Sole Diesel 165 GT Operator's Manual
Sole Diesel 165 GT Operator's Manual

Sole Diesel 165 GT Operator's Manual

Marine generator sets
Table of Contents

Advertisement

Quick Links

Introduction
Marine
generator sets
Electronic operation
Operator's manual
85 GT/GTC
100 GTA/GTAC
115 GT/GTC
120 GTA/ GTAC
165 GT/GTC
180 GTA/GTAC
U_CTGR109280E_EN
Revision 1
Solé, S.A. C-243 b, km 2 · 08760 Martorell (Barcelona) ·Tel. +34 93 775 14 00 · www.soleDiesel.com · info@soleDiesel.com
Operator's Manual Marine Diesel Gensets
2

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 165 GT and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Sole Diesel 165 GT

  • Page 1 Operator’s manual 85 GT/GTC 100 GTA/GTAC 115 GT/GTC 120 GTA/ GTAC 165 GT/GTC 180 GTA/GTAC U_CTGR109280E_EN Revision 1 Solé, S.A. C-243 b, km 2 · 08760 Martorell (Barcelona) ·Tel. +34 93 775 14 00 · www.soleDiesel.com · info@soleDiesel.com Operator’s Manual Marine Diesel Gensets...
  • Page 3: Introduction

    Introduction Introduction Presentation Dear Customer, First, we would like to thank you for choosing a Solé Diesel product. We recommend that you read this manual carefully before carrying out any of the operations and keep it close at hand, near the genset, as it can be of great use in the future.
  • Page 4: Table Of Contents

    Table of contents Table of contents Introduction ............................2 Table of contents ..........................3 Safety precautions and instructions ..................... 6 Solé Diesel warranty ..........................9 Section 1 – Genset Information ......................12 1.1. Genset Identification....................... 12 1.2. Genset parts identification ..................... 13 Section 2 –...
  • Page 5 Table of contents 5.5. Fuel System ..........................27 Circuit description ..........................27 Fuel specifications ..........................27 Maintenance task. Fuel level inspection..................27 Maintenance task. Fuel tank clean ....................27 Maintenance task. Water separator filter purge ................28 Maintenance task. Fuel filter change ....................28 Maintenance task.
  • Page 6 Table of contents Maintenance task. Cleaning and lubrication .................. 40 Section 6 – Troubleshooting ......................41 Section 7 – Alarms list (ECU) ......................47 7.1. Malfunction indicator lamp ......................47 7.2. Diagnostic button and malfunction indicator lamp ..............48 Section 8 – Parallel operation ......................53 Section 9 –...
  • Page 7: Safety Precautions And Instructions

    Safety precautions and instructions Safety precautions and instructions Solé Diesel is concerned for your safety and your machine’s condition. Safety Precautions and Instructions are one of the primary ways to call your attention to the potential hazards associated with our engine operation. Follow the precautions listed throughout the manual before and during operation and maintenance procedures for your safety, the safety of others and the performance of your engine.
  • Page 8 Safety precautions and instructions Carbon monoxide (CO) can cause severe nausea, fainting or death. Engine exhaust gases contains carbon monoxide gas. Carbon monoxide is an odourless, colourless, tasteless, no irritating gas that can cause death if inhaled for even a short time. Get fresh air and do not sit, lie down or fall asleep if anyone shows signs of carbon monoxide poisoning: - Light-headedness, dizziness - Physical fatigue, weakness in joints and muscles.
  • Page 9 Safety precautions and instructions 2. The installer / operator of the engine has to wear personal protective equipment such as gloves, work shoes, eye and hearing protection as required by the task. 3. The area in which the operator is working has to be kept tidy and free of oil and other liquid spillages and solid waste (metal chips, etc.).
  • Page 10: Solé Diesel Warranty

