  • Page 1 A+ Server AS -1024US-TRT USER’S MANUAL Revision 1.0b...
  • Page 2 State of California, USA. The State of California, County of Santa Clara shall be the exclusive venue for the resolution of any such disputes. Supermicro's total liability for all claims will not exceed the price paid for the hardware product.
  • Page 3 If you have any questions, please contact our support team at: support@supermicro.com This manual may be periodically updated without notice. Please check the Supermicro website for possible updates to the manual revision level. Secure Data Deletion A secure data deletion tool designed to fully erase all data from storage devices can be found on our website: https://www.supermicro.com/about/policies/disclaimer.cfm?url=/wftp/utility/...
  • Page 4: Table Of Contents

    A+ Server AS -1024US-TRT User's Manual Contents Chapter 1 Introduction 1.1 Overview ..........................8 1.2 Unpacking the System ......................8 1.3 System Features ........................9 1.4 Chassis Features .......................10 Control Panel ........................10 Chassis Front ........................11 Chassis Rear ........................12 1.5 Motherboard Layout ......................13 Quick Reference .......................14 System Block Diagram ......................15 1.6 Where to Get Replacement Components ................16 1.7 Returning Merchandise for Service ..................16...
  • Page 5 Contents Chapter 3 Maintenance and Component Installation 3.1 Removing Power ........................25 3.2 Accessing the System ......................25 3.3 Motherboard Components ....................26 Processor and Heatsink Installation ..................26 Memory Installation ......................34 Memory Support ......................34 DIMM Module Population Sequence ................34 Installing Memory ......................36 Motherboard Battery ......................37 3.4 Chassis Components ......................38 Storage Drives ........................38 Cable Routing ........................40...
  • Page 6 A+ Server AS -1024US-TRT User's Manual 5.3 SuperDoctor 5 ........................63 ® 5.4 BMC ............................64 BMC ADMIN User Password ....................64 Chapter 6 UEFI BIOS 6.1 Introduction .........................65 Starting BIOS Setup Utility ....................65 6.2 Main Setup .........................65 6.3 Advanced Setup Configurations ..................67 6.4 IPMI ...........................
  • Page 7 Super Micro Computer, Inc. 980 Rock Ave. San Jose, CA 95131 U.S.A. Tel: +1 (408) 503-8000 Fax: +1 (408) 503-8008 Email: marketing@supermicro.com (General Information) support@supermicro.com (Technical Support) Website: www.supermicro.com Europe Address: Super Micro Computer B.V. Het Sterrenbeeld 28, 5215 ML...
  • Page 8: Overview

    Introduction 1.1 Overview The Supermicro AS -1024US-TRT A+ is a high-end enterprise server well suited for Virtualization and Cloud Computing with flexible networking options. It is based on the H12DSU-iN motherboard and the 819UTS-R1K02P-A chassis. This chapter provides a brief outline of the functions and features.
  • Page 9: System Features

    Chapter 1: Introduction 1.3 System Features The following is an overview of the main features. System Features Motherboard H12DSU-iN Chassis 819UTS-R1K02P-A Dual AMD EPYC 7003/7002 series in SP3 sockets (7003 Series Processor drop-in support requires BIOS version 2.0 or newer) Chipset System on Chip Memory...
  • Page 10: Chassis Features

    A+ Server AS -1024US-TRT User's Manual 1.4 Chassis Features Control Panel Power switches and status LEDs are located on the control panel on the front of the chassis. Figure 1-1. Control Panel Control Panel Features Item Features Description The main power switch applies or removes primary power from the power supply to Power button the server but maintains standby power.
  • Page 11: Chassis Front

    Chapter 1: Introduction Chassis Front The illustration below shows the features included on the front of the chassis. Storage drive carriers display status lights. Figure 1-2. Front View Chassis Front Features Item Features Description Control Panel see previous page Storage Drives Four 3.5"...
  • Page 12: Chassis Rear

    A+ Server AS -1024US-TRT User's Manual Chassis Rear The illustration below shows the features included on the rear of the chassis. Power supply modules display status lights. Figure 1-4. Rear View Chassis Rear Features Item Features Description Power Supply Two power supply modules, PWS1 on the left, PWS2 on the right Two 10GBase-T ports Two USB 3.0 ports IPMI LAN...
  • Page 13: Motherboard Layout

    Chapter 1: Introduction 1.5 Motherboard Layout Below is a layout of the H12DSU-iN with jumper, connector and LED locations shown. See the table on the following page for descriptions. For detailed descriptions, pinout information and jumper settings, refer to Chapter 4. IPMI_LAN COM1 USB0/1 (3.0)
  • Page 14: Quick Reference

    A+ Server AS -1024US-TRT User's Manual Quick Reference Jumper Description Default Setting JBT1 CMOS Clear Open (Normal) JWD1 Watch Dog Pins 1-2 (Reset) Connector Description JIPMB1 4-pin External I C Header (for an IPMI card) Onboard Battery VGA Port UID_SW UID Switch COM1 COM Port...
  • Page 15: System Block Diagram

    Chapter 1: Introduction System Block Diagram System Block Diagram – AS -1024US-TRT 16 DDR4 DIMM Slots 16 DDR4 DIMM Slots EPYC xGMi2 x4 AMD EPYC PCI-E x32 (CPU1) WIO LR Riser Slot PCI-E x40 Ultra Riser Slot (32 PCI-E Lanes) (40 PCI-E Lanes) WIO LH Riser Card WIO RH Riser Slot...
  • Page 16: Where To Get Replacement Components

