In synergic mode, the welding voltage is not set directly by
user. The correct welding voltage will be set by the
machine's software.
Optimal voltage value is related to the input data:
Wire Feed Speed, WFS.
If it is needed, the welding voltage can be adjusted by the
Right Control [17]. When the right control is rotated, the
display will show a positive or negative bar indication if the
voltage is above or below the optimal voltage.
Voltage setup above
optimal value
Voltage
setup
at
optimal value
Voltage setup below
optimal value
Additionally can manually set:
Burnback
Run-In WFS
Preflow Time
Postflow Time
Spot Time
2-Step/4-Step
Crater
Polarity
Wave Control:
Pinch
Pinch controls the arc characteristics during short-arc
welding. Increasing Pinch Control results in a crisper arc
(more spatter) while decreasing provides a softer arc (less
spatter).
Adjust range: from -10 to +10.