signal
24V Input from S3 Lift/Off/Drive Switch for Drive signal
24V Input from S3 Lift/Off/Drive Switch for Lift signal
24V Input from S7-2 Joystick PCB P3 Steer Right signal
24V Input from S7-3 Joystick PCB P1 Steer Left signal
(KC built machines only) 24V Input from Anti-Overrising Limit switches N.O. contacts
PIN OUT

Skycoded Module

SJ3215, SJ3219

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sj3215

Table of Contents