    Sole Diesel Warranty Solé Diesel warranty Read the manual and documents delivered with each engine before carrying out any of the operations or presenting any queries. The engine is supplied without any liquids. Ensure that the liquids used match the specifications contained in Solé Diesel manuals.
  • Page 11 Sole Diesel Warranty b) The warranty covers any failure of the product under normal opera- ting conditions caused by a defect in manufacturing. c) The warranty covers the labour costs necessary to replace and/or repair the defective original components, according to Solé Diesel standards of excellence. The time period covered for these operations is limited to 4 hours.
  • Page 12 Sole Diesel Warranty The obligations of Solé Diesel are restricted to repairing the defective parts or, IF DEEMED APPROPRIATE BY Solé Diesel, returning the amount of the purchase, or replacing the parts to prevent poor operation resulting from defective materials or faults in the manufacture covered by the warranty.
  • Page 13: Section 1 - Genset Information

    Genset information Section 1 – Genset Information 1.1. Genset Identification Identification label The nameplate is located above the rocker cover. The characteristics plate of genset it’s located above the alternator case. The characteristics plate of canopy genset it’s located outside, as shown in the following picture: Genset serial number: In addition, all gensets are marked with the serial number on the block, on the fuel injection pump.
  • Page 14: Genset Parts Identification

    Genset information 1.2. Genset parts identification Gensets: 85 GTC / 100 GTAC / 115 GTC / 120 GTAC / 165 GTC / 180 GTAC PART ELEMENT Fuel filter Oil filter Oil fill cap Expansion tank Dipstick Intercooler assy ¹ DC alternator Injectors Belt protection case Starter assy...
  • Page 15: Section 2 - Transport, Handling And Storage

    Transport, handling and storage Section 2 – Transport, Handling and Storage 2.1. Reception When the genset is delivered make sure that the packing has not been damaged during transport and that it has not been tampered with or that components inside the packing have been removed (see information marked on covers, bases and cartons).
  • Page 16: Transporting And Handling The Unpacked Genset

    Transport, handling and storage 2.3. Transporting and Handling the Unpacked Genset When the genset is unpacked and ready for transport, use EXCLUSIVELY the appropriate lifting eyebolts. For 85 GTC / 100 GTAC / 115 GTC / 120 GTAC models: For 165 GTC / 180 GTAC models: DETALLE C DETALLE A DETALLE B...
  • Page 17: Section 3 - Installation

    Installation Section 3 – Installation 3.1. Angle of Installation Make sure the genset is installed on a level surface. Otherwise, the following angular operation maximum is permitted: Continuously Temporary 85 GTC / 100 GTAC 10º 30º (Max. 30 min.) 115 GTC / 120 GTAC 10º...
  • Page 18: Section 4 - Operation

    Operation Section 4 – Operation 4.1. Prestart checklist Follow these checks and inspections to ensure the correct genset operation. In addition, some checks require verification after unit starts. AIR CLEANER: Check for a clean and installed air cleaner element to prevent unfiltered air from entering the genset.
  • Page 19: Winterzation And Preservation

    Operation 3. Use oil with suitable quality and viscosity. SAE 15W40 is recommended. Under extreme conditions contact with technical support. 4. Cover battery with an adequate material to protect it against the cold. Check that the battery is fully charged. It is also advisable to use a dielectric spray on the electrical connections.
  • Page 20: Maintenance During The Storage

    Operation 4.4. Maintenance during the storage During the long genset storage, it must be stored inside a ventilated area and free of humidity. When the genset stay stopped for 3 months or more, inside parts can be oxidize and lost the oil film.
  • Page 21: Section 5 - Systems And Scheduled Maintenance

    Systems and scheduled maintenance Section 5 – Systems and Scheduled Maintenance 5.1. Operating Description Information of special tools required and basic safety precautions. Disassembly: ✓ Use the correct tools and instruments. Serious injury or damage to the genset can result from using the wrong tools and instruments.
  • Page 22 Systems and scheduled maintenance Intervals Every Every Every Every 2 Winter storage and Inspection Item Daily 1st 20h-50h Every year 200h 400h 800h years Preservation Screw tightening, fastening. Engine block. General Valve clearance. Exhaust gas, noise and vibrations. Compression pressure. Lubrication Genset oil.
  • Page 23: General