    For faster service, RMA authorizations may be requested online (http://www.supermicro.com/ support/rma/). Whenever possible, repack the chassis in the original Supermicro carton, using the original packaging material. If these are no longer available, be sure to pack the chassis securely, using packaging material to surround the chassis so that it does not shift within the carton and become damaged during shipping.
  • Page 17: Chapter 2 Server Installation

    Chapter 2: Server Installation Chapter 2 Server Installation 2.1 Overview This chapter provides advice and instructions for mounting your system in a server rack. If your system is not already fully integrated with processors, system memory etc., refer to Chapter 4 for details on installing those specific components. Caution: Electrostatic Discharge (ESD) can damage electronic components.
  • Page 18: Server Precautions

    SuperServer AS -1024US-TRT User's Manual • In single rack installations, stabilizers should be attached to the rack. In multiple rack in- stallations, the racks should be coupled together. • Always make sure the rack is stable before extending a server or other component from the rack.
  • Page 19: Circuit Overloading

    Chapter 2: Server Installation Circuit Overloading Consideration should be given to the connection of the equipment to the power supply circuitry and the effect that any possible overloading of circuits might have on overcurrent protection and power supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern.
  • Page 20: Installing The Rails

    SuperServer AS -1024US-TRT User's Manual 2.3 Installing the Rails There are a variety of rack units on the market, which may require a slightly different assembly procedure. This rail set fits a rack between 25.6" and 33" deep. The following is a basic guideline for installing the system into a rack with the rack mounting hardware provided.
  • Page 21: Installing The Outer Rails Onto The Rack

    Chapter 2: Server Installation Installing the Outer Rails onto the Rack Each end of the assembled outer rail includes a bracket with square pegs to fit into your rack holes. If you have an older rack with round holes, these brackets must be removed, and you must use screws to secure the rail to the rack.
  • Page 22: Installing The Chassis Into A Rack

    SuperServer AS -1024US-TRT User's Manual 2.4 Installing the Chassis into a Rack Once rails are attached to the chassis and the rack, you can install the server. 1. Pull the middle rail out of the front of the outer rail and make sure that the ball bearing shuttle is locked at the front of the middle rail.
  • Page 23: Removing The Chassis From The Rack

    Chapter 2: Server Installation Removing the Chassis from the Rack Caution! It is dangerous for a single person to off-load the heavy chassis from the rack without assistance. Be sure to have sufficient assistance supporting the chassis when removing it from the rack.
  • Page 24: Installing The Server Into A Telco Rack

    SuperServer AS -1024US-TRT User's Manual Installing the Server into a Telco Rack To install the server into a Telco (or “open”) type rack, use L-shaped brackets (p/n MCP-290- 00016-0N) on either side of the chassis (four total). Note that this is only recommended for 1U systems.
  • Page 25: Chapter 3 Maintenance And Component Installation

    Chapter 3: Maintenance and Component Installation Chapter 3 Maintenance and Component Installation This chapter provides instructions on installing and replacing main system components. To prevent compatibility issues, only use components that match the specifications and/or part numbers given. Installation or replacement of most components require that power first be removed from the system.
  • Page 26: Motherboard Components

    A+ Server AS -1024US-TRT User's Manual Release Buttons Figure 3-1. Removing the Chassis Cover 3.3 Motherboard Components Processor and Heatsink Installation Cautions: • When handling the processor (CPU) package, avoid placing direct pressure on the label area of the CPU or CPU socket. •...
  • Page 27 CPU socket cap is in place and none of the socket pins are bent; otherwise, contact your retailer immediately. • Refer to the Supermicro website for updates on CPU support. Installing the Processor and Heatsink Begin by removing power from the system as described in Section 3.1.
  • Page 28 A+ Server AS -1024US-TRT User's Manual 2. The spring-loaded Force Frame will raise up after the last screw (#1) is removed. Gently allow it to lift up to its stopping position. Figure 3-3. Raising the Force Frame 3. Lift the Rail Frame up by gripping the lift tabs near the front end of the rail frame. While keeping a secure grip of the Rail Frame, lift it to a position so you can do the next step of removing the External Cap.
  • Page 29 Chapter 3: Maintenance and Component Installation 4. Remove the External Cap from the Rail Frame by pulling it upwards through the rail guides on the Rail Frame. External Cap PnP Cover Cap Figure 3-5. Removing the External Cap 5. The CPU Package is shipped from the factory with the blue Carrier Frame pre- assembled.
  • Page 30 A+ Server AS -1024US-TRT User's Manual Note: You can only install the CPU inside the socket in one direction with the handle at the top. Make sure that it is properly inserted into the CPU socket before closing the Rail Frame plate.
  • Page 31 Chapter 3: Maintenance and Component Installation Figure 3-8. Securing the Force Frame 10. Replace the screws in the order 1-2-3, tightening to 16.1 kgf-cm (14 lbf-in) of torque. The Force Frame secures both the Rail Frame and CPU Package. Caution: Tightening must be executed in proper 1-2-3 sequence to avoid causing catastrophic damage to the socket or CPU Package.
  • Page 32 A+ Server AS -1024US-TRT User's Manual 11. Lower the heatsink down till it rests securely on CPU Package over the four screw holes on the socket frame. Figure 3-10. Mounting the Heatsink 12. Using a diagonal pattern and a Torx T20 driver, tighten the four heatsink screws evenly to 16.1 kgf-cm (14.0 lbf-in) of torque.
  • Page 33 Chapter 3: Maintenance and Component Installation Removing a Heatsink We do not recommend removing the heatsink. If necessary, please follow the instructions below to prevent damage to the CPU or the CPU socket. Note: Wait for the heatsink to cool down before removing it. 1.
  • Page 34: Memory Installation

