Summary of Contents for Supermicro AS-1013S-MTR

  • Page 1 A+ Server AS -1013S-MTR USER’S MANUAL Revision 1.0...
  • Page 2 State of California, USA. The State of California, County of Santa Clara shall be the exclusive venue for the resolution of any such disputes. Supermicro's total liability for all claims will not exceed the price paid for the hardware product.
  • Page 3 If you have any questions, please contact our support team at: support@supermicro.com This manual may be periodically updated without notice. Please check the Supermicro website for possible updates to the manual revision level. Warnings Special attention should be given to the following symbols used in this manual.
  • Page 4: Table Of Contents

    Preface Contents Chapter 1 Introduction 1.1 Overview ..........................8 1.2 Unpacking the System ......................8 1.3 System Features ........................9 1.4 Server Chassis Features ....................10 Control Panel ........................10 Front Features ........................11 Rear Features ........................12 1.5 Motherboard Layout ......................12 Quick Reference Table ......................14 Chapter 2 Server Installation 2.1 Overview ..........................17 2.2 Preparing for Setup ......................17 Choosing a Setup Location ....................17...
  • Page 5 A+ Server AS -1013S-MTR User's Manual Memory Support ......................31 DIMM Module Population ....................32 DIMM Installation ......................33 DIMM Removal .........................33 PCI Expansion Card Installation ..................34 Motherboard Battery ......................34 3.4 Chassis Components ......................35 Hard Drives ........................35 Hard Drive Carrier Indicators ..................36 Installing an M.2 Solid State Drive ..................37 System Cooling .........................38 Installing Fans ........................38 Air Shroud ........................38...
  • Page 6 Preface Chapter 6 BIOS 6.1 Introduction .........................59 Starting the Setup Utility ....................59 6.2 Main Setup .........................60 6.3 Advanced ..........................62 6.4 IPMI ............................77 6.5 Event Logs .........................80 6.6 Security ..........................82 6.7 Boot ............................85 6.8 Save & Exit .........................87 6.9 BIOS Update Using IPMI ....................89 Appendix A BIOS Codes Appendix B Standardized Warning Statements for AC Systems Appendix C System Specifications...
  • Page 7 Super Micro Computer, Inc. 980 Rock Ave. San Jose, CA 95131 U.S.A. Tel: +1 (408) 503-8000 Fax: +1 (408) 503-8008 Email: marketing@supermicro.com (General Information) support@supermicro.com (Technical Support) Website: www.supermicro.com Europe Address: Super Micro Computer B.V. Het Sterrenbeeld 28, 5215 ML...
  • Page 8: Overview

    A+ Server AS -1013S-MTR User's Manual Chapter 1 Introduction 1.1 Overview This chapter provides a brief outline of the functions and features of the AS -1013S-MTR. The AS -1013S-MTR is based on the H11SSL-i motherboard and the SC813MFTS-407CBP chassis. In addition to the motherboard and chassis, several important parts that are included with the system are listed below.
  • Page 9: System Features

    Chapter 1: Introduction 1.3 System Features The following table provides you with an overview of the main features of the AS -1013S-MTR. Please refer to Appendix C for additional specifications. System Features Motherboard H11SSL-i Chassis SC813MFTS-407CBP Single EPYC 7000 series processor Socket Type Socket SP3 Memory...
  • Page 10: Server Chassis Features

    A+ Server AS -1013S-MTR User's Manual 1.4 Server Chassis Features Control Panel The switches and LEDs located on the control panel are described below. See Chapter 4 for details on the control panel connections. Figure 1-1. Control Panel View Control Panel Features Item Feature Description...
  • Page 11: Front Features

    Chapter 1: Introduction Front Features The SC813MFTS-407CBP is a 1U chassis. See the illustration below for the features included on the front of the chassis. Figure 1-2. Chassis Front View Front Chassis Features Item Feature Description Hot-swap 3.5" SATA hard disk drive Control Panel Front control panel with LEDs and buttons (see preceding page) Rack Ear Brackets...
  • Page 12: Rear Features

    A+ Server AS -1013S-MTR User's Manual Rear Features The illustration below shows the features included on the rear of the chassis. Figure 1-3. Chassis Rear View Rear Chassis Features Item Feature Description Power Supply 400W single power supply (p/n PWS-407P-1R) I/O Back Panel Rear I/O ports (see Section 4.3) Expansion Card Slot...
  • Page 13 Chapter 1: Introduction USB0/1 UID-SW LAN1 IPMI LAN COM1 JPL2 UID-LED USB4/5 LAN2 LEDM1 JPL1 UID-LED JCOM1 LED1 COM1 JUIDB2 USB 0/1 FAN5 UID-SW IPMI_LAN FAN5 JPW1 LAN1 USB 4/5 (3.0) JPL2 BAR CODE JNCSI1 JPL1:LAN1 JPL2:LAN2 1-2 ENABLE 1-2 ENABLE 2-3 DISABLE 2-3 DISABLE LEDM1...
  • Page 14: Quick Reference Table