    Exhaust 0,5 mm Inspection (without pressure washer) Do these operations in an authorised Sole Diesel Service. Before adjusting valve clareance, allow the engine to cool for at least 30 minuts. The oil temperature should be below 80ºC. 1. Loosen ventilation valve and swing it to the side.
  • Page 24 1. Loosen ventilation valve and swing it to the side. 2. Remove the cylinder head cover. 3. Do these operations in an authorised Sole Diesel Service. Before adjusting valve clareance, allow the engine to cool for at least 30 minuts. The oil temperature should be below 80ºC.
  • Page 25: Maintenance Task. Compression Pressure Inspection

    Systems and scheduled maintenance Maintenance task. Compression pressure inspection Start by: 1. Make sure the genset oil level, air cleaner, starting motor and battery are well-conditioned. 2. Start the genset and allow it to warm up thoroughly, until 50ºC or more coolant temperature. Measure the compression pressure on all cylinders: 1.
  • Page 26: Lubrication System

    Systems and scheduled maintenance 5.4. Lubrication System Circuit description The lubrication circuit is forced by the trochoid gear pump, and it is composed of the following elements. PIECE ELEMENT Oil pan Scroop Oil pump Valve, flow control Valve, máximum pressure Engine oil cooler Oil filter Oil pipe...
  • Page 27: Maintenance Task. Oil Level Check

    (L). The check should be done by taking the measurement from the lower end of the dipstick. 85 GTC / 100 C/ 115 GTC / 120 Inclination GTAC / 165 GT /180 GTAC Min. (L) Max. (H) H: oil dipstick maximum level.
  • Page 28: Fuel System

    Systems and scheduled maintenance 5.5. Fuel System Circuit description The fuel system is based on a fuel feed pump and an in-line mechanical injection pump. PIECE ELEMENT Circuit compensation valve Return fuel tube Nozzle Injection pump Fuel pump Fuel filter Fuel hose Fuel filter (water separator) Valve...
  • Page 29: Maintenance Task. Water Separator Filter Purge

    Systems and scheduled maintenance Maintenance task. Water separator filter purge The fuel system must have a water separator filter (supplied as accessory) to avoid the inlet of water in the fuel circuit. According to the maintenance plan it is necessary to purge the filter to eliminate water periodically.
  • Page 30: Cooling System

    Systems and scheduled maintenance For this operation you must follow these steps: 1. Loosen all injection pipes. 2. Start the engine to blow air into the injection lines and injectors automatically. 3. When the fuel overflows from one injection pipe, tighten it and wait for the fuel to come out of another.
  • Page 31: Coolant Specifications

    Systems and scheduled maintenance Coolant specifications It is recommended use Solé Diesel 50% coolant or another coolant with similar specifications. On the other hand, distilled water with an anti-freezing agent is also suitable. The anti-freezing agent concentration according to operating conditions is specified in anti-freezing agent package labels. It is advisable select the anti-freezing agent concentration based on a temperature approx.
  • Page 32: Maintenance Task. Seawater Pump Impeller Inspection

    Systems and scheduled maintenance Maintenance task. Seawater pump impeller inspection Seawater pump impeller is neoprene and cannot rotate dried. If operated without water, the impeller can be broken. It is important therefore that a spare impeller is always available. Impeller inspection and replacement procedure: 1.
  • Page 33: Inlet And Exhaust System

    Systems and scheduled maintenance 5.7. Inlet and Exhaust System Exhaust circuit description To 165 GTC / 180 GTAC models: These standard models are equipped with dry exhaust. There are 3 variants depending on the installation on your boat: - Dry exhaust adapter to join the pipe in the exhaust system of the boat. - Flexible exhaust.
  • Page 34: Maintenance Task. Air Filter Inspection

    Systems and scheduled maintenance Type 1 installation. When between water injection point of wet exhaust and waterline is minimum 150 mm. Type 2 installation. When between water injection point of wet exhaust and waterline there is less than 150 mm or the point of injection is below waterline. The wet exhaust is the genset’s standard equipment.
  • Page 35: Maintenance Task. Turbocharger Cleaning And Inspection