    Memory Installation Memory Support The H12DSU-iN supports Up to 8 TB of ECC DDR4 3200 MHz speed, RDIMM/LRDIMM/3DS/ NVDIMM memory in thirty-two slots. Check the Supermicro website for possible updates to memory support. Processors and their Corresponding Memory Modules CPU#...
  • Page 35 Chapter 3: Maintenance and Component Installation Populating RDIMM/RDIMM 3DS/LRDIMM/LRDIMM 3DS DDR4 Memory Modules Maximum DIMM DIMM Population Maximum Frequency Capacity (GB) Type (MHz) DIMM1 DIMM2 1 Channel 8 Channel 32GB 256GB 3200 64GB 512GB 2933 RDIMM 2R or 2DR 64GB 512GB 3200 2R or 2DR...
  • Page 36: Installing Memory

    A+ Server AS -1024US-TRT User's Manual Installing Memory ESD Precautions Electrostatic Discharge (ESD) can damage electronic com ponents including memory modules. To avoid damaging DIMM modules, it is important to handle them carefully. The following measures are generally sufficient. • Use a grounded wrist strap designed to prevent static discharge.
  • Page 37: Motherboard Battery

    Chapter 3: Maintenance and Component Installation Motherboard Battery The motherboard uses non-volatile memory to retain system information when system power is removed. This memory is powered by a lithium battery residing on the motherboard. Replacing the Battery Begin by removing power from the system as described in section 3.1. 1.
  • Page 38: Chassis Components

    Blinking at 4 Hz Identify drive with RSTe support Green Solid On Safe to remove NVMe device Amber Blinking at 1 Hz Attention state—do not remove NVMe device Note: Enterprise level drives are recommended. For information, visit https://www.supermicro. com/en/Aplus/system/1U/1024/AS-1024US-TRT.cfm.
  • Page 39 Chapter 3: Maintenance and Component Installation Removing a Hot-Swap Drive Carrier from the Chassis 1. Press the release button on the drive carrier, which will extend the drive carrier handle. 2. Use the drive carrier handle to pull the drive out of the chassis. Figure 3-14.
  • Page 40: Cable Routing

    A+ Server AS -1024US-TRT User's Manual Installing a Drive 1. Remove the dummy drive, which comes pre-installed in the drive carrier, by removing the screws securing the dummy drive to the carrier. These screws are not used to mount the actual hard drive. Dummy Drive Drive Carrier Figure 3-15.
  • Page 41: System Cooling

    Chapter 3: Maintenance and Component Installation System Cooling Eight 4-cm counter-rotating fans provide the cooling for the system. Each fan unit is actually made up of two fans joined back-to-back, which rotate in opposite directions. This counter- rotating action generates exceptional airflow and works to dampen vibration levels. Make sure the chassis top cover makes a good seal so the cooling air circulates properly through the chassis.
  • Page 42: System Fan Replacement

    3. Unplug the fan cable from the motherboard and remove the failed fan from the chassis. 4. Replace the failed fan with an identical 4cm fan, available from Supermicro. 5. Push the new fan into the vacant space in the housing while making sure the arrows on the top of the fan (indicating air direction) point in the same direction as the arrows on the other fans.
  • Page 43: Installing The Air Shroud

    Chapter 3: Maintenance and Component Installation Installing the Air Shroud Air shrouds concentrate airflow to maximize fan efficiency. The motherboard air shroud does not require screws to install. Installing the Air Shroud • Lower the air shroud in place, hooking the front tabs over the fan housings. Figure 3-18.
  • Page 44: Checking The Server Air Flow

    A+ Server AS -1024US-TRT User's Manual Checking the Server Air Flow • Make sure there are no objects to obstruct airflow in and out of the server. • Do not operate the server without drives or drive carriers in the drive bays. •...
  • Page 45: Power Supply

    • Solid Amber: When illuminated, indicates that the power supply is plugged in, and is in an abnormal state. The system might need service. Please contact Supermicro technical support. Changing the Power Supply Module: 1. Unplug the AC cord from the module to be replaced.
  • Page 46: Pci Expansion Cards

    (CPU2) Full-height, full-length x16 (CPU2) Full-height = 4.2", Low-profile = 2.5", Full-length = 10.5", Half-length = 6.6" * This is a proprietary slot and supports certain Supermicro devices. Contact your Supermicro sales rep or Technical Support for more details.
  • Page 47 Chapter 3: Maintenance and Component Installation Installing an Expansion Card 1. Power down the system as described in section 3.1 and remove the cover. 2. Remove the bracket and sections of the chassis in the rear. Small screwdriver icons are etched into the chassis pieces to help identify which screws must be removed.
  • Page 48 A+ Server AS -1024US-TRT User's Manual Expansion Cards Internal Expansion Card Figure 3-23. Expansion cards Installed Installing the Internal Expansion Card 1. Remove the cover. 2. Locate the mounting bracket in the accessories box. Mount the bracket to hold the SAS expansion card onto the Ultra riser card.
  • Page 49: Removing The Ultra Riser Card

    Chapter 3: Maintenance and Component Installation Removing the Ultra Riser Card To remove the Ultra riser card, use two hands. One hand lifts the mylar release tab and the other hand lifts at the PCIe x8 slot at the same time. Caution: Lifting at only one of these points may cause damage to connectors on the motherboard.
  • Page 50: Chapter 4 Motherboard Connections