    A+ Server AS -1013S-MTR User's Manual Quick Reference Table Jumper Description Default Setting UID SW Unit ID switch (push-button toggle switch ON/OFF) JBT1 Clear CMOS Open (Normal) JPB1 BMC Enable/Disable Pins 1-2: (Enabled) JPG1 VGA Enable/Disable Pins 1-2 (Enabled) JPS1 SAS Enable/Disable (H11SSL-C &...
  • Page 15 Chapter 1: Introduction Connector Description JSTBY1 Stand by power header JIPMB1 4-pin BMC external IC header JPWR2 24-pin ATX power supply connector JPWR1 12V 8-pin ATX CPU power connector JPW1 4-pin ATX auxiliary power supply connector Front panel external speaker header PWRI2C Power supply SMBus I2C header LAN1, LAN2...
  • Page 16 A+ Server AS -1013S-MTR User's Manual H11SSL IPMI LAN COM1 RJ45 AMD SP3 Rev. 1.01 COM2 RTL8211F CPU PCIE P2[0~15] SLOT 4 DDR4 PCIE X16 AST2500 BMC ROM 32MB CPU USB1 [1] CPU PCIE P3[0~7] SLOT 5 LAN1 CPU PCIE P0 [8] BIOS ROM CPU PCIE_P0 [0] PCIE X8...
  • Page 17: Chapter 2 Server Installation

    A+ Server AS -1013S-MTR User's Manual Chapter 2 Server Installation 2.1 Overview This chapter provides advice and instructions for mounting your system in a server rack. If your system is not already fully integrated with processors, system memory etc., refer to Chapter 4 for details on installing those specific components.
  • Page 18: Server Precautions

    Chapter 2: Server Installation • In single rack installations, stabilizers should be attached to the rack. In multiple rack in- stallations, the racks should be coupled together. • Always make sure the rack is stable before extending a server or other component from the rack.
  • Page 19: Circuit Overloading

    A+ Server AS -1013S-MTR User's Manual Circuit Overloading Consideration should be given to the connection of the equipment to the power supply circuitry and the effect that any possible overloading of circuits might have on overcurrent protection and power supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern.
  • Page 20: Identifying The Sections Of The Rack Rails

    Chapter 2: Server Installation Identifying the Sections of the Rack Rails You may have received rack rail hardware with the AS -1013S-MTR. Two front inner rails should already be attached to the chassis. Note that these two rails are left/right specific. Locking Tabs: Both chassis rails have a locking tab, which serves two functions.
  • Page 21: Installing The Server Into The Rack

    A+ Server AS -1013S-MTR User's Manual Installing the Server into the Rack Install the server into the rack by lining up the rear of the chassis rails with the front of the rack rails. Slide the chassis rails into the rack rails, keeping the pressure even on both sides (you may have to depress the locking tabs when inserting).
  • Page 22: Installing The Server Into A Telco Rack

    Chapter 2: Server Installation Installing the Server into a Telco Rack To install the AS -1013S-MTR into a Telco type rack, use two L-shaped brackets on either side of the chassis (four total). 1. First, determine how far the server will extend out the front of the rack. Larger chassis should be positioned to balance the weight between front and back.
  • Page 23: Chapter 3 Maintenance And Component Installation

    A+ Server AS -1013S-MTR User's Manual Chapter 3 Maintenance and Component Installation This chapter provides instructions on installing and replacing main system components. To prevent compatibility issues, only use components that match the specifications and/or part numbers given. Installation or replacement of most components require that power first be removed from the system.
  • Page 24: Motherboard Components

    When receiving a motherboard without a processor pre-installed, make sure that the plastic CPU socket cap is in place and none of the socket pins are bent; otherwise, contact your retailer immediately. • Refer to the Supermicro website for updates on CPU support.
  • Page 25 A+ Server AS -1013S-MTR User's Manual Installing the Processor and Heatsink 1. Using a Torx T20 screwdriver, unscrew the screws holding down the force frame in the sequence of 3-2-1. The screws are numbered on the force frame next to each screw hole.
  • Page 26 Chapter 3: Maintenance and Component Installation 3. Lift the rail frame up by gripping the lift tabs near the front end of the rail frame. While keeping a secure grip of the rail frame, lift it to a position so you can do the next step of removing the external cap.
  • Page 27 A+ Server AS -1013S-MTR User's Manual 5. The CPU package is shipped from the factory with the blue carrier frame pre-assembled. Grip the handle of the carrier frame/CPU package assembly from its shipping tray, and while gripping the handle, align the flanges of the carrier frame onto the rails of the rail frame so its pins will be at the bottom when the rail frame is lowered later.
  • Page 28 Chapter 3: Maintenance and Component Installation 9. Gently lower the force frame down onto the rail frame and hold it in place until it is seated in the Socket housing. Note that the force frame is spring loaded and has to be held in place before it is secured.
  • Page 29 A+ Server AS -1013S-MTR User's Manual 11. After the force frame is secured and the CPU package is in place, now you must install the heatsink to the frame. Lower the heatsink down till it rests securely over the four screw holes on CPU package on the socket frame.
  • Page 30 Chapter 3: Maintenance and Component Installation Removing a Heatsink We do not recommend removing the heatsink. If necessary, please follow the instructions below to prevent damage to the CPU or the CPU socket. Note: Wait for the heatsink to cool down before removing it. 1.
  • Page 31: Memory Support And Installation