    Systems and scheduled maintenance Maintenance task. Turbocharger cleaning and inspection Turbocharger maintenance To extend turbocharger life and efficiency, some basically important are given below: Inspect for possible oil leaks in the inlet and outlet ducts, as well as inside the turbo. A lack of lubrication or the appearance of oily residue could lead to shaft seizure and premature seal wear.
  • Page 36: Electrical System

    Systems and scheduled maintenance 5.8. Electrical System Control panel 85 GTC / 100 GTAC / 115 GTC / 120 GTAC models: These models are supplied without control panel. It is necessary to purchase the appropriate power and control kit for each model. 165 GTC / 180 GTAC model: These genset models are supplied with the control panel.
  • Page 37 Systems and scheduled maintenance Function table Oil pressure sensor: Pressure Resistance Tolerance Operating voltage: 6-24V (BAR) (ohm) (ohm) Operating current: >20mA, <85mA, Pmax<0.25W +3/-5 Operating temperature: -20°C to +100°C ±4 Measuring range: 0 – 10 BAR ±4 Absolute max. value: 30 BAR, max. 2 seconds. ±5 Protection: BODY IP 67 ±5...
  • Page 38: Battery

    Systems and scheduled maintenance Battery The minimum recommended capacity is 100 Ah. However, this value serves as a general reference since it relates to the maximum intensity it can offer for starting the generator set. The connection of the battery for a standard engine: Battery capacity •...
  • Page 39: Maintenance Task. Starter Motor Inspection

    Systems and scheduled maintenance Maintenance task. Starter motor inspection 1. Check if there is any impurity in pinion teeth. 2. Make sure that the pinion shaft turns freely when turned in the direction of driving (clockwise) and it is locked when turned in the opposite direction.
  • Page 40: Maintenance Task. Battery Level

    Systems and scheduled maintenance the alternator belt pulley (1) to the right until the correct belt tensión. Tighten the screw (2). 2. When the belt is unfitted, check the condition of the pulley recesses, they shall be dry and clean. Its cleanliness is performed with soap water (never use petrol, gas oil or similar products).
  • Page 41: Maintenance Task. Control Bearings

    Systems and scheduled maintenance Maintenance task. Control bearings During maintenance control the condition of the bearing and check that no grease has leaked: the lifespan of the bearings depends on the vibrations and axial strains they undergo (vibrations can increase considerably with a bad alignment) and on the working conditions. So, check for any unusual signs: vibrations, unusual noises.
  • Page 42: Section 6 - Troubleshooting

    If a fault occurs in the genset, proceed as follows: ➢ Within the period of warranty: • Contact to Sole Diesel Official Service. See Solé Diesel WARRANTY. ➢ Outside the period of warranty: • Contact to Sole Diesel Official Service. See Solé Diesel WARRANTY.
  • Page 43 Troubleshooting GENSET FAILURE SYSTEM PROBABLE CAUSES RECOMMENDED ACTIONS Replace the fuse in the installation. If fuse blows again, check Power cable fuse (red). electrical system for overloads or short circuits. Discharged or empty battery. Charge the battery or replace it with a new one. ELECTRICAL SYSTEM Loose or corroded battery connections.
  • Page 44 Troubleshooting GENSET FAILURE SYSTEM PROBABLE CAUSES RECOMMENDED ACTIONS GENERAL The fuel regulator is not operational. Contact an Official Solé Diesel Service. Faulty or clogged fuel pump Check fuel pump inlet. Clogged fuel filter Replace fuel filter. FUEL SYSTEM Air in fuel system Bleed fuel system.
  • Page 45 Troubleshooting GENSET FAILURE SYSTEM PROBABLE CAUSES RECOMMENDED ACTIONS Strangled oil pressure-relief valve Clean the valve and check its operation. OIL PRESSURE TOO Faulty oil pressure valve Contact an Official Solé Diesel Service. LUBRICATION SYSTEM HIGH. Oil level too high. Reset oil level. Obstruction of oil lines.
  • Page 46 Troubleshooting GENSET FAILURE SYSTEM PROBABLE CAUSES RECOMMENDED ACTIONS Faulty coolant water pump. Check coolant pump (impeller, pump sealing). Clean the tap, check if the salt water pump impeller is Plugged or restricted-pitch salt water tap. damaged. Faulty salt water pump. Check sea water pump (impeller, pump sealing).
  • Page 47 Troubleshooting GENSET FAILURE SYSTEM PROBABLE CAUSES RECOMMENDED ACTIONS CA open output breaker. Close the CA output breaker. Open wiring, terminals or exciter field pin. Check continuity. The main field (rotor) is not operational (open or Test and/or replace alternator assembly. earthed).
  • Page 48: Section 7 - Alarms List (Ecu)

