Access Levels Procedure; Calibrate Level Procedure - Skyjack SJ3219 Service Manual

Dc electric scissors
Hide thumbs Also See for SJ3219:
Table of Contents

Advertisement

Section 5 – Procedures
5.4-8 Calibrate Load Procedure
The Control Module CM1 needs calibration before it
can calculate the platform load.
NOTE
This procedure is completed during factory build
of the machine and ONLY needs to be performed
if the Control Module CM1 is replaced.
IMPORTANT
Any changes to the machine mechanics,
hydraulics, etc. may require re-calibration!
Calibration of the MEWP automatically stops and
starts the platform at various points and records the
lift cylinder pressure and scissor angles at various
platform heights to enable load sense:
A. LOADED calibration – fully loaded platform
raised & lowered with stops to take
measurements.
B. EMPTY calibration – unloaded platform raised
& lowered with stops to take measurements.
The following procedure must be followed
COMPLETELY to calibrate the Control Module CM1;
throughout the procedure various checks are made
– if any problem is detected the procedure stops and
displays a FLASHING failure message listed at the end
of this procedure.
NOTE
If the calibration procedure is interrupted, completed
phases need not be repeated. A "REDO" prompt will
appear – answer "NO" if there is no reason to repeat
the phase, or "YES" if the phase must be repeated (for
example, a significant mechanical or hydraulic change
has been made).
Calibration Load Procedure
1. Make sure the MEWP is parked on level ground
and Level Calibration is performed (see
Calibrate Level
Procedure).
2. Enter the "ACCESS LEVEL " 2 code to enable
adjustments and calibrations (see
Levels
Procedure).
3. Press
or
to get to "LOAD SETUPS" and
press ENTER to select.
4. Press ENTER to run the "CALIBRATE LOAD"
option.
212508ADA
149
5. Make sure the MEWP is in base mode on the S10
NOTE
6. The display will show "PLATFORM DOWN?",
A. Press the ENTER button to confirm.
7. The display will show "PLATFORM LOADED?",
A. Toggle between LOADED and EMPTY with the
B. If rated load is available, add the rated load on
C. If no load is on the platform, make sure the
8. The display will show "PLEASE LIFT ...", waiting
A. Close the UP switch and keep it closed until
9. When the system detects the UP switch closed,
10. After a delay, the system will automatically
A. When the measurements have been taken, the
NOTE
5.4-7
5.4-6 Access
11. 1The lifting ... stopping ... measuring ... lifting
12. When the platform reaches full height (and height
base key switch by holding the momentary switch
to base.
Continue to hold the switch or the calibration
will have to be aborted and repeated from the
beginning!
asking for confirmation that the platform is stowed
all the way down.
asking for confirmation that the platform is loaded.
and
buttons.
the platform then press the ENTER button to
confirm that calibration is done LOADED.
platform is empty then press the ENTER button
to confirm that calibration is done EMPTY.
for the UP switch to be activated to begin raising
the platform.
the platform has reached full height.
the display will show "LIFT LOADED" with the
current height (from 0% to 100%).
stop the platform lift and take height &
pressure measurements; the display will show
"MEASURING #xx".
platform will resume lifting.
Continue to hold the switch or the calibration
will have to be aborted and repeated from the
beginning!
process will continue automatically until the
platform reaches full height.
100% is displayed), release the UP switch.
Skycoded Module
SJ3215, SJ3219

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sj3215

Table of Contents