    A+ Server AS -1013S-MTR User's Manual Memory Support and Installation Note: Check the Supermicro website for recommended memory modules. Important: Exercise extreme care when installing or removing DIMM modules to prevent any possible damage. Memory Support The H11SSL-i supports Up to 1 TB of ECC DDR4-2666 MHz speed, RDIMM/LRDIMM/3DS/ NVDIMM memory in eight (8) slots.
  • Page 32: Dimm Module Population

    Chapter 3: Maintenance and Component Installation DIMM Module Population There is no specific order or sequence required when installing memory modules, but keep the following in mind: • Always use DDR4 DIMM modules of the same type, size and speed. •...
  • Page 33: Dimm Installation

    A+ Server AS -1013S-MTR User's Manual DIMM Installation 1. Insert the desired number of DIMMs into the memory slots, there is no specific sequence or order required Receptive 2. Push the release tab outwards on one Point end of the DIMM slot to unlock it. 3.
  • Page 34: Pci Expansion Card Installation

    Chapter 3: Maintenance and Component Installation PCI Expansion Card Installation The system includes a pre-installed riser card (p/n RSC-RR1U-E16) that positions a standard size PCI-E x16 card at a 90 degree angle, allowing it to fit inside the chassis. Installing PCI Expansion Cards Perform the following steps to install an add-on card: Begin by removing power from the system as described in Section 3.1 and the chassis cover as described in Section 3.2.
  • Page 35: Chassis Components

    A+ Server AS -1013S-MTR User's Manual 3.4 Chassis Components Hard Drives Your server may or may not have come with hard drives installed. Up to four 3.5" hot-swap hard drives are supported by the chassis. The SATA drives are mounted in drive carriers to simplify their installation and removal from the chassis.
  • Page 36: Hard Drive Carrier Indicators

    Hard Drive Carrier LED Indicators State/Condition Indication Green Blinking Indicates drive activity Solid on Indicates drive failure Note: Enterprise level hard disk drives are recommended for use in Supermicro chassis and servers. For information on recommended HDDs, visit the Supermicro website at http://www. supermicro.com/products/nfo/files/storage/SBB-HDDCompList.pdf...
  • Page 37: Installing An M.2 Solid State Drive

    A+ Server AS -1013S-MTR User's Manual Installing an M.2 Solid State Drive Note: There are some thermal limitations. Please contact Supermicro Support before installing an M.2 device. The motherboard can accommodate an M.2 solid state drive (SSD). The M.2 socket supports PCIe 3.0 x4 (32 Gb/s) SSD cards in the 2280 or 22110 form factors.
  • Page 38: System Cooling

    Chapter 3: Maintenance and Component Installation System Cooling Four 4-cm counter-rotating fans provide the cooling for the system. It is very important that the chassis top cover is installed for the cooling air to circulate properly through the chassis and cool the components. Installing Fans Fan speed is controlled by system temperature via IPMI.
  • Page 39: Dvd-Rom Drive Installation (Optional)

    A+ Server AS -1013S-MTR User's Manual DVD-ROM Drive Installation (Optional) The top cover of the chassis must be opened to gain full access to the DVD-ROM drive bay. The AS -1013S-MTR accommodates only slim DVD-ROM drives. Side mounting brackets (p/n MCP-220-81502-0N) are needed to mount a slim DVD-ROM drive into the server. You must power down the system before installing or removing a DVD-ROM drive.
  • Page 40: Power Supply

    The Power Fail LED will illuminate and remain on until the failed unit has been replaced. Replacement units can be ordered directly from Supermicro (see contact information in the Preface). The hot-swap capability of the power supply modules allows you to replace the failed module without powering down the system..
  • Page 41: Chapter 4 Motherboard Connections

    Chapter 4: Motherboard Connections Chapter 4 Motherboard Connections This section describes the connections on the motherboard and provides pinout definitions. Note that depending on how the system is configured, not all connections are required. The LEDs on the motherboard are also described here. A serverboard layout indicating component locations may be found in Chapter 1.
  • Page 42: Headers And Connectors

    A+ Server AS -1013S-MTR User's Manual 12V 8-pin Auxilliary Power Connector (JPWR1) JPWR1 is an 8-pin ATX power input to provide auxiliary power to the processor. Refer to the table below for pin definitions. 12V 8-pin Power Pin Definitions Pin# Definition 1 - 4 Ground...
  • Page 43 It enables the motherboard to deny access if the TPM associated with the hard drive is not installed in the system. Please go to the following link for more information on TPM: http://www.supermicro.com/ manuals/other/TPM.pdf. Trusted Platform Module Header...
  • Page 44 Sensor Header (JSEN1) This header (JSEN1) allows BMC to monitor thermal inlet temperature. A special module is required. Please contact Supermicro at www.supermicro.com to purchase the module for thisheader. Refer to the table below for pin definitions Intel Sensor Header...
  • Page 45 Chapter 4: Motherboard Connections Overheat LED/Fan Fail (JOH1) The JOH1 header is used to connect an LED indicator to provide warnings of chassis overheating or fan failure. This LED will blink when a fan failure occurs. Refer to the table on right for pin definitions.
  • Page 46 A+ Server AS -1013S-MTR User's Manual Speaker (JD1) On the JD1 header, pins 3~4 are used for the internal speaker. Close pins 3~4 with a cap to use the onboard speaker. If you wish to use an external speaker, attach an external speaker to pins 6~7.
  • Page 47: Control Panel