    Alarm List (ECU) Section 7 – Alarms list (ECU) There are four ways to diagnose any failure or malfunction in the generator set: • Malfunction indicator lamp. • Diagnostic button and malfunction indicator lamp. • List of ECU alarms on the control panel. •...
  • Page 49: 7.2. Diagnostic Button And Malfunction Indicator Lamp

    Alarm List (ECU) Control function for configured warning lamps Warning lamp also switches on during the self-diagnosis (2 s) when ECU is activated (key switch (pin 15)). 7.2. Diagnostic button and malfunction indicator lamp It is possible to read existing failures using the indicator light and delete them from the failure memory using the diagnostic button.
  • Page 50 Alarm List (ECU) Hereunder you will find the steps to carry out the reading of the failure code issued by the lamp: a) The indicator lamp shows a failure. Example: Continuous flashing light. Press diagnostic button 1 to 3 seconds. Flashing or continuous indicator lamp light will switch off.
  • Page 51 Alarm List (ECU) CODE FAULT FAULT GROUP DESCRIPTION Short Long Short CAUSE REMARKS HELP 0.4 s 0.8 s 0.4 s Zero error display No faults 524287 ECU in emergency operation (if sensor 2 is available). Speed sensor 1 Emergency switch-off (if sensor Sensor failure Gear 2 is not available or failed).
  • Page 52 Alarm List (ECU) Coolant temperature sensor Value has exceeded Check coolant level. Check sensor switch-off switch-off limit. temperature and wiring. Value below switch-off Air temperature sensor switch-off Check sensor and wiring. limit. Low coolant level switch Emergency stop button. Start Check coolant level.
  • Page 53 Alarm List (ECU) Check CAN connection and connecting Broken wire, short circuit or BUS SID 231 cable. Check sensor and replace if error. required. Parameter Parameter Programming (EPROM SID 253 programming fault in Writing) governor fixed memory. Turn the ignition off and on again. Constant monitoring of Check again.
  • Page 54: Section 8 - Parallel Operation

    Parallel operation Section 8 – Parallel operation This generator set can be operated with or without the Parallel Kit supplied by Solé Diesel. Refer to the Parallel Kit Manual to operate the generator set if this kit has been installed. On the other hand, if it has not been installed, it is necessary to design the power and control part in order to operate the genset.
  • Page 55 Parallel operation If the parallel kit is not installed, the genset can be started and stopped manually or by CAN- BUS. The following instructions must be followed to operate manually. On the other hand, if CAN-BUS is used, follow the instructions of the installed controller. START THE GENSET 1.
  • Page 56: Section 9 - Technical Specifications