    A+ Server AS -1024US-TRT User's Manual Chapter 4 Motherboard Connections This section describes the connections, jumpers and LED indicators on the motherboard and provides pinout definitions. Not all connections are required. A motherboard layout indicating component locations may be found in Chapter 1. Please review the Safety Precautions in appendix B before installing or removing components.
  • Page 51: Headers And Connectors

    Chapter 4: Motherboard Connections 4.2 Headers and Connectors The data cables in the system have been carefully routed to maintain airflow efficiency. If you disconnect any of these cables, take care to re-route them as they were originally. Important! Make sure the the cables do not come into contact with the fans. Fan Headers There are eight fan headers on the motherboard.
  • Page 52 The JTPM1 header is used to connect a Trusted Platform Module (TPM), which is available from Supermicro. A TPM is a security device that supports encryption and authentication in hard drives. It enables the motherboard to deny access if the TPM associated with the hard drive is not installed in the system.
  • Page 53: Control Panel

    Control Panel JF1 contains header pins for various control panel connections designed specifically for use with Supermicro chassis. See the figure below for the pin locations and definitions of the control panel buttons and LED indicators. All JF1 wires have been bundled into a single cable to simplify this connection. Make sure the red wire plugs into pin 1 as marked on the motherboard.
  • Page 54 A+ Server AS -1024US-TRT User's Manual Power Button The Power Button connection is located on pins 1 and 2 of JF1. Momentarily contacting both pins will power on/off the system. This button can also be configured to function as a suspend button with a setting in the BIOS.
  • Page 55 Chapter 4: Motherboard Connections NIC1/NIC2 (LAN1/LAN2) The NIC (Network Interface Controller) LED connection for LAN port 1 is located on pins 11 and 12 of JF1, and the LED connection for LAN Port 2 is on Pins 9 and 10. Attach the NIC LED cables here to display network activity.
  • Page 56: Ports

    A+ Server AS -1024US-TRT User's Manual 4.3 Ports See the figure below for the locations and descriptions of the various I/O ports on the rear of the motherboard. Figure 4-2. Rear I/O Ports Rear I/O Ports Description Description USB 0/1 Ports UID button and LED IPMI LAN Port VGA Port...
  • Page 57: Jumpers

    Chapter 4: Motherboard Connections 4.4 Jumpers Explanation of Jumpers To modify the operation of the motherboard, jumpers are used to choose between optional settings. Jumpers create shorts between two pins to change the function associated with it. Pin 1 is identified with a square solder pad on the printed circuit board. See the motherboard layout page for jumper locations.
  • Page 58 A+ Server AS -1024US-TRT User's Manual Watch Dog JWD1 controls the Watch Dog function. Watch Dog is a monitor that can reboot the system when a software application hangs. Jumping pins 1-2 will cause Watch Dog to reset the system if an application hangs.
  • Page 59: Led Indicators

    Chapter 4: Motherboard Connections 4.5 LED Indicators LAN LEDs The LAN ports are located on the I/O back panel on the motherboard. Each Ethernet LAN port has two LEDs. The yellow LED indicates activity. Link LED, located on the left side of the LAN port, may be green, amber or off indicating the speed of the connection.
  • Page 60: Chapter 5 Software

    1. Create a method to access the MS Windows installation ISO file. That can be a USB flash or media drive. 2. Go to the Supermicro web page for your motherboard and click on "Download the Latest Drivers and Utilities", select the proper driver, and copy it to a USB flash drive.
  • Page 61 Chapter 5: Software 4. During Windows Setup, continue to the dialog where you select the drives on which to install Windows. If the disk you want to use is not listed, click on “Load driver” link at the bottom left corner. Figure 5-2.
  • Page 62: Driver Installation

    SuperServer AS -1024US-TRT User's Manual 5.2 Driver Installation The Supermicro website contains drivers and utilities for your system at www.supermicro.com/ wdl/driver/AMD/SP3. Some of these must be installed, such as the chipset driver. After accessing the website, go into the CDR_Images (in the parent directory of the above link) and locate the ISO file for your motherboard.
  • Page 63: Superdoctor 5

    5.3 SuperDoctor ® The Supermicro SuperDoctor 5 is a program that functions in a command-line or web-based interface for Windows and Linux operating systems. The program monitors such system health information as CPU temperature, system voltages, system power consumption, fan speed, and provides alerts via email or Simple Network Management Protocol (SNMP).
  • Page 64: Bmc

    There are several BIOS settings that are related to BMC. For general documentation and information on BMC, visit our website at: www.supermicro.com/en/solutions/management-software/bmc-resources BMC ADMIN User Password For security, each system is assigned a unique default BMC password for the ADMIN user.
  • Page 65: Chapter 6 Uefi Bios

    Chapter 6: BIOS Chapter 6 UEFI BIOS 6.1 Introduction This chapter describes the AMI BIOS setup utility for the H12DSU-iN and provides the instructions on navigating the setup screens. The BIOS is stored in a Flash EEPROM and can be updated. Note: Due to periodic changes to the BIOS, some settings may have been added or deleted since this manual was published.
  • Page 66 HH:MM:SS format. Note: The time is in the 24-hour format. For example, 5:30 P.M. appears as 17:30:00. The date's default value is 01/01/2016 after RTC reset. Supermicro H12DSU-iN (Motherboard model) BIOS Version Build Date (of the BIOS) CPLD (Complex Programmable Logic Device) Version: This item displays the CPLD version used in the system.
  • Page 67: Advanced Setup Configurations