    Chapter 4: Motherboard Connections Control Panel JF1 contains header pins for various control panel connections. See the figure below for the pin locations and definitions of the control panel buttons and LED indicators. All JF1 wires have been bundled into a single cable to simplify this connection. Make sure the red wire plugs into pin 1 as marked on the motherboard.
  • Page 48 (e.g., a system rack with multiple units installed). Note: UID can also be triggered via IPMI on the serverboard. For more information on IPMI, please refer to the IPMI User's Guide posted on our website at http://www.supermicro.com. UID LED Pin Definitions (JF1)
  • Page 49 Chapter 4: Motherboard Connections HDD LED The HDD LED connection is located on pins 13 and 14 of JF1. Attach a cable to Pin 14 to show hard drive activity status. Refer to the table below for pin definitions. HDD LED Pin Definitions (JF1) Pin# Definition...
  • Page 50: Ports

    A+ Server AS -1013S-MTR User's Manual 4.3 Ports Rear I/O Ports See the figure below for the locations and descriptions of the various I/O ports on the rear of the motherboard. Figure 2-1. Rear I/O Ports Rear I/O Ports Description Description Description COM Port...
  • Page 51 LED indicators. The UID Indicator provides easy identification of a system that may be in need of service. Note: UID can also be triggered via IPMI on the serverboard. For more information on IPMI, please refer to the IPMI User's Guide posted on our website at http://www.supermicro.com...
  • Page 52: Jumpers

    A+ Server AS -1013S-MTR User's Manual 4.4 Jumpers Explanation of Jumpers To modify the operation of the motherboard, jumpers are used to choose between optional settings. Jumpers create shorts between two pins to change the function associated with it. Pin 1 is identified with a square solder pad on the printed circuit board. See the motherboard layout page for jumper locations.
  • Page 53 Chapter 4: Motherboard Connections VGA Enable/Disable JPG1 allows you to enable or disable the VGA port using the onboard graphics controller. The default setting is Enabled. VGA Enable/Disable Jumper Settings Jumper Setting Definition Pins 1-2 Enabled Pins 2-3 Disabled Watch Dog JWD1 controls the Watch Dog function.
  • Page 54: Led Indicators

    A+ Server AS -1013S-MTR User's Manual 4.5 LED Indicators LAN LEDs Each LAN port has two LED indicators. The yellow LED indicates activity, while the link LED may be green, amber, or off to indicate the speed of the connection. See the tables below for more information.
  • Page 55: Chapter 5 Software

    You must first configure RAID settings (if using RAID) before you install the Windows OS and the software drivers. To configure RAID settings, please refer to the RAID Configuration User Guides posted on our website at www.supermicro.com/support/manuals. Installing the Windows OS for a RAID System 1.
  • Page 56: Driver Installation

    A+ Server AS -1013S-MTR User's Manual 5.2 Driver Installation The Supermicro FTP site contains drivers and utilities for your system at ftp://ftp.supermicro. com. Some of these must be installed, such as the chipset driver. After accessing the FTP site, go into the CDR_Images directory and locate the ISO file for your motherboard.
  • Page 57: Superdoctor ® 5

    5.3 SuperDoctor ® The Supermicro SuperDoctor 5 is a program that functions in a command-line or web-based interface for Windows and Linux operating systems. The program monitors such system health information as CPU temperature, system voltages, system power consumption, fan speed, and provides alerts via email or Simple Network Management Protocol (SNMP).
  • Page 58: Ipmi

    The H11SSL-i support the Intelligent Platform Management Interface (IPMI). IPMI is used to provide remote access, monitoring and management. There are several BIOS settings that are related to IPMI. For general documentation and information on IPMI, please visit our website at: http://www.supermicro.com/products/nfo/IPMI.cfm.
  • Page 59: Chapter 6 Bios

    Chapter 6: BIOS Chapter 6 BIOS 6.1 Introduction This chapter describes the AMIBIOS™ Setup utility for the H11SSL-i motherboard. The BIOS is stored on a chip and can be easily upgraded using a flash program. Note: Due to periodic changes to the BIOS, some settings may have been added or deleted and might not yet be recorded in this manual.
  • Page 60: Main Setup

    Note: The time is in the 24-hour format. For example, 5:30 P.M. appears as 17:30:00. The date's default value is 01/01/2015 after RTC reset. Supermicro H11SSL-i / H11SSL-C / H11SSL-NC BIOS Version This item displays the version of the BIOS ROM used in the system.
  • Page 61 Chapter 6: BIOS CPLD Version This item displays the CPLD version of the BIOS ROM used in the system. Memory Information Total Memory This item displays the total size of memory available in the system.
  • Page 62: Advanced