    Technical Specifications Section 9 – Technical specifications Solé, S.A. C-243 b, km 2 · 08760 Martorell (Barcelona) ·Tel. +34 93 775 14 00 · www.solediesel.com · info@solediesel.com Marine Diesel gensets. Operator’s Manual.
  • Page 57 MARINE GENERATORS 85 GT/GTC PARALLEL Three-Phase General data Maximum power*: 68 kW (85 kVA) Voltage: 400/230 V Prime Power**: 61,8 kW Amperage: 122,7 A Frequency: 50 Hz Phases: Dimensions and weights Total lenght without canopy: 1779 mm Total lenght with canopy: 2007 mm Total width without canopy: 866 mm...
  • Page 58 MARINE GENERATORS 100 GTA/GTAC PARALLEL Three-Phase General data Maximum power*: 77,8 kW (97,3 kVA) Voltage: 480/277 V Prime Power**: 70,8 kW Amperage: 117 A Frequency: 60 Hz Phases: Dimensions and weights Total lenght without canopy: 1779 mm Total lenght with canopy: 2007 mm Total width without canopy: 866 mm...
  • Page 59 MARINE GENERATORS 115 GT/GTC PARALLEL Three-Phase General data Maximum power*: 90 kW (112,4 kVA) Voltage: 400/230 V Prime Power**: 82 kW Amperage: 162,2 A Frequency: 50 Hz Phases: Dimensions and weights Total lenght without canopy: 1770 mm Total lenght with canopy: 2007 mm Total width without canopy: 865 mm...
  • Page 60 MARINE GENERATORS 120 GTA/GTAC PARALLEL Three-Phase General data Maximum power*: 96 kW (120 kVA) Voltage: 480/277 V Prime Power**: 87,3 kW Amperage: 144,3 A Frequency: 60 Hz Phases: Dimensions and weights Total lenght without canopy: 1769 mm Total lenght with canopy: 2007 mm Total width without canopy: 865 mm...
  • Page 61 MARINE GENERATORS 165 GT/GTC Three-Phase General data Maximum power*: 132 kW (165 kVA) Voltage: 400/230 V Prime Power**: 120 kW Amperage: 238,2 A Frequency: 50 Hz Phases: Dimensions and weights Total lenght without canopy: 2079 mm Total lenght with canopy:...
  • Page 62 MARINE GENERATORS 165 GT/GTC PARALLEL Three-Phase General data Maximum power*: 132 kW (165 kVA) Voltage: 400/230 V Prime Power**: 120 kW Amperage: 238,2 A Frequency: 50 Hz Phases: Dimensions and weights Total lenght without canopy: 2079 mm Total lenght with canopy:...
  • Page 63 MARINE GENERATORS 180 GTA/GTAC Three-Phase General data Maximum power*: 144 kW (180 kVA) Voltage: 480/277 V Prime Power**: 131 kW Amperage: 216 A Frequency: 60 Hz Phases: Dimensions and weights Total lenght without canopy: 2079 mm Total lenght with canopy: 2350 mm Total width without canopy: 804 mm...
  • Page 64 MARINE GENERATORS 180 GTA/GTAC PARALLEL Three-Phase General data Maximum power*: 144 kW (180 kVA) Voltage: 480/277 V Prime Power**: 131 kW Amperage: 216 A Frequency: 60 Hz Phases: Dimensions and weights Total lenght without canopy: 2079 mm Total lenght with canopy: 2350 mm Total width without canopy: 804 mm...
  • Page 65: Section 10 - Tightening Torques

    Tightening torques Section 10 – Tightening torques S DZ -1 6 5 / 2 0 5 / 2 8 0 TOR QUE VAL UES N·m kgf·m 1st Tightening 50 1st Tightening 5 Cylinder head 2nd Tightening 130 2nd Tightening13 Tightening 90º Tightening 90º...
  • Page 66: Section 11 - Technical Appendices

    Technical appendices Section 11 – Technical appendices Solé, S.A. C-243 b, km 2 · 08760 Martorell (Barcelona) ·Tel. +34 93 775 14 00 · www.solediesel.com · info@solediesel.com Marine Diesel gensets. Operator’s Manual.
  • Page 67: 11.1. Wiring Diagrams

