Advanced Menu (Device Configuration Menu)
The Advanced Menu includes the parameters described in Table 7.
Table 7 The default settings of Advanced Menu
Parameter
English
The Menu Exit – enables exit from menu.
Note: This parameter cannot be edited.
To exit from menu:
In Advanced Menu select P000.
Confirm the selection, push the right button.
Wire Feed Speed (WFS) units – enables change WFS units:
CE (factory default) = m/min;
US = in/min.
Crater Delay - this option is used to skip the Crater sequence when
making short tack welds. If the trigger is released before the timer
expires, Crater will be bypassed and the weld will end. If the trigger
is released after the timer expires, the Crater sequence will function
normally (if enabled).
OFF (0) to 10.0 seconds (default = OFF)
Display Trim as Volts Option – determines how Trim is displayed:
"Yes" = all trim values are displayed as a voltage;
"No" = the trim is displayed in the format defined in the weld set.
Note: This option may not be available on all machines. The power
source must support this functionality, or this option will not appear
in the menu.
Arc Start / Loss Error Time - This option can be used to optionally
shut off output if an arc is not established, or is lost for a specified of
time. Error 269 will be displayed if the machine times out. If the
value is set to OFF, machine output will not be turned off if an arc is
not established or arc is lost. The trigger can be used to hot feed the
wire (default). If a value is set, the machine output will shut off if an
arc is not established within the specified amount of time after the
trigger is pulled or if the trigger remains pulled after an arc is lost. To
prevent nuisance errors, set Arc Start/Loss Error Time to an
appropriate value after considering all welding parameters (run-in
wire feed speed, weld wire feed speed, electrical stick out, etc).
OFF (0) to 10.0 seconds (default = Off)
Note: This parameter is disabled while welding in Stick, TIG or
Gouge.
Display Workpoint as Amps Option – determines how workpoint
is displayed:
"No" (factory default) = the workpoint is displayed in the format
defined in the weld set.
"Yes" = all workpoint values are displayed as an amperage.
Note: This option may not be available on all machines. The power
source must support this functionality, or this option will not appear
in the menu.
Feedback Persist – determines how feedback values are displayed
following a weld:
"No" (factory default) – last recorded feedback values will blink
for 5 seconds following a weld, then return to present display
mode.
"Yes" – last recorded feedback values will blink indefinitely
following a weld until a Control or Button is touched, or an arc is
struck.
Sense From Studs - Use this option for diagnostic purposes only.
When power is cycled, this option is automatically reset to False.
"No" = Voltage sensing is automatically determined by the
selected weld mode and other machine settings.
"Yes" = Voltage sensing is forced to "studs" of the power source.
Note: This option may not be available on all machines. The power
source must support this functionality, or this option will not appear
in the menu.