    A+ Server AS -1013S-MTR User's Manual 6.3 Advanced Use the arrow keys to select Boot Setup and press <Enter> to access the submenu items. Warning: Take caution when changing the Advanced settings. An incorrect value, a very high DRAM frequency, or an incorrect DRAM timing setting may make the system unstable.
  • Page 63 Chapter 6: BIOS Bootup NumLock State Use this feature to set the Power on state for the <Numlock> key. The options are Off and On. Wait For "F1" If Error Use this feature to force the system to wait until the 'F1' key is pressed if an error occurs. The options are Disabled and Enabled.
  • Page 64 A+ Server AS -1013S-MTR User's Manual Trusted Computing  Security Device Support If this feature and the TPM jumper on the motherboard are both set to Enabled, onboard security devices will be enabled for TPM (Trusted Platform Module) support to enhance data integrity and network security.
  • Page 65 Chapter 6: BIOS CPU Configuration  SMT Mode Use this setting to specify Simultaneous Multithreading. Options include Off for 1T single thread and Auto for 2T two-thread if your system is capable of it. Core Performance Boost This setting is used to configure for Core Performance Boost. Options include Auto and Disabled.
  • Page 66 A+ Server AS -1013S-MTR User's Manual CPU1 Information  These sections are for informational purposes. They will display some details about the detected CPUs on the motherboard, such as: • CPU Version • Number of Cores Running • Processor Family •...
  • Page 67 Chapter 6: BIOS Memory Interleaving Size This setting controls the memory interleaving size. This determines the starting address of the interleave (bit 8, 9, 10 or 11). Options include 256 Bytes, 512 Bytes, 1 KB, 2 KB or Auto. Chipset Interleaving When enabled, this setting will interleave memory blocks across the DRAM selects for Node 0.
  • Page 68 A+ Server AS -1013S-MTR User's Manual Change Settings This feature specifies the base I/O port address and the Interrupt Request address of a serial port specified by the user. Select Auto to allow the BIOS to automatically assign the base I/O and IRQ address. The options are Auto, (IO=3F8h; IRQ=4;); (IO=3F8h; IRQ=3, 4, 5, 6, 7, 9, 10, 11, 12;);...
  • Page 69 Chapter 6: BIOS Bits per second Use this feature to set the transmission speed for a serial port used in Console Redirection. Make sure that the same speed is used in the host computer and the client computer. A lower transmission speed may be required for long and busy lines. The options are 9600, 19200, 38400, 57600 and 115200 (bits per second).
  • Page 70 A+ Server AS -1013S-MTR User's Manual Putty KeyPad This feature selects the settings for Function Keys and KeyPad used for Putty, which is a terminal emulator designed for the Windows OS. The options are VT100, LINUX, XTERMR6, SC0, ESCN, and VT400. Console Redirection Select Enabled to enable SOL console redirection support for a serial port specified by the user.
  • Page 71 Chapter 6: BIOS Stop Bits A stop bit indicates the end of a serial data packet. Select 1 Stop Bit for standard serial data communication. Select 2 Stop Bits if slower devices are used. The options are 1 and 2. Flow Control Use this feature to set the flow control for Console Redirection to prevent data loss caused by buffer overflow.
  • Page 72 A+ Server AS -1013S-MTR User's Manual Console Redirection is enabled for legacy OS systems. Default option for this system is Always Enable. Serial Port for Out-of-Band Management/Windows Emergency Management Services (EMS) Console Redirection Select Enabled to enable EMS console redirection support for a serial port specified by the user.
  • Page 73 Chapter 6: BIOS PCIe/PCI/PnP Configuration This menu provides PCIe/PCI/PnP configuration settings and information. PCI Bus Driver Version Above 4G Decoding This setting Enables or Disables 64-bit capable devices ability to be decoded in above 4G address space (only if the system supports 64-bit PCI decoding). SR-IOV Support If the system has SR-IOV capable PCI-E devices, this setting will Enable or Disable the Single Root IO Virtualization Support for the system.
  • Page 74 A+ Server AS -1013S-MTR User's Manual CPU Slot 2 PCI-E x16 OPROM This setting enables or disables the listed PCI/PCIX/PCIe Slot OPROM option. Options include Disabled, Legacy or EFI. CPU Slot 3 PCI-E x8 OPROM This setting enables or disables the listed PCI/PCIX/PCIe Slot OPROM option. Options include Disabled, Legacy or EFI.
  • Page 75 Chapter 6: BIOS JNVMe0 OpROM Use this setting to select which firmware function is to be loaded for JNVMe0 OpROM on the system. Options include Disabled, and EFI. JNVMe1 OpROM Use this setting to select which firmware function is to be loaded for JNVMe1 OpROM on the system.
  • Page 76 A+ Server AS -1013S-MTR User's Manual iSCSI Configuration  iSCSI Initiator Name This feature allows the user to enter the unique name of the iSCSI Initiator in IQN format. Once the name of the iSCSI Initiator is entered into the system, configure the proper settings for the following items.
  • Page 77: Ipmi

    Chapter 6: BIOS 6.4 IPMI This tab allows you to configure the following IPMI settings for the system. Use this feature to configure Intelligent Platform Management Interface (IPMI) settings. BMC Firmware Revision This item indicates the IPMI firmware revision used in your system. IPMI Status (Baseboard Management Controller) This item indicates the status of the IPMI firmware installed in your system.
  • Page 78 A+ Server AS -1013S-MTR User's Manual Erasing Settings Erase SEL Select Yes, On next reset to erase all system event logs upon next system reboot. Select Yes, On every reset to erase all system event logs upon each system reboot. Select No to keep all system event logs after each system reboot.
  • Page 79 Chapter 6: BIOS Station IP Address This item displays the Station IP address for this computer. This should be in decimal and in dotted quad form. Subnet Mask This item displays the sub-network that this computer belongs to. The value of each three- digit number separated by dots should not exceed 255.
  • Page 80: Event Logs

