Section 1 – Scheduled Maintenance
1.8 Platform inspection
WARNING
Fall Hazard. Use the three points of contact
principle when you use the MEWP to enter or exit
the platform. If you do not obey, there is a risk of
death or serious injury.
1. Enter the platform and close the gate.
Railings and gate
1
Make sure there are no loose or missing parts,
▪
and there is no visible damage.
Make sure that the lock-pins and fasteners are
▪
correctly locked.
Make sure that the platform railings are in the
▪
correct position and locked with lock-pins.
Make sure that the gate is in good condition and
▪
operates correctly.
Refer to
5.2-3 Railing Maintenance and Repair
▪
the railing maintenance information.
Fall-protection anchorages
2
Make sure that the fall-protection anchorages are
▪
correctly installed.
Make sure there is no visible damage.
▪
212508ADA
26
5
2
6
(B)
(B)
4
3
AC power socket
3
Make sure there is no visible damage.
▪
Platform control console
4
Make sure that the control console is locked with
▪
lock-pins.
Make sure that the platform control cable is
▪
correctly locked, and there is no visible damage.
Make sure all the switches operate correctly.
▪
Manual storage box
5
Make sure that the operation manual and other
▪
important documents are in the manual storage
box.
Make sure that the documents are in good
▪
condition, and you can read them.
Always put the manuals and other documents
▪
back in the storage box after use.
Extension platform
6
Make sure that the extension platform is correctly
▪
for
installed.
Make sure there is no visible damage or missing
▪
components.
Make sure the lock-pins are correctly attached.
▪
2. Use the MEWP ladder to exit the platform.
Platform inspection
1
2
(B)
(B)
(B)
(B)
SJ3215, SJ3219