    Technical appendices 11.1. Wiring diagrams Solé, S.A. C-243 b, km 2 · 08760 Martorell (Barcelona) ·Tel. +34 93 775 14 00 · www.solediesel.com · info@solediesel.com Marine Diesel gensets. Operator’s Manual.
  • Page 68 ECU CONNECTION EQUIPMENT PLUG / CONECTOR EQUIPOS A ECU Fault indicator lamp / Lampara indicadora de fallo Fault lamp test / Pu lsador test lampara de fallo ECU CONNECTION ENGINE PLUG / CONECTOR MOTOR A ECU Emergency stop relay Cranking relay ECU power relay Relé...
  • Page 69 ECU CONNECTION EQUIPMENT PLUG / CONECTOR EQUIPOS A ECU Fault indicator lamp / Lampara indicadora de fallo Fault lamp test / Pulsador test lampara de fallo Cranking relay ECU power relay Relé de arranque Relé alimentación ECU 30 86 85 87 30 86 85 87 reserve...
  • Page 70 ECU ENGINE AND EQUIPMENT ECU CONNECTION EQUIPMENT PLUG DETAIL / PLUGS DETAILS / DETALLE ECU CONECTORES DETALLE CONECTOR EQUIPOS COLOR Ó I MOTOR Y EQUIPOS A ECU Black / Negro Bat tery - / - Baterí a Spare / Libre Black / Negro DigOut/DIgIN Spare / Libre...
  • Page 71 Sec. 1 mm Sec. 1 mm Sec. 1 mm CONNECTOR ENGINE-ECU WIRING CPC 37 PIN PIN FEMALE ELECTRIC DIAGRAM FOR GENSET 165 GT/GTC AND 180 GTA/GTAC Part of the scheme: Engine installation (60996204) VERIFIED CREATION DATE LAST REVISION DRAWN PAGE 19/06/2018 DANIEL R.
  • Page 72 /3.B3 Sec. 1 mm 150 k Ω CONNECTOR ENGINE-ECU WIRING CPC 37 PIN PIN MALE ELECTRIC DIAGRAM FOR GENSET 165 GT/GTC AND 180 GTA/GTAC Part of the scheme: Box ECU and SCO-10 24V (60996217) VERIFIED CREATION DATE LAST REVISION DRAWN...
  • Page 73 RELAY 24V /2.C2 Sec. 1 mm /2.B4 /2.C2 2.5 A /2.C2 Sec. 1 mm ELECTRIC DIAGRAM FOR GENSET 165 GT/GTC AND 180 GTA/GTAC Part of the scheme: Box ECU and SCO-10 24V (60996217) VERIFIED CREATION DATE LAST REVISION DRAWN PAGE 19/06/2018 DANIEL R.
  • Page 74: 11.2. Alternator Connections

    Technical appendices 11.2. Alternator connections According to genset model, consult the alternator’s connection: CONNECTION’S TYPE 1 19 GSC / 23 GSAC / 20 GTC / 25 GTAC / 20 GSC / 25 GSAC / 25 GTC / 30 GTAC / 35 GTC / 40 GT CONNECTION’S TYPE 2 29 GSC / 32 GSAC / 50 GTC / 60 GTAC Connection’s type 1 Solé, S.A.
  • Page 75 Technical appendices Solé, S.A. C-243 b, km 2 · 08760 Martorell (Barcelona) ·Tel. +34 93 775 14 00 · www.solediesel.com · info@solediesel.com Marine Diesel gensets. Operator’s Manual.
  • Page 76: Connection Type 2

    Technical appendices Connection type 2 Solé, S.A. C-243 b, km 2 · 08760 Martorell (Barcelona) ·Tel. +34 93 775 14 00 · www.solediesel.com · info@solediesel.com Marine Diesel gensets. Operator’s Manual.
  • Page 77: 11.3. Regulator Connections

    Technical appendices 11.3. Regulator connections According to genset model, consult the regulator’s connection: CONNECTION’S TYPE 1 19 GSC / 23 GSAC / 20 GTC / 25 GTAC / 20 GSC / 25 GSAC / 25 GTC / 30 GTAC / 35 GTC / 40 GT CONNECTION’S TYPE 2 29 GSC / 32 GSAC / 50 GTC / 60 GTAC Connection’s type 1 Solé, S.A.
  • Page 78 Technical appendices Solé, S.A. C-243 b, km 2 · 08760 Martorell (Barcelona) ·Tel. +34 93 775 14 00 · www.solediesel.com · info@solediesel.com Marine Diesel gensets. Operator’s Manual.
  • Page 79: Connection's Type 2