    A+ Server AS -1013S-MTR User's Manual 6.5 Event Logs This tab allows the user to configure the following event logs settings for the system. Change SMBIOS Event Log Settings  This feature allows the user to configure SMBIOS Event settings. Enabling/Disabling Options SMBIOS Event Log Select Enabled to enable SMBIOS (System Management BIOS) Event Logging during...
  • Page 81 Chapter 6: BIOS When Log is Full Select Erase Immediately to immediately erase all errors in the SMBIOS event log when the event log is full. Select Do Nothing for the system to do nothing when the SMBIOS event log is full. The options are Do Nothing and Erase Immediately. SMBIOS Event Log Standard Settings Log System Boot Event Select Enabled to log system boot events.
  • Page 82: Security

    A+ Server AS -1013S-MTR User's Manual 6.6 Security This tab allows you to configure the following security settings for the system. Administrator Password Press Enter to create a new, or change an existing Administrator password. Note that if the Administrator Password is erased, the User Password will be cleared as well. User Password Press Enter to create a new, or change an existing User password.
  • Page 83 Chapter 6: BIOS Attempt Secure Boot This option allows you specify when the Platform Key (PK) is enrolled. When enabled, the System Mode is user deployed, and the CSM function is disabled. Options include Enabled and Disabled. Secure Boot Mode Use this item to select the secure boot mode.
  • Page 84 A+ Server AS -1013S-MTR User's Manual Append Key Select Yes to add the KEK from the manufacturer's defaults list to the existing KEK. Select No to load the KEK from a file. The options are Yes and No.  Authorized Signatures Set New Key Select Yes to load the database from the manufacturer's defaults.
  • Page 85: Boot

    Chapter 6: BIOS 6.7 Boot Use this tab to configure Boot Settings: Boot Mode Select Use this item to select the type of device that the system is going to boot from. The options are LEGACY, UEFI, and DUAL. The default setting is DUAL. Legacy to EFI Support This option Enables or Disables the system to boot to an EFI OS after the boot failed from the legacy boot order.
  • Page 86 A+ Server AS -1013S-MTR User's Manual  UEFI Application Boot Priorities This feature allows the user to specify which UEFI devices are boot devices. • UEFI Boot Order #1  NETWORK Drive BBS Priorities This feature allows the user to specify which UEFI network drive devices are boot devices.
  • Page 87: Save & Exit

    Chapter 6: BIOS 6.8 Save & Exit Select the Save & Exit tab to enter the Save & Exit BIOS Setup screen. Discard Changes and Exit Select this option to quit the BIOS Setup without making any permanent changes to the system configuration, and reboot the computer.
  • Page 88 A+ Server AS -1013S-MTR User's Manual Default Options Restore Defaults To set this feature, select Restore Defaults from the Save & Exit menu and press <Enter>. These are factory settings designed for maximum system stability, but not for maximum performance. Save as User Defaults To set this feature, select Save as User Defaults from the Exit menu and press <Enter>.
  • Page 89: Bios Update Using Ipmi

    If necessary, the system BIOS can be updated using IPMI. Documentation on IPMI is available at http://www.supermicro.com/products/nfo/IPMI.cfm. 1. Download the BIOS file using the link on the server web page. Unzip and save it. 2. Access the IPMI web interface. Enter the IP address and log in. The default username and password are ADMIN/ADMIN.
  • Page 90 A+ Server AS -1013S-MTR User's Manual Start Button Clear Checkboxes Verify Date Figure 6-3. Start Upgrade Dialog 6. In the Start Upgrade dialog, make sure the three checkboxes are not checked, and verify the date of the BIOS file you uploaded before proceeding. 7.
  • Page 91: Appendix A Bios Codes

    When BIOS performs the Power On Self Test, it writes checkpoint codes to I/O port 0080h. If the computer cannot complete the boot process, a diagnostic card can be attached to the computer to read I/O port 0080h (Supermicro p/n AOC-LPC80-20). For information on AMI updates, please refer to http://www.ami.com/products/.
  • Page 92: Appendix B Standardized Warning Statements For Ac Systems