    Chapter 6: BIOS 6.3 Advanced Setup Configurations Use the arrow keys to select the Advanced tab and press <Enter> to access the submenu items. Caution: Take caution when changing the Advanced settings. An incorrect value, a very high DRAM frequency, or an incorrect DRAM timing setting may make the system unstable. If this occurs, revert to the manufacture default settings.
  • Page 68 A+ Server AS -1024US-TRT User's Manual Wait For "F1" If Error Use this feature to force the system to wait until the 'F1' key is pressed if an error occurs. The options are Disabled and Enabled. INT19 (Interrupt 19) Trap Response Interrupt 19 is the software interrupt that handles the boot disk function.
  • Page 69 Chapter 6: BIOS PSP Firmware Versions  This section displays the Platform Security Processor (PSP) firmware versions. PSP Directory Level 1 (Fixed) • PSP Recovery BL Ver • SMU FW Version • ABL Version PSP Directory Level 2 (Updateable) • PSP Bootloader Version •...
  • Page 70 A+ Server AS -1024US-TRT User's Manual Device Settings This item displays the status of a serial part specified by the user. Change Settings This feature specifies the base I/O port address and the Interrupt Request address of a serial port specified by the user. Select Auto to allow the BIOS to automatically assign the base I/O and IRQ address.
  • Page 71 Chapter 6: BIOS Bits per second Use this feature to set the transmission speed for a serial port used in Console Redirection. Make sure that the same speed is used in the host computer and the client computer. A lower transmission speed may be required for long and busy lines. The options are 9600, 19200, 38400, 57600 and 115200 (bits per second).
  • Page 72 A+ Server AS -1024US-TRT User's Manual Putty KeyPad This feature selects the settings for Function Keys and KeyPad used for Putty, which is a terminal emulator designed for the Windows OS. The options are VT100, LINUX, XTERMR6, SC0, ESCN, and VT400. Redirection After BIOS POST For this setting, when the Bootloader is selected, then the Legacy Console Redirection is disabled before booting to the legacy OS.
  • Page 73 Chapter 6: BIOS as a parity bit to be sent along with the data bits. Select Space to add a Space as a parity bit to be sent with your data bits. The options are None, Even, Odd, Mark, and Space. Stop Bits A stop bit indicates the end of a serial data packet.
  • Page 74 A+ Server AS -1024US-TRT User's Manual Serial Port for Out-of-Band Management/Windows Emergency Management Services (EMS) Console Redirection Select Enabled to enable EMS console redirection support for a serial port specified by the user. The options are Enabled and Disabled. *If the item above set to Enabled, the following items will become available for user's configuration: ...
  • Page 75 Chapter 6: BIOS as a parity bit to be sent along with the data bits. Select Space to add a Space as a parity bit to be sent with your data bits. The options are None, Even, Odd, Mark, and Space. Stop Bits A stop bit indicates the end of a serial data packet.
  • Page 76 A+ Server AS -1024US-TRT User's Manual CPU1/CPU2 Information  These sections are for informational purposes. They will display some details about the detected CPUs on the motherboard, such as: • CPU Version • Number of Cores Running • Processor Family •...
  • Page 77 Chapter 6: BIOS Memory Configuration  Memory Clock This setting allows you to select different memory clock speed. Options include Auto and speed settings from 2666Mhz, 2933MHz to 3200MHz. Memory Interleaving This setting controls fabric level memory interleaving. Note that the channel, die and socket have requirements on memory populations and it will be ignored if the memory doesn't support the selected option.
  • Page 78 A+ Server AS -1024US-TRT User's Manual SR-IOV Support If the system has SR-IOV capable PCI-E devices, this setting will Enable or Disable the Single Root IO Virtualization Support for the system. BME DMA Mitigation Re-enable Bus Master Attribute disabled during Pci enumeration for PCI Bridges after SMM Locked.
  • Page 79 Chapter 6: BIOS Network Stack This setting allows you to Enable or Disable the UEFI Network Stack. IPv4 PXE Support This setting allows you to Enable or Disable IPv4 PXE boot support. If disabled, IPv4 PXE boot support will not be available. IPv4 HTTP Support This setting allows you to Enable or Disable IPv4 HTTP boot support.
  • Page 80 A+ Server AS -1024US-TRT User's Manual Port 60/64 Emulation Select Enabled for I/O port 60h/64h emulation support, which in turn, will provide complete legacy USB keyboard support for the operating systems that do not support legacy USB devices.The options include Disabled and Enabled. SATA Configuration This section displays the detected SATA devices installed on the system.
  • Page 81 Chapter 6: BIOS Network Configuration iSCSI Configuration  iSCSI Initiator Name This feature allows the user to enter the unique name of the iSCSI Initiator in IQN format. Once the name of the iSCSI Initiator is entered into the system, configure the proper settings for the following items.
  • Page 82 A+ Server AS -1024US-TRT User's Manual Use this feature to enroll to discard all changes and exit TLS settings. Delete Certification  Use this feature to delete certification. RAM Disk Configuration Press <Enter> to add/remove RAM disks. Disk Memory Type Speficifies type of memory to use from available memory pool in system to create a disk.
  • Page 83: Ipmi