    Technical appendices Connection’s type 2 Solé, S.A. C-243 b, km 2 · 08760 Martorell (Barcelona) ·Tel. +34 93 775 14 00 · www.solediesel.com · info@solediesel.com Marine Diesel gensets. Operator’s Manual.
  • Page 80: 11.4. Overall Dimensions

    Technical appendices 11.4. Overall dimensions Solé, S.A. C-243 b, km 2 · 08760 Martorell (Barcelona) ·Tel. +34 93 775 14 00 · www.solediesel.com · info@solediesel.com Marine Diesel gensets. Operator’s Manual.
  • Page 81 (USE ONLY FOR A REFERENCE) 1750 1774.5 Detail A (Fuel Inlet) VIEW A 327.5 147.5 Detail B (Fuel Outlet) (10x) Ø17 VIEW B mounting holes Detail D (Wet Exhaust) Detail C (Sea water Inlet) 85 GT / 100 GTA / 115 GT / 120 GTA MATERIAL ACABADO PRESENTACIÓN...
  • Page 82 (USE ONLY FOR A REFERENCE) SIPHON BREAK CONNECTIONS (AIR VENT SYSTEM-OPTIONAL KIT) VIEW E 217.5 225 327.5 DRY EXHAUST ACCESS (DRY EXHAUST - OPTIONAL KIT) Ø16 (x10) MOUNTING HOLES VIEW C VIEW A FAN INSIDE 1890 LEAKS COOLANT OUTLET (Ø8) SEA WATER OUTLET (Ø42) 2152 (ONLY DRY EXHAUST)
  • Page 83 EMERGENCY STOP 2350 SEA WATER INLET (Ø32) LEAKS COOLANT FUEL INLET (Ø12) FUEL OUTLET (Ø12) (ONLY DRY EXHAUST) OUTLET (Ø8) GRUPO 165 GT/GTC // 180 GTA/GTAC GENSET 165 GT/GTC // 180 GTA/GTAC MATERIAL ACABADO TRATAMIENTO PRESENTACIÓN ESCALA Suavizar Aristas DIBUJADO FECHA CREACIÓN...
  • Page 84 20.5 Detalle/Detail A Detalle/Detail C Detalle/Detail B Entrada agua mar/ (Entrada Gas-Oil/ (Entrada Gas-Oil/ Sea water Inlet Fuel Inlet) Fuel Inlet) 861.71 KIT ARMARIO/ ECU BOX KIT 2078.8 GRUPO 180 GTA 24V 480/277V ENGINE 180 GTA 24V 480/277V MATERIAL FINISH TREATMENT SCALE Remove All Burrs...
  • Page 85: Section 12 - Instructions To Replace And Remove

    Instructions to replace and remove Section 12 – Instructions to replace and remove When you decide to replace the genset, please contact Solé Diesel S.A.; will provide relevant instructions regarding the laws in force at the time. When disposing of the whole or parts of this genset, meets LAWS IN FORCE IN THE COUNTRY OF INSTALLATION.
  • Page 86: Section 13 - Inspection Prior To The Delivery Of Generator Sets

    Inspection prior to the delivery of generator sets Section 13 – Inspection prior to the delivery of generator sets Solé, S.A. C-243 b, km 2 · 08760 Martorell (Barcelona) ·Tel. +34 93 775 14 00 · www.solediesel.com · info@solediesel.com Marine Diesel gensets. Operator’s Manual.
  • Page 87 Inspection prior to the delivery of generator sets Solé, S.A. C-243 b, km 2 · 08760 Martorell (Barcelona) ·Tel. +34 93 775 14 00 · www.solediesel.com · info@solediesel.com Marine Diesel gensets. Operator’s Manual.
  • Page 88: Section 14 - Maintenance Log

    Maintenance log Section 14 - Maintenance log DATE HOURS DESCRIPTION SERVICE NAME Solé, S.A. C-243 b, km 2 · 08760 Martorell (Barcelona) ·Tel. +34 93 775 14 00 · www.solediesel.com · info@solediesel.com Marine Diesel gensets. Operator’s Manual.
  • Page 90 U_CTGR109280E_EN Revision 1 07/2022...

Table of Contents