    Supermicro's Technical Support department for assistance. Only certified technicians should attempt to install or configure components. Read this appendix in its entirety before installing or configuring components in the Supermicro chassis. These warnings may also be found on our website at http://www.supermicro.com/about/...
  • Page 93 Appendix B: Standardized Warning Statements Warnung WICHTIGE SICHERHEITSHINWEISE Dieses Warnsymbol bedeutet Gefahr. Sie befinden sich in einer Situation, die zu Verletzungen führen kann. Machen Sie sich vor der Arbeit mit Geräten mit den Gefahren elektrischer Schaltungen und den üblichen Verfahren zur Vorbeugung vor Unfällen vertraut. Suchen Sie mit der am Ende jeder Warnung angegebenen Anweisungsnummer nach der jeweiligen Übersetzung in den übersetzten Sicherheitshinweisen, die zusammen mit diesem Gerät ausgeliefert wurden.
  • Page 94 A+ Server AS -1013S-MTR User's Manual . ٌ ‫ا ك ً ف حالة و ٌ يك أى تتسبب ف اصابة جسذ ة ٌ هذا الزهز ع ٌ خطز !تحذ ز‬ ‫قبل أى تعول عىل أي هعذات،يك عىل علن بالوخاطز ال ا ٌجوة عي الذوائز‬ ٍ...
  • Page 95 Appendix B: Standardized Warning Statements Warnung Vor dem Anschließen des Systems an die Stromquelle die Installationsanweisungen lesen. ¡Advertencia! Lea las instrucciones de instalación antes de conectar el sistema a la red de alimentación. Attention Avant de brancher le système sur la source d'alimentation, consulter les directives d'installation. .‫יש...
  • Page 96 A+ Server AS -1013S-MTR User's Manual Warnung Dieses Produkt ist darauf angewiesen, dass im Gebäude ein Kurzschluss- bzw. Überstromschutz installiert ist. Stellen Sie sicher, dass der Nennwert der Schutzvorrichtung nicht mehr als: 250 V, 20 A beträgt. ¡Advertencia! Este equipo utiliza el sistema de protección contra cortocircuitos (o sobrecorrientes) del edificio.
  • Page 97 Appendix B: Standardized Warning Statements Power Disconnection Warning Warning! The system must be disconnected from all sources of power and the power cord removed from the power supply module(s) before accessing the chassis interior to install or remove system components. 電源切断の警告...
  • Page 98 A+ Server AS -1013S-MTR User's Manual ‫يجب فصم اننظاو من جميع مصادر انطاقت وإ ز انت سهك انكهرباء من وحدة امداد‬ ‫انطاقت قبم‬ ‫انىصىل إىن امنناطق انداخهيت نههيكم نتثبيج أو إ ز انت مكىناث الجهاز‬ 경고! 시스템에 부품들을 장착하거나 제거하기 위해서는 섀시 내부에 접근하기 전에 반드시 전원 공급장치로부터...
  • Page 99 Appendix B: Standardized Warning Statements Attention Il est vivement recommandé de confier l'installation, le remplacement et la maintenance de ces équipements à des personnels qualifiés et expérimentés. !‫אזהרה‬ .‫צוות מוסמך בלבד רשאי להתקין, להחליף את הציוד או לתת שירות עבור הציוד‬ ‫واملدربيه...
  • Page 100 A+ Server AS -1013S-MTR User's Manual Warnung Diese Einheit ist zur Installation in Bereichen mit beschränktem Zutritt vorgesehen. Der Zutritt zu derartigen Bereichen ist nur mit einem Spezialwerkzeug, Schloss und Schlüssel oder einer sonstigen Sicherheitsvorkehrung möglich. ¡Advertencia! Esta unidad ha sido diseñada para instalación en áreas de acceso restringido. Sólo puede obtenerse acceso a una de estas áreas mediante la utilización de una herramienta especial, cerradura con llave u otro medio de seguridad.
  • Page 101 Appendix B: Standardized Warning Statements Battery Handling Warning! There is the danger of explosion if the battery is replaced incorrectly. Replace the battery only with the same or equivalent type recommended by the manufacturer. Dispose of used batteries according to the manufacturer's instructions 電池の取り扱い...
  • Page 102 A+ Server AS -1013S-MTR User's Manual ‫هناك خطر من انفجار يف حالة اسحبذال البطارية بطريقة غري صحيحة فعليل‬ ‫اسحبذال البطارية‬ ‫فقط بنفس النىع أو ما يعادلها مام أوصث به الرشمة املصنعة‬ ‫جخلص من البطاريات املسحعملة وفقا لحعليامت الرشمة الصانعة‬ 경고! 배터리가...
  • Page 103 Appendix B: Standardized Warning Statements ¡Advertencia! Puede que esta unidad tenga más de una conexión para fuentes de alimentación. Para cortar por completo el suministro de energía, deben desconectarse todas las conexiones. Attention Cette unité peut avoir plus d'une connexion d'alimentation. Pour supprimer toute tension et tout courant électrique de l'unité, toutes les connexions d'alimentation doivent être débranchées.
  • Page 104 A+ Server AS -1013S-MTR User's Manual Backplane Voltage Warning! Hazardous voltage or energy is present on the backplane when the system is operating. Use caution when servicing. バックプレーンの電圧 システムの稼働中は危険な電圧または電力が、 バックプレーン上にかかっています。 修理する際には注意く ださい。 警告 当系统正在进行时,背板上有很危险的电压或能量,进行维修时务必小心。 警告 當系統正在進行時,背板上有危險的電壓或能量,進行維修時務必小心。 Warnung Wenn das System in Betrieb ist, treten auf der Rückwandplatine gefährliche Spannungen oder Energien auf.
  • Page 105 Appendix B: Standardized Warning Statements ‫هناك خطز مه التيار الكهزبايئ أوالطاقة املىجىدة عىل اللىحة‬ ‫عندما يكىن النظام يعمل كه حذ ر ا عند خدمة هذا الجهاس‬ 경고! 시스템이 동작 중일 때 후면판 (Backplane)에는 위험한 전압이나 에너지가 발생 합니다. 서비스 작업 시 주의하십시오. Waarschuwing Een gevaarlijke spanning of energie is aanwezig op de backplane wanneer het systeem in gebruik is.
  • Page 106 A+ Server AS -1013S-MTR User's Manual ‫תיאום חוקי החשמל הארצי‬ !‫אזהרה‬ .‫התקנת הציוד חייבת להיות תואמת לחוקי החשמל המקומיים והארציים‬ ‫تركيب املعدات الكهربائية يجب أن ميتثل للقىاويه املحلية والىطىية املتعلقة‬ ‫بالكهرباء‬ 경고! 현 지역 및 국가의 전기 규정에 따라 장비를 설치해야 합니다. Waarschuwing Bij installatie van de apparatuur moet worden voldaan aan de lokale en nationale elektriciteitsvoorschriften.
  • Page 107 Appendix B: Standardized Warning Statements Attention La mise au rebut ou le recyclage de ce produit sont généralement soumis à des lois et/ou directives de respect de l'environnement. Renseignez-vous auprès de l'organisme compétent. ‫סילוק המוצר‬ !‫אזהרה‬ .‫סילוק סופי של מוצר זה חייב להיות בהתאם להנחיות וחוקי המדינה‬ ‫التخلص...
  • Page 108 A+ Server AS -1013S-MTR User's Manual Warnung Gefährlich Bewegende Teile. Von den bewegenden Lüfterblätter fern halten. Die Lüfter drehen sich u. U. noch, wenn die Lüfterbaugruppe aus dem Chassis genommen wird. Halten Sie Finger, Schraubendreher und andere Gegenstände von den Öffnungen des Lüftergehäuses entfernt.
  • Page 109 Verbindungskabeln, Stromkabeln und/oder Adapater, die Ihre örtlichen Sicherheitsstandards einhalten. Der Gebrauch von anderen Kabeln und Adapter können Fehlfunktionen oder Feuer verursachen. Die Richtlinien untersagen das Nutzen von UL oder CAS zertifizierten Kabeln (mit UL/CSA gekennzeichnet), an Geräten oder Produkten die nicht mit Supermicro gekennzeichnet sind.
  • Page 110 ‫.قيرح وأ لطع يف ببستي دق ىرخأ تالوحمو تالباك يأ مادختسا .ميلسلا سباقلاو لصوملا مجح‬ ‫ لبق نم ةدمتعملا تالباكلا مادختسا تادعملاو ةيئابرهكلا ةزهجألل ةمالسلا نوناق رظحي‬UL ‫ وأ‬CSA ‫( ةمالع لمحت يتلاو‬UL/CSA) ‫ لبق نم ةددحملاو ةينعملا تاجتنملا ريغ ىرخأ تادعم يأ عم‬Supermicro.
  • Page 111 사항을 준수하여 제공되거나 지정된 연결 혹은 구매 케이블, 전원 케이블 및 AC 어댑터를 사용하십시오. 다른 케이블이나 어댑터를 사용하면 오작동이나 화재가 발생할 수 있습니다. 전기 용품 안전법은 UL 또는 CSA 인증 케이블 (코드에 UL / CSA가 표시된 케이블)을 Supermicro 가 지정한 제품 이외의 전기 장치에 사용하는 것을 금지합니다. Stroomkabel en AC-Adapter...
  • Page 112: Appendix C System Specifications