    Chapter 6: BIOS 6.4 IPMI Use this tab page to configure Intelligent Platform Management Interface (IPMI) settings. BMC Firmware Revision This item indicates the IPMI firmware revision used in your system. IPMI Status (Baseboard Management Controller) This item indicates the status of the IPMI firmware installed in your system. System Event Log Enabling/Disabling Options SEL Components...
  • Page 84 A+ Server AS -1024US-TRT User's Manual to keep all system event logs after each system reboot. The options are No, Yes, On next reset, and Yes, On every reset. When SEL is Full This feature allows the user to decide what the BIOS should do when the system event log is full.
  • Page 85 Chapter 6: BIOS Gateway IP Address This item displays the Gateway IP address for this computer. This should be in decimal and in dotted quad form (i.e., 172.31.0.1). VLAN This item displays the virtual LAN settings. The options are Disable and Enable. Configure IPv6 Support This section displays configuration features for IPv6 support.
  • Page 86: Event Logs

    A+ Server AS -1024US-TRT User's Manual 6.5 Event Logs Use this tab page to configure Event Log settings. Change SMBIOS Event Log Settings  This feature allows the user to configure SMBIOS Event settings. Enabling/Disabling Options SMBIOS Event Log Select Enabled to enable SMBIOS (System Management BIOS) Event Logging during system boot.
  • Page 87 Chapter 6: BIOS When Log is Full Select Erase Immediately to immediately erase all errors in the SMBIOS event log when the event log is full. Select Do Nothing for the system to do nothing when the SMBIOS event log is full. The options are Do Nothing and Erase Immediately. SMBIOS Event Log Standard Settings Log System Boot Event Select Enabled to log system boot events.
  • Page 88: Security

    A+ Server AS -1024US-TRT User's Manual 6.6 Security Use this tab page to configure Security settings. Administrator Password Press <Enter> to create a new, or change an existing Administrator password. Note that if the Administrator Password is erased, the User Password will be cleared as well. User Password Press Enter to create a new, or change an existing User password.
  • Page 89 Chapter 6: BIOS Secure Boot Mode Use this item to select the secure boot mode. The options are Standard and Custom. CSM Support Select Enabled to support the EFI Compatibility Support Module (CSM), which provides compatibility support for traditional legacy BIOS for system boot. The options are Disabled and Enabled.
  • Page 90 A+ Server AS -1024US-TRT User's Manual Restore DB defaults  Select Yes to restore all DBs to the default settings. The options are Yes and No. Platform Key (PK)  Details Select this feature to view the details of the Platform Key. Export Select Yes to export a PK from a file on an external media.
  • Page 91 Chapter 6: BIOS Append Select Yes to add the db from the manufacturer's defaults list to the existing db. Select No to load the db from a file. The options are Yes and No. Delete Select Ok to remove the db and then the system will reset to Setup/Audit Mode. Forbidden Signatures ...
  • Page 92 A+ Server AS -1024US-TRT User's Manual Append Key Select Yes to add the DBT from the manufacturer's defaults list to the existing DBT. Select No to load the DBT from a file. The options are Yes and No.  OsRecovery Signature The options are Update and Append.
  • Page 93: Boot

    Chapter 6: BIOS 6.7 Boot Use this tab page to configure Boot Settings. Boot Mode Select Use this item to select the type of device that the system is going to boot from. The options are Legacy, UEFI, and DUAL. The default setting is DUAL. Legacy to EFI Support This option Disables or Enables the system to boot to an EFI OS after the boot failed from the legacy boot order.
  • Page 94: Save & Exit

    A+ Server AS -1024US-TRT User's Manual 6.8 Save & Exit Use this tab page to configure Save & Exit settings. Discard Changes and Exit Select this option to quit the BIOS Setup without making any permanent changes to the system configuration, and reboot the computer. Select Discard Changes and Exit from the Exit menu and press <Enter>.
  • Page 95 Chapter 6: BIOS Default Options Restore Defaults To set this feature, select Restore Defaults from the Save & Exit menu and press <Enter>. These are factory settings designed for maximum system stability, but not for maximum performance. Save as User Defaults To set this feature, select Save as User Defaults from the Exit menu and press <Enter>.
  • Page 96: Bios Update Using Ipmi

    If necessary, the system BIOS can be updated using IPMI. Documentation on IPMI is available at http://www.supermicro.com/products/nfo/IPMI.cfm. 1. Download the BIOS file using the link on the server web page. Unzip and save it. 2. Access the IPMI web interface. Enter the IP address and log in. The default username and password are ADMIN/ADMIN.
  • Page 97 Chapter 6: BIOS Start Button Verify Date Clear Checkboxes Figure 6-3. Start Upgrade Dialog 6. In the Start Upgrade dialog, make sure the three checkboxes are not checked, and verify the date of the BIOS file you uploaded before proceeding. 7.
  • Page 98: Uefi Bios Recovery

    Warning: Do not upgrade the BIOS unless your system has a BIOS-related issue. Flashing the wrong BIOS can cause irreparable damage to the system. In no event shall Supermicro be liable for direct, indirect, special, incidental, or consequential damages arising from a BIOS update.
  • Page 99 Chapter 6: BIOS 2. While the system is turned off, open the chassis and locate the internal USB 3.0 Type-A port on the motherboard. Insert the USB device that contains the new BIOS binary image, SUPER.ROM.. 3. Power on the system. 4.
  • Page 100 SUPERMICRO BIOS Update: https://www.youtube.com/watch?v=S8z6iOEHGwY • If the BIOS flash recovery fails, contact our RMA Department to have the BIOS chip reprogrammed. This will require shipping the board to Supermicro for repair. Submit your RMA request at https://www.supermicro.com/support/rma. Please follow all...
  • Page 101: Appendix A Standardized Warning Statements For Ac Systems

