Authorisation Via The Enable Input - Mennekes AMTRON Compact 2.0 7,4 Operating And Installation Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 31
Fig. 11: Remove jumper
u Remove the jumper.
12 V DC, 8 mA
Downgrade input
Fig. 12: Schematic circuit diagram: Connection of an
external switching contact (default setting: NC)
u Install external switching contact.
u Strip the cable.
u Strip the conductors 10 mm.
u Connect the conductors to terminals 3 and 4
(XG1).
u Comply with the connection data for the down-
grade input.
1 "4 Technical data" [} 9]
Configuration
The reduced charging current, which is applied
when the switching contact at the downgrade input
is energised, can be set via DIP switches 4 and 5
on bank S2. The charging current is reduced on a
percentage basis depending on the set maximum
charging current.
DIP switch
Percent-
setting (bank
age of
S2)
max. char-
ging cur-
4
5
rent
OFF
OFF
0 %
18
XG1
3
NC
NO
4
Reduced charging
current (example:
max. charging cur-
rent = 10 A)
0 A
DIP switch
Percent-
setting (bank
age of
S2)
max. char-
ging cur-
4
5
rent
OFF
ON
25 %
ON
OFF
50 %
ON
ON
75 %
* At least 6 A are always available for the charging
process. If the calculated reduced charge current is
less than 6 A, it is rounded up.

6.2.2 Authorisation via the enable input

The tasks described in this section may only
be carried out by a qualified electrician.
The product contains an enable input for author-
ising the charging process. A switching contact
must be installed externally and connected to the
enable input for this purpose. The switching contact
can be a key switch (continuous signal) or a push-
button (pulse signal), for example.
Continuous signal (default setting):
Switching contact
status
open
closed
Pulse signal:
The authorisation is released or terminated by
briefly activating the release input of the switching
contact. To change the setting from continuous sig-
nal to pulse signal, the configuration tool is re-
quired.
1 "6.5 Description of the configuration tool"
[} 19]
Reduced charging
current (example:
max. charging cur-
rent = 10 A)
6 A *
6 A *
7.5 A *
Authorisation status
Authorisation has not
occurred
Authorisation is taking
place

Advertisement

Table of Contents
loading

Table of Contents