    A+ Server AS -1013S-MTR User's Manual Appendix C System Specifications Processors Single EPYC 7000 series processor in a Socket SP3 type socket Note: Please refer to the motherboard specifications pages on our website for updates to supported processors. Chipset AMD SoC (System on Chip) chipset BIOS 128 Mb SPI AMI SM Flash UEFI BIOS...
  • Page 113 Appendix C: System Specifications Regulatory Compliance Electromagnetic Emissions: FCC Class A, EN 55032 Class A, EN 61000-3-2/3-3, CISPR 32 Class A Electromagnetic Immunity: EN 55024/CISPR 24, (EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-4-11) Safety: CSA/EN/IEC/UL 60950-1 Compliant, UL or CSA Listed (USA and Canada), CE Marking (Europe) Other: VCCI-CISPR 32 and AS/NZS CISPR 32 Environmental: Directive 2011/65/EU and Directive 2012/19/EU...
  • Page 114: Appendix D Uefi Bios Recovery

    Warning: Do not upgrade the BIOS unless your system has a BIOS-related issue. Flashing the wrong BIOS can cause irreparable damage to the system. In no event shall Supermicro be liable for direct, indirect, special, incidental, or consequential damages arising from a BIOS update.
  • Page 115 1. Using a different system, copy the "Super.ROM" binary image file into the disc Root "\" Directory of a USB device or a writable CD/DVD. Note: If you cannot locate the "Super.ROM" file in your driver disk, visit our website www.supermicro.com to download the BIOS image into a USB flash device and rename it "Super.ROM".
  • Page 116 A+ Server AS -1013S-MTR User's Manual 3. While powering on the system, please keep pressing <Ctrl> and <Home> simultaneously on your keyboard until the following screen (or a screen similar to the one below) displays. 4. After locating the new BIOS binary image, the system will enter the BIOS Recovery menu as shown below.
  • Page 117 Appendix D: UEFI BIOS Recovery 5. When the screen as shown above displays, use the arrow keys to select the item "Proceed with flash update" and press the <Enter> key. You will see the BIOS recovery progress as shown in the screen below. Note: Do not interrupt the BIOS flashing process until it has completed.