    Supermicro's Technical Support department for assistance. Only certified technicians should attempt to install or configure components. Read this appendix in its entirety before installing or configuring components in the Supermicro chassis. These warnings may also be found on our website at http://www.supermicro.com/about/...
  • Page 102 Appendix A Standardized Warning Statements for AC Systems Warnung WICHTIGE SICHERHEITSHINWEISE Dieses Warnsymbol bedeutet Gefahr. Sie befinden sich in einer Situation, die zu Verletzungen führen kann. Machen Sie sich vor der Arbeit mit Geräten mit den Gefahren elektrischer Schaltungen und den üblichen Verfahren zur Vorbeugung vor Unfällen vertraut. Suchen Sie mit der am Ende jeder Warnung angegebenen Anweisungsnummer nach der jeweiligen Übersetzung in den übersetzten Sicherheitshinweisen, die zusammen mit diesem Gerät ausgeliefert wurden.
  • Page 103 A+ Server AS -1024US-TRT User's Manual . ٌ ‫ا ك ً ف حالة و ٌ يك أى تتسبب ف اصابة جسذ ة ٌ هذا الزهز ع ٌ خطز !تحذ ز‬ ‫قبل أى تعول عىل أي هعذات،يك عىل علن بالوخاطز ال ا ٌجوة عي الذوائز‬ ٍ...
  • Page 104 Appendix A Standardized Warning Statements for AC Systems Warnung Vor dem Anschließen des Systems an die Stromquelle die Installationsanweisungen lesen. ¡Advertencia! Lea las instrucciones de instalación antes de conectar el sistema a la red de alimentación. Attention Avant de brancher le système sur la source d'alimentation, consulter les directives d'installation. .‫יש...
  • Page 105 A+ Server AS -1024US-TRT User's Manual Warnung Dieses Produkt ist darauf angewiesen, dass im Gebäude ein Kurzschluss- bzw. Überstromschutz installiert ist. Stellen Sie sicher, dass der Nennwert der Schutzvorrichtung nicht mehr als: 250 V, 20 A beträgt. ¡Advertencia! Este equipo utiliza el sistema de protección contra cortocircuitos (o sobrecorrientes) del edificio.
  • Page 106 Appendix A Standardized Warning Statements for AC Systems Power Disconnection Warning Warning! The system must be disconnected from all sources of power and the power cord removed from the power supply module(s) before accessing the chassis interior to install or remove system components. 電源切断の警告...
  • Page 107 A+ Server AS -1024US-TRT User's Manual ‫אזהרה מפני ניתוק חשמלי‬ ‫!אזהרה‬ ‫יש לנתק את המערכת מכל מקורות החשמל ויש להסיר את כבל החשמלי מהספק‬ ‫.לפני גישה לחלק הפנימי של המארז לצורך התקנת או הסרת רכיבים‬ ‫يجب فصم اننظاو من جميع مصادر انطاقت وإ ز انت سهك انكهرباء من وحدة امداد‬ ‫انطاقت...
  • Page 108 Appendix A Standardized Warning Statements for AC Systems Attention Il est vivement recommandé de confier l'installation, le remplacement et la maintenance de ces équipements à des personnels qualifiés et expérimentés. !‫אזהרה‬ .‫צוות מוסמך בלבד רשאי להתקין, להחליף את הציוד או לתת שירות עבור הציוד‬ ‫واملدربيه...
  • Page 109 A+ Server AS -1024US-TRT User's Manual Warnung Diese Einheit ist zur Installation in Bereichen mit beschränktem Zutritt vorgesehen. Der Zutritt zu derartigen Bereichen ist nur mit einem Spezialwerkzeug, Schloss und Schlüssel oder einer sonstigen Sicherheitsvorkehrung möglich. ¡Advertencia! Esta unidad ha sido diseñada para instalación en áreas de acceso restringido. Sólo puede obtenerse acceso a una de estas áreas mediante la utilización de una herramienta especial, cerradura con llave u otro medio de seguridad.
  • Page 110 Appendix A Standardized Warning Statements for AC Systems Battery Handling Warning! There is the danger of explosion if the battery is replaced incorrectly. Replace the battery only with the same or equivalent type recommended by the manufacturer. Dispose of used batteries according to the manufacturer's instructions 電池の取り扱い...
  • Page 111 A+ Server AS -1024US-TRT User's Manual ‫هناك خطر من انفجار يف حالة اسحبذال البطارية بطريقة غري صحيحة فعليل‬ ‫اسحبذال البطارية‬ ‫فقط بنفس النىع أو ما يعادلها مام أوصث به الرشمة املصنعة‬ ‫جخلص من البطاريات املسحعملة وفقا لحعليامت الرشمة الصانعة‬ 경고! 배터리가...
  • Page 112 Appendix A Standardized Warning Statements for AC Systems ¡Advertencia! Puede que esta unidad tenga más de una conexión para fuentes de alimentación. Para cortar por completo el suministro de energía, deben desconectarse todas las conexiones. Attention Cette unité peut avoir plus d'une connexion d'alimentation. Pour supprimer toute tension et tout courant électrique de l'unité, toutes les connexions d'alimentation doivent être débranchées.
  • Page 113 A+ Server AS -1024US-TRT User's Manual Backplane Voltage Warning! Hazardous voltage or energy is present on the backplane when the system is operating. Use caution when servicing. バックプレーンの電圧 システムの稼働中は危険な電圧または電力が、 バックプレーン上にかかっています。 修理する際には注意く ださい。 警告 当系统正在进行时,背板上有很危险的电压或能量,进行维修时务必小心。 警告 當系統正在進行時,背板上有危險的電壓或能量,進行維修時務必小心。 Warnung Wenn das System in Betrieb ist, treten auf der Rückwandplatine gefährliche Spannungen oder Energien auf.
  • Page 114 Appendix A Standardized Warning Statements for AC Systems ‫هناك خطز مه التيار الكهزبايئ أوالطاقة املىجىدة عىل اللىحة‬ ‫عندما يكىن النظام يعمل كه حذ ر ا عند خدمة هذا الجهاس‬ 경고! 시스템이 동작 중일 때 후면판 (Backplane)에는 위험한 전압이나 에너지가 발생 합니다. 서비스...
  • Page 115 A+ Server AS -1024US-TRT User's Manual ‫תיאום חוקי החשמל הארצי‬ !‫אזהרה‬ .‫התקנת הציוד חייבת להיות תואמת לחוקי החשמל המקומיים והארציים‬ ‫تركيب املعدات الكهربائية يجب أن ميتثل للقىاويه املحلية والىطىية املتعلقة‬ ‫بالكهرباء‬ 경고! 현 지역 및 국가의 전기 규정에 따라 장비를 설치해야 합니다. Waarschuwing Bij installatie van de apparatuur moet worden voldaan aan de lokale en nationale elektriciteitsvoorschriften.
  • Page 116 Appendix A Standardized Warning Statements for AC Systems Attention La mise au rebut ou le recyclage de ce produit sont généralement soumis à des lois et/ou directives de respect de l'environnement. Renseignez-vous auprès de l'organisme compétent. ‫סילוק המוצר‬ !‫אזהרה‬ .‫סילוק סופי של מוצר זה חייב להיות בהתאם להנחיות וחוקי המדינה‬ ‫التخلص...
  • Page 117 A+ Server AS -1024US-TRT User's Manual Warnung Gefährlich Bewegende Teile. Von den bewegenden Lüfterblätter fern halten. Die Lüfter drehen sich u. U. noch, wenn die Lüfterbaugruppe aus dem Chassis genommen wird. Halten Sie Finger, Schraubendreher und andere Gegenstände von den Öffnungen des Lüftergehäuses entfernt.
  • Page 118 Verbindungskabeln, Stromkabeln und/oder Adapater, die Ihre örtlichen Sicherheitsstandards einhalten. Der Gebrauch von anderen Kabeln und Adapter können Fehlfunktionen oder Feuer verursachen. Die Richtlinien untersagen das Nutzen von UL oder CAS zertifizierten Kabeln (mit UL/CSA gekennzeichnet), an Geräten oder Produkten die nicht mit Supermicro gekennzeichnet sind.
  • Page 119 ‫.قيرح وأ لطع يف ببستي دق ىرخأ تالوحمو تالباك يأ مادختسا .ميلسلا سباقلاو لصوملا مجح‬ ‫ لبق نم ةدمتعملا تالباكلا مادختسا تادعملاو ةيئابرهكلا ةزهجألل ةمالسلا نوناق رظحي‬UL ‫ وأ‬CSA ‫( ةمالع لمحت يتلاو‬UL/CSA) ‫ لبق نم ةددحملاو ةينعملا تاجتنملا ريغ ىرخأ تادعم يأ عم‬Supermicro.
  • Page 120 사항을 준수하여 제공되거나 지정된 연결 혹은 구매 케이블, 전원 케이블 및 AC 어댑터를 사용하십시오. 다른 케이블이나 어댑터를 사용하면 오작동이나 화재가 발생할 수 있습니다. 전기 용품 안전법은 UL 또는 CSA 인증 케이블 (코드에 UL / CSA가 표시된 케이블)을 Supermicro 가 지정한 제품 이외의 전기 장치에 사용하는 것을 금지합니다. Stroomkabel en AC-Adapter...
  • Page 121: Appendix B System Specifications

    Appendix B: System Specifications Appendix B System Specifications Processors Dual AMD EPYC 7003/7002 series in SP3 type sockets; System on Chip (7003 Series Processor drop-in support requires BIOS version 2.0 or newer) BIOS AMI 256 Mb SPI Flash EEPROM Memory Up to 8 TB of ECC DDR4 3200 MHz speed, RDIMM/LRDIMM/3DS/NVDIMM memory in 32 slots SATA Controller On-chip...
  • Page 122 A+ Server AS -1024US-TRT User's Manual Operating Environment Operating Temperature: 0º to 35º C (50º to 95º F) Non-operating Temperature: -40º to 70º C (-40º to 158º F) Operating Relative Humidity: 8% to 90% (non-condensing) Non-operating Relative Humidity: 5% to 95% (non-condensing) Regulatory Compliance FCC, ICES, CE, VCCI, RCM, UKCA, NRTL, CB Applied Directives, Standards...
  • Page 123: Appendix C Ipmi Crash Dump

    In the event of a processor internal error (IERR) that crashes your system, you may want to provide information to support staff. You can download a crash dump of status information using IPMI. The IPMI manual is available at https://www.supermicro.com/solutions/IPMI.cfm. Check IPMI Error Log 1.
  • Page 124 A+ Server AS -1024US-TRT User's Manual Downloading the Crash Dump File 1. In the IPMI interface, click the Miscellaneous tab, then the Trouble Shooting option. 2. Click the Dump button and wait five minutes for the file to be created. (No confirm ation message will appear.) 3.